Pepperl Fuchs UC500-30GM-2EP-IO-V15 Data Sheet

Ultrasonic sensor UC500-30GM-2EP-IO-V15
Model Number
UC500-30GM-2EP-IO-V15
Single head system
Features
• IO-link interface for service and process data
• Programmable via DTM with PACTWARE
• 2 programmable switch outputs
• Selectable sound lobe width
• Synchronization options
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
200
flat surface
150
100 mm x 100 mm
100
50
0
-50
-100
-150
round bar, Ø 25 mm
-200 0 100 200 300 400 500 600 700 800 900 1000 1100
Y
X
Release date: 2017-10-24 12:02 Date of issue: 2017-10-27 191242_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Distance X [mm]
wide sound lobe narrow sound lobe
Technical data
General specifications
Sensing range 30 ... 500 mm Adjustment range 50 ... 500 mm Dead band 0 ... 30 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 380 kHz Response delay minimum : 25 ms
Memory
Non-volatile memory EEPROM Write cycles 100000
Indicators/operating means
LED green solid: Power on
LED yellow 1 solid: Object in evaluation range
LED yellow 2 solid: Object in evaluation range
LED red solid red: Error
Electrical specifications
Operating voltage U No-load supply current I Power consumption P Time delay before availability t
Interface
B
0
0
v
Interface type IO-Link Protocol IO-Link V1.0 Transfer rate Acyclical: typical 240 Bit/s Cycle time min. 13.2 ms Mode COM 2 (38.4 kBaud) Process data witdh 16 bit SIO mode support yes
Input/Output
Input/output type 1 synchronization connection, bidirectional
0 Level 0 ... 1 V 1 Level 4 V ... U Input impedance > 12 k Output rated operating current < 12 mA Pulse length 0.5 ... 300 ms (level 1) Pulse interval 14 ms (level 0)
Synchronization frequency
Common mode operation 70 Hz Multiplex operation ≤ 90 Hz / n , n = number of sensors , n ≤ 10
Output
Output type 2 push-pull (4 in 1) outputs, short-circuit protected, reverse
Rated operating current I Voltage drop U Repeat accuracy 0.1 % of full-scale value
d
e
Switching frequency f 11 Hz Range hysteresis H 1 % of the adjusted operating range (default settings),
Temperature influence 1.5 % from full-scale value (with temperature
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 5-pin Degree of protection IP67 Material
Housing Stainless steel 1.4305 / AISI 303
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 66 g
Factory settings
Output 1 near switch point: 50 mm
Output 2 near switch point: 100 mm
Beam width wide
Compliance with standards and directives
Standard conformity
factory setting: 45 ms
flashing: Standby mode or IO link communication
flashing: Learning function, object detected
flashing: Learning function, object detected
red, flashing: program function, object not detected
10 ... 30 V DC , ripple 10 % 60 mA
SS
1 W 100 ms
B
(factory setting: n = 5 )
polarity protected 200 mA , short-circuit/overload protected 2.5 V
programmable
compensation) 0.2 %/K (without temperature compensation)
TPU Polyamides
far switch point: 500 mm output function: Window mode output behavior: NO contact
far switch point: 250 mm output function: Window mode output behavior: NO contact
1
Ultrasonic sensor UC500-30GM-2EP-IO-V15
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
IEC 60947-5-2:2007 + A1:2012
Dimensions
M30 x 1.5
2
5
56
36
LED
T1 T2
ø7
M12
81
93
Additional Information
Switching output operating modes
1. Switching point mode
NO contact
NC contact
2. Window mode
NO contact
NC contact
3. Hysteresis mode
NO contact
NC contact
4. Retroreflective sensor mode
NO contact
NC contact
Near
switching
point
Far
switching
point
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
1
5
4
2
3
2
L+
1
3
(brown) (white) (blue) (black) (gray)
Sync.
C/Q
Switch output 2
L-
5
4
Release date: 2017-10-24 12:02 Date of issue: 2017-10-27 191242_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2