Pepperl Fuchs UC250-F77-EP-IO-0.2M-V31 Data Sheet

Ultrasonic sensor UC250-F77-EP-IO-0,2M-V31
Model Number
UC250-F77-EP-IO-0,2M-V31
Single head system
Features
• IO-link interface for service and process data
• Programmable via DTM with PACTWARE
• Continuous distance value via IO­Link process data
• Selectable sound lobe width
• Synchronization options
• Temperature compensation
• Push-pull output
Diagrams
Characteristic response curve
Distance Y [mm]
100
flat surface 100 mm x 100 mm
50
0
-50
round bar, Ø 25 mm
-100 0 50 100 150 200 250 300 350 400 450
Distance X [mm]
Y
X
Release date: 2018-07-25 15:49 Date of issue: 2018-07-25 266632-100000_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
wide sound beam medium-sized sound beam narrow sound beam
Technical data
General specifications
Sensing range 20 ... 250 mm Adjustment range 25 ... 250 mm Dead band 0 ... 20 mm Standard target plate 10 mm x 10 mm Transducer frequency approx. 400 kHz Response delay minimum : 8 ms
Sensor cycle time 8 ms (factory setting) ;
Memory
Non-volatile memory EEPROM Write cycles 300000
Indicators/operating means
LED green solid: power on
LED yellow solid: object in evaluation range
LED red solid: error
Electrical specifications
Operating voltage U No-load supply current I Power consumption P Time delay before availability t
Interface
Interface type IO-Link (via C/Q = Pin 4) Device profile Smart Sensor Transfer rate COM 2 (38.4 kBaud) IO-Link Revision 1.1 Min. cycle time 2.3 ms Process data witdh 16 bit SIO mode support yes Device ID 0x300300 (3146496) Compatible master port type A
Input/Output
Input/output type 1 synchronization connection, bidirectional
0 Level 0 ... 1 V 1 Level 2.5 V ... U Input impedance > 22 k Output rated operating current current source < 2.5 mA Pulse length 1 ms with external control, low active
Synchronization frequency
Common mode operation 141 Hz Multiplex operation 141 Hz / n , n = number of sensors , n 10
Output
Output type 1 push-pull (4 in 1) output, short-circuit protected, reverse
Rated operating current I Voltage drop U Repeat accuracy ± 0.1 % of full-scale value Switching frequency f factory setting: 20 Hz programmable max. 45 Hz Range hysteresis H 1 % of the adjusted operating range (default settings),
Temperature influence ± 0.75 % of the end value (with temperature compensation)
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Cable connector M8 x 1 , 4-pin , L = 200 mm Degree of protection IP67 Material
Housing Polycarbonate
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Installation position any position Mass 20.5 g Tightening torque, fastening screws max. 0.2 Nm
Factory settings
Output near switch point: 25 mm
Beam width wide
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
B
0
0
v
e
d
factory setting: 29 ms
programmable to 60 s
flashing: standby mode or IO-Link communication
flashing: switch point programming, object detected
flashing: switch point programming, object not detected
10 ... 30 V DC , ripple 10 %
40 mA 400 mW 300 ms
B
polarity protected 100 mA , short-circuit/overload protected 2.5 V
programmable , min. 1 mm
from 10 minutes after switching on the sensor ; 0,17 %/K (without temperature compensation)
far switch point: 250 mm Output mode: Window mode Output logic: normally open
IEC 60947-5-2:2007 + A1:2012 IEC 61131-9:2013
SS
1
Ultrasonic sensor UC250-F77-EP-IO-0,2M-V31
Approvals and certificates
UL approval cULus Listed, Class 2 Power Source CCC approval CCC approval / marking not required for products rated 36 V
Dimensions
LED YE LED GN/RD
12
31
18
ø 4.3
L
25
ø 3.2
322
23
3.2
3.2
3 14
17
Additional Information
Switching output modes
1. Switch point mode
Switch point 1
(SP 1)
Normally open
Normally closed
2. Window mode
Normally open
Normally closed
3. Hysteresis mode
Normally open
Normally closed
4. Retroreflective mode
Normally open
Normally closed
Switch point 2
(SP 2)
M8 x 1
Electrical Connection
*if not used connect to ground (0V)
Pinout
1
2
4
3
24
13
L+
Synchronization*
C/Q (Switching output/ IO-Link Interface)
L-
Release date: 2018-07-25 15:49 Date of issue: 2018-07-25 266632-100000_eng.xml