Pepperl Fuchs UC2000-30GM-IUR2-V15-B587 Data Sheet

Ultrasonic sensor UC2000-30GM-IUR2-V15-B587
Technical data
General specifications
Sensing range 80 ... 1500 mm Adjustment range 120 ... 1500 mm Dead band 0 ... 80 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 180 kHz
Model Number
UC2000-30GM-IUR2-V15-B587
Single head system
Features
•High chemical resistance
• Analog current and voltage output
• PTFE coated transducer
• Temperature compensation
• PTFE mounting adapter included
Diagrams
Characteristic response curves
1
Angle [degrees]
30
20
10
0
-10
-20
-30
90 80 70 60 50 40
0.0
0.5
1.0
1.5
Distance [m]
Curve 1: flat plate 100 mm x 100 mm Curve 2: round bar, Ø 25 mm
2
2.0 2.5 3.0
Response delay 65 ms minimum
Indicators/operating means
LED green solid: Power-on
LED yellow 1 solid: object in evaluation range
LED yellow 2 solid: object in detection range
LED red solid: temperature/program plug not connected
Temperature/TEACH-IN connector Temperature compensation , Evaluation range programming
Electrical specifications
Operating voltage U Power consumption P
Interface
B
0
Interface type RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation 30 Hz Multiplex operation 30/n Hz, n = number of sensors
Output
Output type 1 current output 4 ... 20 mA
Switch-on delay t Resolution evaluation range [mm]/4000, but 0.35 mm
on
Deviation of the characteristic curve 0.2 % of full-scale value Repeat accuracy 0.1 % of full-scale value Load impedance current output: 500 Ohm
Temperature influence 2 % from full-scale value (with temperature compensation)
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP65 Material
Housing 1.4303 stainless steel
Transducer PTFE coated; epoxy resin/hollow glass sphere mixture;
Mass 170 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
195 ms factory setting
flashing: Standby mode or program function object detected
flashing: program function
flashing: program function
flashing: fault or program function object not detected
, output function setting
10 ... 30 V DC , ripple 10 % 900 mW
0 level -U 1 level: +4 V...+U input impedance: > 12 KOhm synchronization pulse: 100 µs, synchronization interpulse period: 2 ms
...+1 V
B
SS
B
1 voltage output 2 ... 10 V < 150 ms
Voltage output: 1000 Ohm
0.2 %/K (without temperature compensation)
plastic parts PBT Sensor well : PTFE
polyurethane foam
IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003
Release date: 2016-11-07 14:36 Date of issue: 2016-11-07 905069_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ultrasonic sensor UC2000-30GM-IUR2-V15-B587
Dimensions
1½″ NPT
M30
Temperature probe
Coded plug
LED
57
43.5
41
6.5
22
55.5
27.5
120
Additional Information
Analogue output function
Analog function
Near distance
of evaluation
Rising slope
4 mA/0 V
Falling slope
20 mA/10 V
Zero line mode
4 mA/0 V
A1= 0 mm A2
Far distance of evaluation
20 mA/10 V
4 mA/0 V
20 mA/10 V
Electrical Connection
Standard symbol/Connection:
(version IU)
U
Core colors in accordance with EN 60947-5-2.
Pinout
Connector V15
3
1
(BN)
(GY)
5
2
(WH)
(BK)
4
(BU)
3
2
1
5
4
+ U
B
Sync. 0-10 V 4-20 mA
- U
B
Release date: 2016-11-07 14:36 Date of issue: 2016-11-07 905069_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2