Pepperl Fuchs UC1000-18GM90-E2-IO-V1 Data Sheet

Ultrasonic sensor UC1000-18GM90-E2-IO-V1
Technical data
General specifications
Sensing range 100 ... 1000 mm Adjustment range 110 ... 1000 mm Dead band 0 ... 100 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 200 kHz Response delay approx. 100 ms Linearity frontal
Nominal ratings
Linearity error ± 2 mm Temperature drift ± 2.5 %
Model Number
UC1000-18GM90-E2-IO-V1
Single head system
Features
• IO-link interface for service and process data
• Switch output
• Temperature compensation
Description
This ultrasonic sensor is a contactless distance sensor based on the echo run time principle. It is suitable for the detection of solid, liquid or powder sound-reflecting objects. The IO-Link interface makes it ideally suited to applications in which the consistent communication of process, parameter and diagnostic data through to sensor level plays an important role.
Diagrams
Characteristic response curve
Distance Y [m]
0.25
0.20
0.15
0.10
0.05
0.00
-0.05
-0.10
-0.15
-0.20
-0.25
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, Ø 25 mm
2
Y
X
1
Distance X [m]
Time delay before availability t
Limit data
v
Permissible cable length max. 20 m
Indicators/operating means
LED green flashes: IO-Link ON
LED yellow on: object within measuring range
Electrical specifications
Rated operating voltage U Operating voltage U Ripple 10 % No-load supply current I
Interface
e
B
0
Interface type IO-Link
Switching output
Output type 1 switch output PNP, NO SIO mode Operating current I Switching frequency 5 Hz
L
Voltage drop 2 V Off-state current 0.01 mA Switch-on delay 100 ms
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F) Shock resistance 30 g , 11 ms period Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Degree of protection IP67 Material
Housing brass, nickel-plated Transducer epoxy resin/hollow glass sphere mixture; foam
Installation position any position Mass 90 g Mounting max. tightening torque: : 60 Nm
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
CCC approval CCC approval / marking not required for products rated
120 ms
24 V DC 12 ... 30 V DC (including ripple)
50 mA
200 mA , short-circuit/overload protected
polyurethane, cover PBT
IEC 60947-5-2:2007 + A1:2012
36 V
Release date: 2016-02-16 08:16 Date of issue: 2016-02-16 228189_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ultrasonic sensor UC1000-18GM90-E2-IO-V1
Dimensions
M18 x 1
Additional Information
Area definitions
S
MR
min
n
101
90.5
87
65
M12 x 1
4
24
LEDs
Unusable
area
Measuring
range
Sensing range
MR
S
max
f
α
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
1
4
3
2
+U
C/Q
-U
1
3
(brown) (white) (blue) (black)
B
B
4
Release date: 2016-02-16 08:16 Date of issue: 2016-02-16 228189_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...