Ultrasonic sensor UC1000-18GM90A-E2-IO-V1
Technical data
General specifications
Sensing range 100 ... 1000 mm
Adjustment range 110 ... 1000 mm
Dead band 0 ... 100 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 200 kHz
Response delay approx. 100 ms
Linearity lateral
Nominal ratings
Linearity error ≤ ± 2 mm
Temperature drift ≤ ± 2.5 %
Model Number
UC1000-18GM90A-E2-IO-V1
Single head system
Features
• IO-link interface for service and
process data
• Switch output
• Temperature compensation
Description
This ultrasonic sensor is a contactless distance sensor
based on the echo run time principle. It is suitable for
the detection of solid, liquid or powder sound-reflecting
objects. The IO-Link interface makes it ideally suited to
applications in which the consistent communication of
process, parameter and diagnostic data through to
sensor level plays an important role.
Diagrams
Characteristic response curve
Distance Y [m]
0.25
0.20
0.15
0.10
0.05
0.00
-0.05
-0.10
-0.15
-0.20
-0.25
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
2
Y
X
1
Distance X [m]
Time delay before availability t
Limit data
v
Permissible cable length max. 20 m
Indicators/operating means
LED green flashes: IO-Link ON
LED yellow on: object within measuring range
Electrical specifications
Rated operating voltage U
Operating voltage U
Ripple ≤ 10 %
No-load supply current I
Interface
e
B
0
Interface type IO-Link
Switching output
Output type 1 switch output PNP, NO SIO mode
Operating current I
Switching frequency 5 Hz
L
Voltage drop ≤ 2 V
Off-state current ≤ 0.01 mA
Switch-on delay ≤ 100 ms
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Shock resistance 30 g , 11 ms period
Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP67
Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; foam
Installation position any position
Mass 90 g
Mounting max. tightening torque: : 60 Nm
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
CCC approval CCC approval / marking not required for products rated
≤ 120 ms
24 V DC
12 ... 30 V DC (including ripple)
≤ 50 mA
≤ 200 mA , short-circuit/overload protected
polyurethane, cover PBT
IEC 60947-5-2:2007 + A1:2012
≤36 V
Release date: 2016-02-16 08:16 Date of issue: 2016-02-16 228396_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UC1000-18GM90A-E2-IO-V1
Dimensions
M18 x 1
Additional Information
Area definitions
S
MR
min
n
129
101
90.5
87
65
M12 x 1
4
24
LEDs
Unusable
area
Measuring
range
Sensing range
MR
S
max
f
α
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
1
4
3
2
+U
C/Q
-U
1
3
(brown)
(white)
(blue)
(black)
B
B
4
Release date: 2016-02-16 08:16 Date of issue: 2016-02-16 228396_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2

Ultrasonic sensor UC1000-18GM90A-E2-IO-V1
Accessories
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
UVW90-K18
Ultrasonic -deflector
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-G-2M-PUR
Female cordset, M12, 4-pin, PUR cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Description of the sensor functions
The C/Q connection of this sensor provides double function. If the sensor recognizes a connected IO-Link master and receives a communication protocol directly after power
on, the sensor turns into IO-Link communication mode. If the communication protocol is missing after power on, the sensor turns into SIO mode. In this case at this pin a conventional switching signal is provided.
SIO Mode (standard switching output)
Object position Output state
Object in unusable area undefined
Object in sensing range but not in programmed measuring range off
Object in programmed measuring range on
Communication in IO-Link mode
Example parametrization for variable parameters
Process data Object position [mm]
undefined 0 <
-1 100 <
-2 110 <
Object distance [mm] MRn < object distance < MR
-3 MRf < object distance < 1000
-4 unknown object distance
Device ID M18 30 02 00 hex
Informational data (read only) Value range Sub-index
Interne Temperatur: -25 °C ... 105 °C 1
Parameter data (read / write) Value range Sub-index Default value
Start of measuring range MB
end of measuring range MB
Filter depth for averaging 0 ... 255 2 3
n
f
object distance< 100
object distance < 110
object distance < MR
110 mm ... MR
> MRn ... 1000 mm 9/10 1000 mm
n
f
7/8 110 mm
f
Release date: 2016-02-16 08:16 Date of issue: 2016-02-16 228396_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3