Pepperl Fuchs UBE15M-F54-H2-V1 Data Sheet

Ultrasonic sensor, receiver UBE15M-F54-H2-V1
Technical data
General specifications
Sensing range 0 ... 15000 mm , emitter - receiver synchronised Transducer frequency approx. 40 kHz Angle of divergence ± 45 ° at -6 dB
Model Number
UBE15M-F54-H2-V1
Multi-head system
Features
• Large sensing range
• Large possible lateral distance between emitter and receiver
• Separate evaluation
Temperature drift of echo propagation delay
Electrical specifications
Operating voltage U No-load supply current I
Output
Output type 1 pulse output for echo run time, open collector NPN, short-
Ambient conditions
Ambient temperature 0 ... 50 °C (32 ... 122 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Degree of protection IP30 Material
Housing PBT
Mass 110 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
B
0
Dimensions
0.2 %/K
10 ... 30 V DC , ripple 10 % 15 mA (typ. 10 mA at UB = 24 V DC)
circuit proof 0 level (active): U 1 level (inactive): U
IEC 60947-5-2:2007 + A1:2012
SS
2 V, IOL 15 mA
OL
= UB (pull-up R = 330 kOhm)
OH
Diagrams
Direction characteristics
30°
60°
90°
30°
60°
-10 0-20-30
Attenuation (dB)
90°
Bore hole and countersinking for screws/hexagon M4
Electrical Connection
105
94
10
32
21
22
25
3.5 3.5
Release date: 2016-04-18 10:42 Date of issue: 2016-04-18 109086_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Standard symbol/Connection:
Receiver
Core colours in accordance with EN 60947-5-2.
(BN)
1
2
(WH)
3
(BU)
4
(BK)
+ U
nc
- U
Echo
B
B
1
Ultrasonic sensor, receiver UBE15M-F54-H2-V1
Pinout
Connector V1
2
1
3
4
Function
The receiver is part of a complete system consisting of receiver, emitter, and cont­roller
Transmitter UBE15M-F54-H1-V1
Controller: UH3-16E4A-K15-R3
In real mode, the transmitter and receiver will not be not aligned to each other. This reduces the detection range that can be achieved.
The characteristic response curve to the side illustrates examples of the detection range of the system under the following operating conditions.
- The transmitter and receiver are arranged so they lie parallel opposite each other. The graph shows the detection range as a function of lateral offset.
- The receiver is arranged vertically downward, while the emitter is arranged in the direction of the re­ceiver. The graph shows the detection range as a function of the angle of incidence.
This makes it possible to evaluate the detection range of the system as a function of the positioning of the transmitter and receiver for conditions that will occur in practi­cal usage.
Cable sockets with built-in indicator LEDs must not be used to connect this device!
Additional Information
Characteristic response curve
Distance X [m]
15
10
5
0
10 5 -5 -10
Permissible distance (offset) between the optical axis of the emitter and receiver.
Offset Y [m]
Characteristic response curve
15 m 10 m 5 m 5 m 10 m 15 m
30°
45°
60°
Information
Release date: 2016-04-18 10:42 Date of issue: 2016-04-18 109086_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...