Ultrasonic sensor UBC400-18GH40-I-V1
Technical data
General specifications
Sensing range 40 ... 400 mm
Adjustment range 50 ... 400 mm
Dead band 0 ... 40 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 255 kHz
Response delay approx. 100 ms
Electrical specifications
Model Number
UBC400-18GH40-I-V1
Single head system
Features
• Short design, 40 mm
• Analog output 4 mA ... 20 mA
• Measuring window adjustable
• Program input
• Temperature compensation
Diagrams
Characteristic response curves
Distance Y [m]
0.15
Operating voltage U
No-load supply current I
Input
Input type 1 program input
Output
Output type 1 analog output 4 ... 20 mA, short-circuit/overload protected
Resolution 0.4 mm at max. sensing range
Deviation of the characteristic curve ± 1 % of full-scale value
Repeat accuracy ± 0.5 % of full-scale value
Load impedance 0 ... 300 Ohm
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature 0 ... 70 °C (32 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP67
Material
Housing Stainless steel 1.4435 / AISI 316L
Transducer PTFE
Mass 25 g
Factory settings
Output evaluation limit A1: 50 mm
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
B
0
10 ... 30 V DC , ripple 10 %
≤ 20 mA
lower evaluation limit A1: -U
A2: +4 V ... +U
input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s
O-ring for cover seal: Viton
evaluation limit A2: 400 mm
output behavior: rising ramp
IEC 60947-5-2:2007 + A1:2012
EN 60947-5-7:2003
IEC 60947-5-7:2003
B
SS
... +1 V, upper evaluation limit
B
0.10
0.05
0
-0.05
-0.10
-0.15
0 0.2 0.4 0.6 0.8 1.0
Curve 1: flat plate 100 mm x 100 mm
Curve 2: round bar, Ø 8 mm
2
1
Distance X [m]
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
≤36 V
Release date: 2016-02-12 14:49 Date of issue: 2016-02-12 212672_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UBC400-18GH40-I-V1
Dimensions
Additional Information
Programming the analog output mode
Rising ramp
M18 x 1
M12 x 1
10
25
40
53
ø 21
A1 < A2:
Falling ramp
A2 < A1:
A1
A2
object range
A2
A1
Electrical Connection
Standard symbol/Connections:
(version I)
1 (BN)
U
Core colors in accordance with EN 60947-5-2.
2 (WH)
4 (BK)
3 (BU)
+ U
B
Teach input
Analog output
- U
B
Pinout
Connector V1
2
1
3
4
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Adjusting the evaluation limits
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2