
Ultrasonic sensor UBC250-12GM-E5-V1
Technical data
General specifications
Sensing range 30 ... 250 mm
Adjustment range 50 ... 250 mm
Dead band 0 ... 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 310 kHz
Response delay approx. 50 ms
Electrical specifications
Model Number
UBC250-12GM-E5-V1
Features
• High chemical resistance through
PTFE coated transducer surface
• Stainless Steel enclosure
•1 switch output
• Temperature compensation
• Programmable output functions
•Program input
Diagrams
Characteristic response curve
Distance Y [mm]
200
150
100
50
0
-50
-100
-150
-200
0 100 200 300 400 500 600 700 800 900
Y
X
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
12
Distance X [mm]
Operating voltage U
No-load supply current I
Input
Input type 1 program input
Output
Output type 1 switch output PNP Normally open/closed , programmable
Rated operating current I
Default setting Switch point A1: 50 mm Switch point A2: 250 mm
Voltage drop U
Repeat accuracy ≤ 1 %
Switching frequency f ≤ 8 Hz
Range hysteresis H 1 % of the set operating distance
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP68 / IP69K
Material
Housing stainless steel 1.4404 / AISI 316L
Transducer PTFE (diaphragm surface)
Mass 35 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
UL approval cULus Listed, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
e
d
Dimensions
10 ... 30 V DC , ripple 10 %
≤ 30 mA
lower evaluation limit A1: -U
A2: +4 V ... +U
input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s
100 mA , short-circuit/overload protected
≤ 3 V
O-ring for cover seal: Viton
IEC 60947-5-2:2007 + A1:2012
4
17
B
12
43
4
SS
... +1 V, upper evaluation limit
B
65
72.5
Release date: 2017-07-12 08:58 Date of issue: 2017-07-12 197204_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
M12 x 1
ø 7
ø 15
1

Ultrasonic sensor UBC250-12GM-E5-V1
Electrical Connection
Standard symbol/Connections:
(version E5, pnp)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
1 (BN)
2 (WH)
4 (BK)
3 (BU)
2
1
3
(brown)
(white)
(blue)
(black)
+ U
B
Teach input
Switch output
- U
B
4
Additional Information
Programmable output modes
1. Window mode, normally open mode
A1 < A2:
A1
2. Window mode, normally closed mode
A2 < A1:
A2
3. One switch point, normally open mode
A1 -> ∞:
A2
4. One switch point, normally closed mode
A2 -> ∞:
A1
5. A1 -> ∞, A2 -> ∞: Object presence detection mode
Object detected: Switch output closed
No object detected: Switch output open
object distance
A2
A1
Accessories
UB-PROG2
Programming unit
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
BF 12
Mounting flange, 12 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points.
These are set by applying the supply voltage -UB or +UB to the TEACH-IN input. The
supply voltage must be applied to the TEACH-IN input for at least 1 s. Switching
point A1 is taught with -U
, A2 with +UB.
B
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Set target to far switching point
- TEACH-IN switching point A2 with +U
B
TEACH-IN window mode, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
B
2
Release date: 2017-07-12 08:58 Date of issue: 2017-07-12 197204_eng.xml