Ultrasonic sensor
Technical data
General specifications
Sensing range
Adjustment range
Dead band
Standard target plate
Transducer frequency
Response delay
Indicators/operating means
LED green
LED yellow
LED red
Electrical specifications
Operating voltage UB
No-load supply current I0
Input/Output
Synchronization
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Synchronization frequency |
|
Model Number |
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
Common mode operation |
||||||||||||
|
UB800-F12-EP-V15 |
|
|
|
|
|
|
Multiplex operation |
||||||||||||
|
|
|
|
|
|
|
Input |
|||||||||||||
|
Single head system |
|
|
|
|
|
|
Input type |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features |
|
|
|
|
|
|
|
|
|
Pulse length |
|||||||||
|
• Evaluation limits can be taught-in |
|||||||||||||||||||
|
• Selectable sound lobe width |
|
|
Output |
||||||||||||||||
|
|
|
Output type |
|||||||||||||||||
|
• |
Synchronization options |
|
|
Rated operating current Ie |
|||||||||||||||
|
• Very small unusable area |
|
|
Default setting |
||||||||||||||||
|
• |
Temperature compensation |
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage drop Ud |
|
Diagrams |
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
Repeat accuracy |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switching frequency f |
|
Characteristic response curve |
Range hysteresis H |
||||||||||||||||||
|
Temperature influence |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Distance Y [mm] |
|
|
|
|
|
|
|
|
|
Ambient conditions |
|||||||||
200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ambient temperature |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
150 |
|
|
|
flat surface 100 mm x 100 mm |
|
|
|
|
Storage temperature |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mechanical specifications |
100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection type |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Degree of protection |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Material |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Housing |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
-50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Transducer |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
-100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mass |
|||
-150 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
round bar, Ø 25 mm |
|
|
|
|
|
|
|
Compliance with standards and |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
directives |
|||||
0 |
|
200 |
|
400 |
600 |
800 |
1000 |
1200 |
||||||||||||
-200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard conformity |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Distance X [mm] |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
Y |
|
|
|
|
|
|
|
|
|
Standards |
|
<![if ! IE]> <![endif]>eng.xml |
|
|
|
|
|
|
|
|
|
X |
|
|
wide sound lobe |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
narrow sound lobe |
UL approval |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Approvals and certificates |
|||||||
<![if ! IE]> <![endif]>_ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CSA approval |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
<![if ! IE]> <![endif]>202066 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CCC approval |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>-04-25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>Date of issue: 2016 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
<![if ! IE]> <![endif]>-04-25 09:38 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>Release date: 2016 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
UB800-F12-EP-V15
30 ... 800 mm
50 ... 800 mm
0 ... 30 mm
100 mm x 100 mm approx. 310 kHz approx. 100 ms
Operating display
Evaluation range indicator, Ready for programming Ready for programming, Fault
10 ... 30 V DC ≤ 30 mA
1 synchronous connection, bi-directional
0-level: -UB...+1 V
1-level: +4 V...+UB
input impedance: > 12 kΩ
synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms
≤45 Hz
≤45/n Hz, n = number of sensors
1 program input
Switching distance 1: -UB ... +1 V, Switching distance 2: +3 V
... +UB
Input impedance: > 10 kΩ ≥ 1 s
Push-pull output, short-circuit protected, reverse polarity protected
200 mA , short-circuit/overload protected
Switch point A1: 50 mm , Switch point A2: 800 mm , wide sound lobe
≤3 V
≤1 %
6 Hz
1 % of the set operating distance
± 1.5 % of full-scale value
-15 ... 70 °C (5 ... 158 °F) -40 ... 85 °C (-40 ... 185 °F)
Connector M12 x 1 , 5-pin
IP54
Frame: nickel plated, die cast zinc, Laterals: glass-fiber reinforced plastic PC
epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT
60 g
EN 60947-5-2:2007 + A1:2012
IEC 60947-5-2:2007 + A1:2012
cULus Listed, General Purpose
cCSAus Listed, General Purpose
CCC approval / marking not required for products rated ≤36 V
1
Ultrasonic sensor
Dimensions
M4 / 4 deep |
10 |
<![if ! IE]> <![endif]>15 |
|
7.5
1.541.5
|
|
|
|
<![if ! IE]> <![endif]>49 |
<![if ! IE]> <![endif]>32.5 |
|
|
<![if ! IE]> <![endif]>5.3 |
ø4.5 |
|
<![if ! IE]> <![endif]>65 |
<![if ! IE]> <![endif]>2 |
|
|
|
|
5.5 |
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
19.5 |
|
|
M12 x 1 |
|
|
|
|
|
|
|
|
|
|
|
|
24 |
|
Connector 90° adjustable position |
|
|||
|
|
|
|
|
|
|
|
|
|
11.5 |
|
|
N |
normal operation |
|
|
|
|
|
|
|
||
|
A1 |
A2 |
|
|
A1 |
evaluation limit 1 |
|
|
|
|
|
|
<![if ! IE]> <![endif]>IN |
||
|
<![if ! IE]> <![endif]>N |
B |
|
|
A2 |
evaluation limit 2 |
|
|
|
|
|
<![if ! IE]> <![endif]>- |
|||
|
M |
|
|
|
|
|
<![if ! IE]> <![endif]>Teach |
|
|
|
|
|
B |
light beam characteristics |
|
|
|
|
|
|
M |
operating mode |
|
Electrical Connection
Standard symbol/Connections: |
||||
(version EP, pnp/npn) |
|
|||
|
1 |
(BN) |
+ UB |
|
|
2 |
(WH) |
||
U |
TEACH |
|||
5 |
(GY) |
|||
Synchronous |
||||
|
4 |
(BK) |
||
|
Switch output |
|||
|
3 |
(BU) |
||
|
- UB |
|||
|
|
|
||
Core colours in accordance with EN 60947-5-2. |
Pinout
1
5
2 4
3
Wire colors in accordance with EN 60947-5-2
1 |
BN |
(brown) |
2 |
WH |
(white) |
3 |
BU |
(blue) |
4 |
BK |
(black) |
5 |
GY |
(gray) |
2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
UB800-F12-EP-V15
Additional Information
Programmable operation modes
Unusable area
Object distance
1. Switching point mode
N. C.
|
A1 |
|
|
|
||
N. O. |
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
A2 |
|
|
|
||
2. Window mode |
|
|
|
|||
N. O. |
|
|
|
|||
A2 > A1 |
A2 |
|
||||
|
A1 |
|
||||
N. C. |
|
|
|
|||
A1> A2 |
A1 |
|
||||
|
A2 |
|
||||
|
|
|
|
|||
3. Hysteresis mode |
|
|
|
|||
N. C. |
|
|
|
|
|
|
|
|
|
|
|
||
A2 > A1 |
|
|
|
|
|
|
|
A1 |
A2 |
|
|||
N. O. |
|
|
|
|
||
|
|
|
|
|
|
|
A1 > A2 |
|
|
|
|
|
|
|
A2 |
A1 |
|
<![endif]>Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 202066_eng.xml