Ultrasonic sensor UB6000-F42-I-V1-Y220443
Technical data
General specifications
Measurement range 400 ... 6000 mm
Sensing range 350 ... 6000 mm
Dead band 0 ... 350 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 65 kHz
Response delay approx. 650 ms
Indicators/operating means
LED green Power on
LED yellow object in evaluation range
LED red error
Electrical specifications
Model Number
UB6000-F42-I-V1-Y220443
Single head system
Features
•Analog output 4mA...20mA
• Extremely small unusable area
• Temperature compensation
• Synchronization options
Diagrams
Characteristic response curve
Distance Y [m]
3
Flat surface 100 mm x 100 mm
2
1
0
-1
-2
Round bar, Ø 25 mm
-3
0 1 2 3 4 5 6 7 8 9
Y
X
Distance X [m]
Operating voltage U
No-load supply current I
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation ≤ 7 Hz
Multiplex operation ≤ 7/n Hz, n = number of sensors
Output
Output type 1 analog output 4 ... 20 mA
Resolution 0.7 mm
Deviation of the characteristic curve ± 1 % of full-scale value
Repeat accuracy ± 0.1 % of full-scale value
Load impedance 0 ... 300 Ohm
Temperature influence ± 1 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP67
Connection 4-pin, M12 x 1 connector
Material
Housing ABS
Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 330 g
Factory settings
Output evaluation limit A1: 400 mm
Beam width wide sound lobe
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
10 ... 30 V DC , ripple 10 %
≤ 60 mA
0 level -U
1 level: +4 V...+U
input impedance: > 12 KOhm
synchronization pulse: ≥ 100 µs, synchronization interpulse
period: ≥ 2 ms
cover PBT
evaluation limit A2: 6000 mm
rising ramp
IEC 60947-5-2:2007 + A1:2012
EN 60947-5-7:2003
IEC 60947-5-7:2003
...+1 V
B
SS
B
Release date: 2016-04-13 14:01 Date of issue: 2016-04-13 220443_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UB6000-F42-I-V1-Y220443
Dimensions
Membrane keys
16
15.5
LED window
Additional Information
Analogue output programmation
7.5
15
15.5
2
A
TEACH IN
1
MODE SET
A
10
34
52.5
34
M12x1
5
16
5.2
Rising ramp
80
65
56
65
72
80
Unusable area
Object distance
A1A1 A2
Electrical Connection
Standard symbol/Connections:
1 (BN)
U
Core colours in accordance with EN 60947-5-2.
2 (WH)
4 (BK)
3 (BU)
Pinout
Connector V1
2
1
3
4
Accessories
MH 04-3505
Mounting aid for FP and F42 sensors
MHW 11
Mounting brackets for sensors
DA5-IU-2K-V
Process control and indication equipment
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
+ U
B
Sync.
Analogue output
- U
B
Description of Sensor Functions
Synchronization
This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by
applying an external square wave. The pulse duration must be ≥ 100 µs. Each falling edge of the synchronization
pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for ≥ 1 second,
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2