Ultrasonic sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensing range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dead band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard target plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transducer frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response delay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicators/operating means

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating voltage UB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No-load supply current I0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input/Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronization

 

Model Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UB500-F54-U-V15

 

 

 

 

 

 

 

 

 

Single head system

 

 

 

 

 

 

Synchronization frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Common mode operation

 

Features

 

 

 

 

 

 

 

 

 

Multiplex operation

 

• Analog output 0 ... 10 V

 

 

 

 

Input

 

 

 

 

 

Input type

 

Measuring window adjustable

 

 

Program input

 

 

 

 

 

 

 

Output

 

Synchronization options

 

 

 

 

 

 

 

 

 

Output type

 

Deactivation option

 

 

 

 

 

Default setting

 

 

 

 

 

 

Resolution

 

Temperature compensation

 

 

 

Deviation of the characteristic curve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeat accuracy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load impedance

 

Diagrams

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature influence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient conditions

 

Characteristic response curve

Ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage temperature

 

Distance Y [m]

 

 

 

 

 

 

 

 

 

 

 

Mechanical specifications

 

 

0.20

 

 

 

 

 

 

 

 

 

 

 

 

Connection type

 

 

0.15

 

 

 

 

 

 

 

 

 

 

 

 

Degree of protection

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Material

 

 

0.10

 

 

 

 

 

 

 

 

 

 

 

Housing

 

 

0.05

 

 

 

 

 

 

 

 

 

 

 

 

Transducer

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

Mass

 

 

0.00

 

 

 

 

 

 

 

 

 

 

 

 

Compliance with standards and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-0.05

 

 

 

 

 

 

 

 

 

 

 

 

directives

-0.10

 

 

 

 

 

 

 

 

 

 

 

 

Standard conformity

 

 

 

 

 

 

 

 

 

 

 

 

Standards

-0.15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-0.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

 

 

Approvals and certificates

<![if ! IE]>

<![endif]>eng.xml

 

 

 

Y

 

 

 

 

 

Distance X [m]

Curve 1:

flat surface 100 mm x 100 mm

 

 

 

 

UL approval

<![if ! IE]>

<![endif]>_

 

 

 

 

 

X

 

 

 

 

 

 

 

 

EAC conformity

 

Curve 2: round bar, Ø 25 mm

 

 

 

 

 

 

CSA approval

<![if ! IE]>

<![endif]>108158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CCC approval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>-08-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Date of issue: 2016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>-08-01 13:42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Release date: 2016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

UB500-F54-U-V15

30 ... 500 mm

50 ... 500 mm

0 ... 30 mm

100 mm x 100 mm approx. 380 kHz ≤ 50 ms

solid green: monitoring system green flashing: program function

solid yellow: object in the evaluation range yellow, flashing: program function, object detected

flashing:

normal mode: error

Program function: no object detected permanently:

Program mode, object uncertain

15 ... 30 V DC , ripple 10 %SS ≤ 55 mA

1 synchronous input

0 level: UB...+1 V

1 level: +4 V...+UB

input impedance: > 12 KOhm synchronization pulse: 0.1 ... 8 ms

100 Hz

100 / n Hz, n = number of sensors

1 program input

lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB

input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s

1 analog output 0 ... 10 V

evaluation limit A1: 50 mm evaluation limit A2: 500 mm

0.11mm

±1 % of full-scale value

±0.1 % of full-scale value ≥ 1 kOhm

±1.5 % of full-scale value

-25 ... 70 °C (-13 ... 158 °F) -40 ... 85 °C (-40 ... 185 °F)

Connector M12 x 1 , 5-pin

IP65

ABS

epoxy resin/hollow glass sphere mixture; polyurethane foam 100 g

EN 60947-5-2:2007+A1:2012

IEC 60947-5-2:2007 + A1:2012

EN 60947-5-7:2003

IEC 60947-5-7:2003

TR CU 020/2011

cULus Listed, General Purpose

cCSAus Listed, General Purpose

CCC approval / marking not required for products rated ≤36 V

1

Ultrasonic sensor

Dimensions

120

105

94

<![if ! IE]>

<![endif]>21

<![if ! IE]>

<![endif]>32

Bore hole and countersinking for screws/hexagon M4

<![if ! IE]>

<![endif]>3.5

<![if ! IE]>

<![endif]>25

<![if ! IE]>

<![endif]>3.5

Electrical Connection

Standard symbol/Connections:

(version U)

 

1

(BN)

 

+ UB

 

2

(WH)

 

U

 

Teaching input

5

(GY)

 

 

Synchronous

 

4

(BK)

 

 

 

Analog output

 

3

(BU)

 

 

 

- UB

 

 

 

 

 

 

Core colours in accordance with EN 60947-5-2.

Pinout

1

5

2 4

3

Wire colors in accordance with EN 60947-5-2

1

BN

(brown)

2

WH

(white)

3

BU

(blue)

4

BK

(black)

5

GY

(gray)

Accessories

UB-PROG2

Programming unit

V15-G-2M-PVC

Female cordset, M12, 5-pin, PVC cable

2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

UB500-F54-U-V15

Additional Information

Programming the analog output mode

Rising ramp

 

A1 < A2:

object range

 

A1

A2

Falling ramp

 

A2 < A1:

 

A2

A1

<![if ! IE]>

<![endif]>Release date: 2016-08-01 13:42 Date of issue: 2016-08-01 108158_eng.xml