Ultrasonic sensor UB500-F42S-E5-V15
Technical data
General specifications
Sensing range 30 ... 500 mm
Adjustment range 50 ... 500 mm
Dead band 0 ... 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 390 kHz
Response delay approx. 50 ms
Indicators/operating means
LED green solid green: Power on
Model Number
UB500-F42S-E5-V15
Single head system
Features
• Switch output
• Extremely small unusable area
• TEACH-IN
• Interference suppression (adjustable divergence of sound cone in
close range)
• Temperature compensation
• Synchronization options
• NO/NC selectable
Diagrams
Characteristic response curve
Distance Y [m]
0.2
Flat surface 100 mm x 100 mm
0.1
LED yellow solid: switching state switch output
LED red normal operation: "fault"
Electrical specifications
Operating voltage U
No-load supply current I
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation ≤ 95 Hz
Multiplex operation ≤ 95/n Hz, n = number of sensors
Output
Output type 1 switching output E5, PNP NO/NC, programmable
Rated operating current I
Default setting Switch point A1: 50 mm , Switch point A2: 500 mm , wide
Voltage drop U
Repeat accuracy ≤ 0.5 % of switching point
Switching frequency f ≤ 8 Hz
Range hysteresis H 1 % of the set operating distance
Temperature influence ± 1 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP54
Material
Housing ABS
Transducer epoxy resin/hollow glass sphere mixture; foam
Mass 140 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
B
0
e
d
flashing: program function
program function: no object detected
10 ... 30 V DC , ripple 10 %
≤ 50 mA
0 level -U
1 level: +4 V...+U
input impedance: > 12 KOhm
synchronization pulse: ≥ 100 µs, synchronization interpulse
period: ≥ 2 ms
200 mA , short-circuit/overload protected
sound lobe
≤ 2.5 V
polyurethane, cover PBT
IEC 60947-5-2:2007 + A1:2012
...+1 V
B
B
SS
0.0
-0.1
Round bar, Ø 25 mm
-0.2
0.0 0.2 0.4 0.6 0.8 1.0
Y
X
wide sonic beam
narrow sonic beam
Release date: 2016-02-26 11:35 Date of issue: 2016-02-26 133981_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Distance X [m]
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
≤36 V
1

Ultrasonic sensor UB500-F42S-E5-V15
Dimensions
7.5
15
Membrane keys
LED window
2
A
TEACH IN
1
MODE SET
A
10
34
Electrical Connection
Standard symbol/Connections:
(version E5, pnp)
U
Wire colors in accordance with EN 60947-5-2.
15.5
34
52.5
5
1
2
5
4
3
(BN)
(WH)
(GY)
(BK)
(BU)
M12x1
16
+ U
B
Program input
Sync. input
Switch output
- U
B
5.2
Additional Information
Programmable operation modes
Unusable area
Object distance
1. Switching point mode
80
65
65
80
10
N. C.
A2
N. O.
A1
Objectpresence
A1, A2
A1
A2
Detectionlimit
2. Window mode
N. O.
A2 > A1
N. C.
A1> A2
A1
A2 A1
A2
3. Hysteresis mode
N. C.
A2 > A1
N. O.
A1 > A2
Note:
means: cover transducer surface with your hand,
while teaching the switching point.
If A1 = A2, the output works like A2 > A1
A1
A2
A2
A1
Pinout
Connector V15
2
1
3
5
4
Accessories
MH 04-3505
Mounting aid for FP and F42 sensors
MHW 11
Mounting brackets for sensors
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Functional Description
The sensor may be completely parameterised via two keys on the side panel of the
housing. As a special feature provided by this sensor, the ultrasound beam width
may be adapted to the environmental conditions at the place of operation of the sensor.
Specifying the switching points:
When specifying the switching points, the user determines at which points the
switching output changes its state. The order of the switching points A1 > A2, or A1
< A2 also determines the direction of action (i.e. normally-closed/normally-open contact function).
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2