General specifications
Sensing range 30 ... 500 mm Adjustment range 50 ... 500 mm Dead band 0 ... 30 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 390 kHz Response delay approx. 50 ms
Indicators/operating means
LED green solid green: Power on
Model Number
UB500-F42S-E4-V15
Single head system
Features
• Switch output
• Extremely small unusable area
• TEACH-IN
• Interference suppression (adjus­table divergence of sound cone in close range)
• Temperature compensation
• Synchronization options
• NO/NC selectable
Diagrams
Characteristic response curve
Distance Y [m]
0.2
Flat surface 100 mm x 100 mm
0.1
LED yellow solid: switching state switch output
LED red normal operation: "fault"
Electrical specifications
Operating voltage U
No-load supply current I
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation 95 Hz Multiplex operation 95/n Hz, n = number of sensors
Output
Output type 1 switching output E4, NPN, NO/NC, programmable Rated operating current I Default setting Switch point A1: 50 mm , Switch point A2: 500 mm , wide
Voltage drop U Repeat accuracy 0.5 % of switching point Switching frequency f 8 Hz Range hysteresis H 1 % of the set operating distance Temperature influence ± 1 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP54 Material
Housing ABS Transducer epoxy resin/hollow glass sphere mixture; foam
Mass 140 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
B
0
e
d
flashing: program function
program function: no object detected
10 ... 30 V DC , ripple 10 %
50 mA
0 level -U 1 level: +4 V...+U input impedance: > 12 KOhm
synchronization pulse: 100 µs, synchronization interpulse period: 2 ms
200 mA , short-circuit/overload protected
sound lobe 2.5 V
polyurethane, cover PBT
IEC 60947-5-2:2007 + A1:2012
...+1 V
B
B
SS
0.0
-0.1
Round bar, Ø 25 mm
-0.2
0.0 0.2 0.4 0.6 0.8 1.0
Y
X
wide sonic beam narrow sonic beam
Release date: 2016-02-26 11:34 Date of issue: 2016-02-26 133980_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Distance X [m]
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
36 V
1
Ultrasonic sensor UB500-F42S-E4-V15
Dimensions
7.5
15
Membrane keys
LED window
2
A
TEACH IN
1
MODE SET
A
10
34
Electrical Connection
Standard symbol/Connections:
(version E4, npn)
U
Wire colors in accordance with EN 60947-5-2.
15.5
34
52.5
5
1 4 2
5 3
(BN)
(BK)
(WH)
(GY)
(BU)
M12x1
16
+ U
B
Switch output
Program input
Sync. input
- U
B
5.2
Additional Information
Programmable operation modes
Unusable area
Object distance
1. Switching point mode
80
65
65
80
10
N. C. A2
N. O. A1
Object­presence A1, A2
A1
A2
Detection­limit
2. Window mode
N. O. A2 > A1
N. C. A1> A2
A1
A2 A1
A2
3. Hysteresis mode
N. C. A2 > A1
N. O. A1 > A2
Note:
means: cover transducer surface with your hand, while teaching the switching point.
If A1 = A2, the output works like A2 > A1
A1
A2
A2
A1
Pinout
1
5
2
4
3
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
(brown) (white) (blue) (black) (gray)