Ultrasonic sensor
UB500-30GM-E0-V15
Features
• Switch output
• 5 different output functions can be set
• TEACH-IN input
• Synchronisation options
• Deactivation option
Electrical connection
Standard symbol/Connections:
(version E0, npn)
U
1
4
2
5
3
+ U
B
Switch output
Teaching input
Sync. input
- U
B
Dimensions
M30x1.5
5
36
94
22
LED
Technische DatenTechnical data
General specifications
Sensing range 60 ... 500 mm
Unusable area 0 ... 60 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 380 kHz
Response delay approx. 38 ms
Indicators/operating means
LED green "Power on", TEACH-IN function object detected
LED yellow indication of the switching state, TEACH-IN function-no object detected
LED red "Error", object uncertain
Electrical specifications
Operating voltage 20 ... 30 V DC , ripple 10 %
No-load supply current I
Input
Input type 1 TEACH-IN input,
Pulse length Synchronisation pulse: ≥ 100 µs
Synchronisation frequency
Common mode operation ≤ 150 Hz
Multiplex operation ≤ 150/n Hz , n = number of sensors
Output
Output type 1 switch output E0/E1, npn, normally open/closed, programmable
Repeat accuracy ≤ 1 %
Rated operational current I
Voltage drop U
Switching frequency f max. 13 Hz
Range hysteresis H ≤ 1 % of the set operating distance
Temperature influence 0,17 % / K
Standard conformity
Standards EN 60947-5-2
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Protection degree IP65
Connection connector V15 (M12 x 1), 5 pin
Material
Housing brass, nickel-plated, plastic components PBT
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 145 g
d
≤ 60 mA
0
operating distance 1: -U
synchronous input
level 0: -U
Input impedance 27 kOhm
Synchronisation pulse pause: ≥ 100 µs
200 mA , short-circuit/overload protected
e
≤ 3 V
... (-UB + 1 V), level 1: (-UB + 5 V) ... +UB
B
SS
... (-UB +2 V), operating distance 2: (+UB -2 V) ... +UB 1
B
Connector V15
2
1
3
5
4
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
1
Pepperl+Fuchs Group • • • •
2003-03-25 039556_ENG.xml

HinweiseNotes BestellbezeichnungModel number
UB500-30GM-E0-V15
Function
Synchronization
The sensor features a synchronization input for the suppression of mutual interference. It can be synchronized by applying a square wave voltage. The falling edge
of a synchronization pulse at the synchronization input starts a measuring cycle. A
low level > 1 s or an open synchronization input will result in the non-synchronized
normal operation of the sensor. A high level at the synchronization input disables
the sensor. Synchronization cannot be performed during TEACH-IN and vice versa.
Two operating modes are possible:
Characteristic curves/additional
information
Characteristic response curves
90 80 70 60 50 40 30
Angle [degrees]
20
1. The sync. inputs of 2 ... 5 Sensors are connected with each other. The sensors synchronize themselves and operate cyclically (multiplex mode).
2. Multiple sensors can be controlled by the same synchronization signal. The sensors are synchronized.
3. The synchronization pulses are sent cyclically to individual sensors. The sensors operate in multiplex mode.
In case of synchronized operation, the response time of the sensor increases due
to a longer measuring cycle time caused by synchronization.
Note:
If the option for synchronization is not used, the synchronization input has to be connected to ground (0V) or the sensor has to be operated via a V1 cable connector
(4-pin).
Setting the switching points
The ultrasonic sensor features a switch output with two teachable switching points.
These are set by applying the supply voltage -UB or +UB to the TEACH-IN input.
The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with -UB, A2 with +UB.
Five different output functions can be set:
Function TEACH-IN procedure
Window mode,
close function
- Set object to near switching point
- Teach switching point A1 with -UB
- Set object to far switching point
- Teach switching point A2 with +UB
Window mode,
open function
- Set object to near switching point
- Teach switching point A2 with +UB
- Set object to far switching point
- Teach switching point A1 with -UB
1 switching point,
close function
- Set object to near switching point
- Teach switching point A2 with +UB
- Cover sensor or remove all objects from sensing range
- Teach switching point A1 with -UB
1 switching point,
open function
- Set object to near switching point
- Teach switching point A1 with -UB
- Cover sensor or remove all objects from sensing range
- Teach switching point A2 with +UB
Detection of
object presence
- Cover sensor or remove all objects from sensing range
- Teach switching point A1 with -UB
- Teach switching point A2 with +UB
10
0.0
0.1
0.2
0.3
Distance [m]
Curve 1: flat plate 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
2
0.4 0.5 0.6 0.7 0.8
1
0
-10
-20
Programmed switching output function
1. Window mode, normally open function
A1 < A2:
A1
2. Window mode, normally closed function
A2 < A1:
A2
3. One switch point, normally open function
A1 -> ∞:
A2
4. One switch point, normally closed function
A2 -> ∞:
A1
5. A1 -> ∞, A2 -> ∞: Detection of object presence
Object detected: Switch output closed
No object detected: Switch output open
object range
A2
A1
LED-Window
Dual-LED
green/red
"Power on"/Disturbance
LED
yellow
Switch output
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany