Pepperl Fuchs UB500-18GM75-E7-V15 Data Sheet

Ultrasonic sensor UB500-18GM75-E7-V15
Technical data
General specifications
Sensing range 30 ... 500 mm Adjustment range 50 ... 500 mm Dead band 0 ... 30 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 380 kHz Response delay approx. 50 ms
Indicators/operating means
Model Number
UB500-18GM75-E7-V15
Single head system
Features
•2 switch outputs
• 3 different output functions can be set
• Selectable sound lobe width
•Program input
• Temperature compensation
• Very small unusable area
Diagrams
Characteristic response curve
Distance Y [mm]
400
flat surface 100 mm x 100 mm
300
200
100
0
-100
-200
-300
round bar, Ø 25 mm
-400 0 200 400 600 800 1000
Y
X
Distance X [mm]
wide sound lobe narrow sound lobe
LED yellow indication of the switching state
LED red "Error", object uncertain
Electrical specifications
Operating voltage U No-load supply current I
Input
B
0
Input type 1 program input,
Output
Output type 2 switch outputs NPN, normally open/closed , programmable Rated operating current I Voltage drop U Repeat accuracy 1 %
d
e
Switching frequency f max. 8 Hz Range hysteresis H 1 % of the set operating distance Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP67 Material
Housing brass, nickel-plated Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 60 g
Factory settings
Output 1 Switching point: 50 mm
Output 2 Switching point: 500 mm
Beam width wide
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
flashing: program function object detected
in program function: No object detected
10 ... 30 V DC , ripple 10 % 50 mA
operating range 1: -U +U
B
input impedance: > 4.7 k; program pulse: 1 s
SS
... +1 V, operating range 2: +4 V ...
B
2 x 100 mA , short-circuit/overload protected 3 V
cover PBT
output function: Switch point operation mode output behavior: NO contact
output function: Switch point operation mode output behavior: NO contact
IEC 60947-5-2:2007 + A1:2012
Release date: 2016-04-13 11:21 Date of issue: 2016-04-13 130229_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ultrasonic sensor UB500-18GM75-E7-V15
Dimensions
LEDs
4
24
M12 x 1
M18 x 1
Additional Information
Programmed switching output function
1.
Switch output 1 (N.O.)
Switch output 2 (N.O.)
2.
Switch output 2 (N.C.)
Switch output 1
48
75
85
(N.C.)
3.
Switch point 1 -> : Switch output 1, (N.C.)
Switch point 2 -> : Switch output 2, (N.O.)
Switch point 1 a. 2 -> : Both switch outputs, (N.O.)
Switch point
Switch point 2Switch point
1
Switch point
Detection of object presence
Detection of object presence
Detection of object presence
2
object range
1
object range
Electrical Connection
Standard symbol/Connections:
(version E7, npn)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
(BN)
1
(BK)
4 2
(WH)
(GY)
5
(BU)
3
2
+ U
B
Switch output 1
Switch output 2
Teaching input
- U
B
1
5
4
3
(brown) (white) (blue) (black) (gray)
Release date: 2016-04-13 11:21 Date of issue: 2016-04-13 130229_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Ultrasonic sensor UB500-18GM75-E7-V15
Accessories
UB-PROG3
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
UVW90-K18
Ultrasonic -deflector
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
M18K-VE
Description of Sensor Functions
Programming procedure
The sensor features two programmable switch outputs with one programmable switch point, each. Programming the switch point and the oper­ating mode is done by applying the supply voltage -U at least 1 s. LEDs indicate whether the sensor has recognized the target during the programming procedure.
Note:
Switching points may only be specified directly after Power on. A time lock secures the adjusted switching points against unintended modification 5 minutes after Power on. To modify the switching points later, the user may specify the desired values only after a new Power On.
Note:
If a programming adapter UB-PROG3 is used for the programming procedure, button A1 is assigned to -UB and button A2 is assigned to +UB.
Programming switch ouputs
Normally open (NO) output
The switch point of switch output 1 has to be closer to the sensor than the switch point of switch output 2
1. Place the target at the desired switch point position of switch output 1
2. Program the switch point by applying -U
3. Disconnect the Program input from -U
4. Place the target at the desired switch point position of switch output 2
5. Program the switch point by applying +U
6. Disconnect the Program input from +U
Note: The order doesn't make any difference. If you want, you can set only one switching point. Normally closed (NC) output
The switch point of switch output 2 has to be closer to the sensor than the switch point of switch output 1
1. Place the target at the desired switch point position of switch output 1
2. Program the switch point by applying -U
3. Disconnect the Program input from -U
4. Place the target at the desired switch point position of switch output 2
5. Program the switch point by applying +U
6. Disconnect the Program input from +U Note: The order doesn't make any difference. If you want, you can set only one switching point. If both switching points are equal, the sensor works in close function.
Programming detection of object presence
1. Cover the sensor face with hand or remove all objects from sensing range
2. Apply -U
3. Disconnect the Program input from -U
4. Apply +UB to the Program input (red LED flashes)
5. Disconnect the Program input from +U Note: Only one switch output can be configured for detection of presence of objects. If the sensor detects an object within the maximum detection range, the switch output switches.
to the Program input (red LED flashes)
B
to the Program input (corresponding yellow LED flashes)
B
to save the switch point
B
B
to save the switch point
B
to the Program input (corresponding yellow LED flashes)
B
to save the switch point
B
B
to save the switch point
B
B
B
or +UB to the Program input. The supply voltage must be applied to the Program input for
B
to the Program input (corresponding yellow LED flashes)
to the Program input (corresponding yellow LED flashes)
Adjusting the sound cone characteristics:
The ultrasonic sensor enables two different shapes of the sound cone, a wide angle sound cone and a small angle sound cone.
1. Small angle sound cone
• switch off the power supply
•connect the Teach-In input wire to -U
• switch on the power supply
• the red LED flashes once with a pause before the next.
• yellow LED: permanently on: indicates the presence of an object or disturbing object within the sens-
ing range
• disconnect the Teach-In input wire from -U
2. Wide angle sound cone
Release date: 2016-04-13 11:21 Date of issue: 2016-04-13 130229_eng.xml
• switch off the power supply
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
B
and the changing is saved
B
pause
3
Ultrasonic sensor UB500-18GM75-E7-V15
•connect the Teach-In input wire with +U
• switch on the power supply
• the red LED double-flashes with a long pause before the next.
• yellow LED: permanently on: indicates an object or disturbing object within the sensing range
• disconnect the Teach-In input wire from +U
B
and the changing is saved
B
pause
Factory settings
See technical data.
Display
The sensor provides LEDs to indicate various conditions.
During Normal operation
Proper operation
Interference (e.g. compressed air)
Programming of output 1
Object detected No object detected Object uncertain (programming invalid)
Programming of output 2
Object detected No object detected Object uncertain (programming invalid)
Red LED Yellow LED 1 Yellow LED 2
Off
On
Off
Flashes
On
Off
Flashes
On
Switching state
output 1
remains in previous
state
Flashes
Off Off
Off Off Off
Switching state
output 2
remains in previous
state
Off Off Off
Flashes
Off Off
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the mounting flanges BF18, BF18-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be used.
Release date: 2016-04-13 11:21 Date of issue: 2016-04-13 130229_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.