Pepperl+Fuchs UB250-F77-E2-V31 Adjustment Manual

Page 1
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
1
Ultrasonic direct detection sensor UB250-F77-E2-V31
Technical data
General specifications
Sensing range 20 ... 250 mm Adjustment range 45 ... 250 mm Dead band 0 ... 20 mm Standard target plate 20 mm x 20 mm Transducer frequency approx. 400 kHz
Nominal ratings
Time delay before availability t
v
150 ms
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED yellow switching state and flashing: Teach-In
Electrical specifications
Rated operating voltage U
e
24 V DC
Operating voltage U
B
20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %
No-load supply current I
0
20 mA
Input
Input type 1 program input Level low level : 0 ... 0.7 V (Teach-In active)
high level : U
B
or open input (Teach-In inactive)
Input impedance 16 k Pulse length 3 s
Output
Output type 1 switch output PNP, NO Rated operating current I
e
200 mA , short-circuit/overload protected
Voltage drop U
d
2 V
Switch-on delay t
on
50 ms Repeat accuracy ± 1 mm Switching frequency f 10 Hz Range hysteresis H typ. 2.5 mm Off-state current I
r
0.01 mA Temperature influence + 0.17 %/K
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F) Shock resistance 30 g , 11 ms period Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type M8 x 1 connector , 4-pin Degree of protection IP67 Material
Housing Polycarbonate
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Installation position any position Mass 10 g Tightening torque, fastening screws max. 0.2 Nm
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
IEC 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
36 V
Model Number
UB250-F77-E2-V31
Ultrasonic direct detection sensor
Features
• Miniature design
• Program input
• Degree of protection IP67
• Switching status indicator, yellow LED
Diagrams
Characteristic response curve
Distance X [mm]
Distance Y [mm]
X
Y
0 50 100 150 200 250 300
50
40
30
20
10
0
-10
-20
-30
-40
-50
Page 2
Ultrasonic direct detection sensor UB250-F77-E2-V31
2
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Dimensions
Electrical Connection
Pinout
12
3.2
23
3.2
ø3.2
322
25
3 14
17
M8 x 1
189
31
+U
B
-U
B
1
4
2
3
Switching output
ET (Teaching input)
13
24
1 BN 2 WH 3 BU 4 BK
Wire colors in accordance with EN 60947-5-2
(brown) (white) (blue) (black)
Page 3
Ultrasonic direct detection sensor UB250-F77-E2-V31
3
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Description of Sensor Function
The ultrasonic sensor transmits ultrasonic packets in quick succession and responds to their reflection off the detected object. The sensor has a switch output. The switching point is progammable (Teach-In). Objects beyond the taught-in switching point are not detected (background suppression).
Teach-In of Switching Point SP
To teach in a switching point, proceed as follows:
1. Connect the sensor and turn on the operating voltage.
2. Place the object to be detected at the required distance.
3. Connect the teach-in input (ET) to -U
B
. This can be done usingthepushbutton or the controller.
The LED will start flashing after 3 seconds to indicate that the sensor is ready to start the teach-in process
(*)
.
4. Disconnect the teach-in input (ET) with -U
B
. The switching point SP has now been taught in
(*)
.
(*) If no object is detected within the sensing range of the sensor, the sensor will start flashing at a faster rate. The switching point remains
unchanged.
Switching characteristics and display LED
" = Object position
Safety Note
The use of this device in applications, where the safety of persons depends from the devices function, is not allowed!
Accessories
UB-PROG4-V31
Programming unit for ultrasonic sensors with Teach-in input at pin 2
OMH-ML7-01
Mounting aid for ML7 and ML8 series, Mounting bracket
V31-GM-2M-PVC
Female cordset, M8, 4-pin, PVC cable
V31-WM-2M-PVC
Female cordset, M8, 4-pin, PVC cable
unusable
area
Sensing range Output LED
Adjustment range
" -U
B
Off
" +U
B
On
" Undefined
Loading...