General specifications
Sensing range 60 ... 2000 mm Adjustment range 90 ... 2000 mm Dead band 0 ... 60 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 175 kHz Response delay approx. 150 ms
Indicators/operating means
LED green solid green: Power on
Model Number
UB2000-F42S-I-V15
Single head system
Features
• Analog output 4 mA ... 20 mA
• Extremely small unusable area
• TEACH-IN
• Interference suppression (adjus­table divergence of sound cone in close range)
• Temperature compensation
• Synchronization options
• Mode of operation adjustable
Diagrams
Characteristic response curve
Distance Y [m]
1
Flat surface 100 mm x 100 mm
0.5
0
-0.5
Round bar, Ø 25 mm
-1
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Y
X
wide sonic beam narrow sonic beam
Distance X [m]
LED yellow solid: object in evaluation range
LED red normal operation: "fault"
Electrical specifications
Operating voltage U
No-load supply current I
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation 30 Hz Multiplex operation 30/n Hz, n = number of sensors
Output
Output type 1 analog output 4 ... 20 mA Default setting evaluation limit A1: 90 mm , evaluation limit A2: 2000 mm ,
Resolution 0.7 mm Deviation of the characteristic curve ± 1 % of full-scale value Repeat accuracy ± 0.1 % of full-scale value Load impedance 0 ... 300 Ohm Temperature influence ± 1 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP54 Material
Housing ABS Transducer epoxy resin/hollow glass sphere mixture; foam
Mass 140 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
B
0
flashing: program function
program function: no object detected
10 ... 30 V DC , ripple 10 %
50 mA
0 level -U 1 level: +4 V...+U input impedance: > 12 KOhm
synchronization pulse: 100 µs, synchronization interpulse period: 2 ms
wide sound lobe
polyurethane, cover PBT
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
36 V
...+1 V
B
B
SS
Release date: 2016-02-26 11:31 Date of issue: 2016-02-26 133997_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ultrasonic sensor UB2000-F42S-I-V15
Dimensions
Membrane keys
LED window
Additional Information
Analogue output programmation
7.5
15
15.5
2
A
TEACH IN
1
MODE SET
A
10
34
52.5
34
M12x1
5
16
5.2
Rising ramp
80
65
65
80
22
Falling ramp
Zero line
A1 = 0
Unusable area
A1A1
A1 A2
Object distance
A2
A2
Electrical Connection
Standard symbol/Connections:
(version I)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
(BN)
1
(WH)
2
(GY)
5
(BK)
4
(BU)
3
2
+ U
B
Teaching input
Sync.
Analog output
- U
B
1
5
4
3
(brown) (white) (blue) (black) (gray)
Release date: 2016-02-26 11:31 Date of issue: 2016-02-26 133997_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...
+ 2 hidden pages