Ultrasonic sensor UB120-F12P-EP-V15
Technical data
General specifications
Sensing range 15 ... 150 mm
Adjustment range 15 ... 120 mm
Dead band 0 ... 15 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 850 kHz
Response delay approx. 10 ms
Indicators/operating means
LED green Operating display
LED yellow switch output
Model Number
UB120-F12P-EP-V15
Single head system
Features
• Switching point adjustment via
potentiometer
• Extremely narrow projection cone
• Synchronization options
• Very small unusable area
• Push-pull output
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
75
50
25
1
0
-25
-50
-75
0 25 50 75 100 125 150 175 200
Y
Curve 1: flat surface 10 mm x 10 mm
Curve 2: round bar, Ø 8 mm
2
Distance X [mm]
X
LED red solid: stop plate switch point adjuster
Electrical specifications
Operating voltage U
No-load supply current I
Input/Output
Synchronization 1 synchronous connection, bi-directional
Synchronization frequency
Common mode operation ≤ 45 Hz
Multiplex operation ≤ 45/n Hz, n = number of sensors
Output
Output type Push-pull output, short-circuit protected, reverse polarity
Rated operating current I
Voltage drop U
Repeat accuracy ≤ 1 %
Switching frequency f 50 Hz
Range hysteresis H 1 mm
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -15 ... 70 °C (5 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP54
Material
Housing Frame: nickel plated, die cast zinc,
Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 60 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
e
d
flashing: error
10 ... 30 V DC , ripple 10 %
≤ 60 mA
0-level: -U
1-level: +4 V...+U
input impedance: > 12 kΩ
synchronization pulse: ≥ 100 µs, synchronization interpulse
period: ≥ 2 ms
protected
200 mA , short-circuit/overload protected
≤ 3 V
Laterals: glass-fiber reinforced plastic PC
cover PBT
IEC 60947-5-2:2007 + A1:2012
...+1 V
B
SS
B
Release date: 2016-04-25 09:32 Date of issue: 2016-04-25 203368_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UB120-F12P-EP-V15
Dimensions
M4 / 4 deep
15
5.3
5.5
2
1
7.5
19.5
Additional Information
10
41.51.5
ø4.5
7
49
65
2
M12x1
24
Connector 90° adjustable position
11.5
2
3
4
5
32.5
1 Operating display green
2 Switch state yellow
3 Turnover switch Q / Q
4 Switching point adjuster
5 Acoustic axis transducer
Switching output function
1. normally open function Q
2. normally closed function Q
object distance
Electrical Connection
Standard symbol/Connections:
(version EP, pnp/npn)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
5 GY
(BN)
1
(WH)
2
(GY)
5
(BK)
4
(BU)
3
2
+ U
n.c.
Synchronous
Switch output
- U
1
5
B
B
4
3
(brown)
(white)
(blue)
(black)
(gray)
Release date: 2016-04-25 09:32 Date of issue: 2016-04-25 203368_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2

Ultrasonic sensor UB120-F12P-EP-V15
Accessories
OMH-K01
dove tail mounting clamp
OMH-K02
dove tail mounting clamp
OMH-K03
dove tail mounting clamp
OMH-01
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
OMH-06
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
OMH-MLV12-HWG
Mounting bracket for series MLV12 sensors
OMH-MLV12-HWK
Mounting bracket for series MLV12 sensors
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Synchronisation
To suppress mutual influence, the sensor is equipped with a synchronisation connection. If this is not activated, the sensor
works with an internally generated clock. Synchronisation of multiple sensors can be achieved in the following ways.
External synchronisation
The sensor can be synchronized by external application of a square wave voltage. A synchronisation impulse on the synchronisation input leads to the execution of one measurement cycle. The impulse width must be larger than 100 µs. The measure-
ment cycle starts with the falling flank. A low level > 1 sec or an open synchronisation input puts the sensor in normal mode. A
high level on the synchronisation input deactivates the sensor.
Two operational modes are possible
1. Multiple sensors are controlled using the same synchronisation signal. The sensors work in synch.
2. The synchronisation impulses are cyclically fed to only one sensor at a time. The sensors work in multiplex mode.
Autosynchronisation
The synchronisation connections of up to 10 sensors are connected together. These sensors then work in multiplex mode after
power is switched on. The activation delay is increased corresponding to the numer of synchronised sensors.
Note:
If the synchronisation option is not used, the sync. input should be connected to ground (0V), or the sensor connected using a
V1 connector cable (4-pin).
Setting the switch point
The ultrasonic sensor possesses a switch output, of which the switching point can be set simply and precisely using the builtin 12-position potentiometer. Using the switch Q/Q
direction of the switching output can be selected.
There are two different output functions which can be selected
1. one switching point, normally open
2. one switching point, normally closed
LED display
Opening function (Q\) Closing function (Q)
LED green: Power On
LED yellow: Switch state
Object outside switching area, or
no object
LED red Potentiometer for setting of switch point at "limit"
LED red flashing Ultrasonic error
which is also easy to find on the upper side of the sensor, the effective
Switch state
Object detected in switching area
Release date: 2016-04-25 09:32 Date of issue: 2016-04-25 203368_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3