Instruction Manual
1. Marking
6. Improper Use
Protection of the personnel and the plant is not ensured if the device is not
used according to its intended use.
Power Supply Unit
SK-IDM-Z1-160-BD-1D-J1-DC-S-N0,
SK-IDM-Z1-160-BD-1D-J1-DC-U-N0,
SK-IDM-Z1-160-BD-1D-J1-AC-S-N0,
SK-IDM-Z1-160-BD-1D-J1-AC-U-N0,
SK-IDM-Z1-260-D-2D-J1-DC-S-N0,
SK-IDM-Z1-260-D-2D-J1-AC-S-N0
SK-IDM-Z1-260-D-2D-J1-DC-U-N,
SK-IDM-Z1-260-D-2D-J1-AC-U-N
Equipment protection level Gb
ATEX certificate: IBExU 18 ATEX 1051
ATEX marking: 1 II 2G Ex eb q [ib IIC/IIB] IIC T4 Gb
IECEx certificate: IECEx IBE 18.0010
IECEx marking: Ex eb q [ib IIC/IIB] IIC T4 Gb
Equipment protection level Db
ATEX certificate0: IBExU 18 ATEX 1051
ATEX marking: 1 II 2D Ex tb [ib] IIIC T135°C Db
IECEx certificate: IECEx IBE 18.0010
IECEx marking: Ex tb [ib] IIIC T135°C Db
Pepperl+Fuchs Group
Lilienthalstraße 200, 68307 Mannheim, Germany
Internet: www.pepperl-fuchs.com
2. Validity
Specific processes and instructions in this instruction manual require
special provisions to guarantee the safety of the operating personnel.
3. Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation,
maintenance, and dismounting lies with the plant operator.
The personnel must be appropriately trained and qualified in order to carry
out mounting, installation, commissioning, operation, maintenance, and
dismounting of the device. The trained and qualified personnel must have
read and understood the instruction manual.
4. Reference to Further Documentation
Observe laws, standards, and directives applicable to the intended use
and the operating location. Observe Directive 1999/92/EC in relation to
hazardous areas.
Observe laws, standards, and directives applicable to the intended use
and the operating location.
Refer to the relevant EU-type examination certificate to see the
relationship between the connected circuit type, the maximum permitted
ambient temperature, the surface temperature, and the effective inner
reactances.
The corresponding datasheets, manuals, declarations of conformity, EUtype examination certificates, certificates, and control drawings if
applicable (see datasheet) are an integral part of this document. You can
find this information under www.pepperl-fuchs.com.
Due to constant revisions, documentation is subject to permanent change.
Please refer only to the most up-to-date version, which can be found under
www.pepperl-fuchs.com.
5. Intended Use
The device is only approved for appropriate and intended use. Ignoring
these instructions will void any warranty and absolve the manufacturer
from any liability.
The power supply unit supplies the following devices:
l
Handheld readers IDM-Z1-160-D-1D-J1-SU-N-N0,
IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D-J1-S1-N-N0
l
Bluetooth handheld readers IDM-Z1-161-M-1D-J1-BT-N-N0,
IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D-J1-BT-N-N0
l
Base station IDM-Z1-X61-B-1D-J1-BT-N0
The device is available with RS-232, RS-485, or with USB interface. The
device is available in 3 supply versions.
The device is an electrical apparatus for hazardous areas.
The device may be installed in Zones 1 and 21.
Take the intended use of the connected devices from the corresponding
documentation.
7. Mounting and Installation
Prior to using the product make yourself familiar with it. Read the
instruction manual carefully.
Only use accessories specified by the manufacturer.
Adjust the sealing element of the cable gland to the diameter of the cables
and connection lines used.
Ensure that all cable glands are in good condition and are securely
tightened.
Requirements for Cables and Connection Lines
Only cables and connection lines that meet the requirements of the
respective hazardous area certificate of the device may be connected to
the intrinsically safe connection.
Only use cables and connection lines with a temperature range
appropriate to the application.
Observe the permissible cable type and cable length given in the
respective hazardous area certificate.
Regarding the verification of intrinsic safety, observe the maximum
permissible external capacitance of this device and the other devices in
the circuit.
Install the cables and connection lines in such a way that they are
protected from ultraviolet radiation.
Install cables and cable glands in a way that they are not exposed to
mechanical hazards.
Protect cables and cable glands from tensile load and torsional stress or
use certified cable glands.
The dielectric strength of the insulation must be at least 500 V according to
IEC/EN 60079-14.
Observe the permissible core cross section of the conductor.
When installing the conductors the insulation must reach up to the
terminal.
When using stranded conductors, crimp wire end ferrules on the
conductor ends.
Do not use aluminum wire for connection of the device.
Protect plastic cable glands against mechanical hazard.
Never pull the cable. A wire could become loose from the terminal and
protection against electric shock can no longer be ensured. Always pull
the terminal.
Observe the minimum bending radius of the conductors.
Unused cables and connection lines must be connected to earth or be
adequately insulated by means of terminals suitable for the type of
protection.
Observe the grounding requirements for type of protection Ex i according
to IEC/EN 60079‑14.
8. Operation, Maintenance, Repair
Prior to using the product make yourself familiar with it. Read the
instruction manual carefully.
Observe the warning markings.
The device must not be repaired, changed, or manipulated. In case of
failure, always replace the device with an original device.
Do not use a damaged or polluted device.
Do not connect or disconnect the electrical connection when energized.
If cleaning is necessary while the device is located in a hazardous area, in
order to avoid electrostatic charging only use a clean damp cloth.
Observe IEC/EN 60079-17 for maintenance and inspection.
Only operate the device with a closed Ex e terminal compartment.
Remove the dust before opening the terminal compartment.
9. Delivery, Transport, Disposal
Check the packaging and contents for damage.
Check if you have received every item and if the items received are the
ones you ordered.
Always store and transport the device in the original packaging.
Store the device in a clean and dry environment. The permitted ambient
conditions must be considered, see datasheet.
The device, built-in components, packaging, and any batteries contained
within must be disposed in compliance with the applicable laws and
guidelines of the respective country.
DOCT-6131A / 2019-12 1 / 1