Inductive slot sensor |
SJ5-N |
|
|
|
|
0102
Model Number
SJ5-N
Features
•5 mm slot width
•Usable up to SIL 2 acc. to IEC 61508
<![if ! IE]><![endif]>Release date: 2017-02-16 15:20 Date of issue: 2018-02-16 106607_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Technical Data
General specifications |
|
|
Normally closed (NC) |
|||||||||||||||||
Switching function |
|
|
||||||||||||||||||
Output type |
|
|
NAMUR |
|
|
|
|
|
|
|
|
|
||||||||
Slot width |
|
|
5 mm |
|
|
|
|
|
|
|
|
|
||||||||
Depth of immersion (lateral) |
|
|
5 ... 7 mm , typ. 6 mm |
|||||||||||||||||
Output type |
|
|
2-wire |
|
|
|
|
|
|
|
|
|
||||||||
Nominal ratings |
Uo |
8.2 V (Ri approx. 1 kΩ) |
||||||||||||||||||
Nominal voltage |
||||||||||||||||||||
Operating voltage |
UB |
5 ... 25 V |
|
|
|
|
|
|
|
|
|
|||||||||
Switching frequency |
f |
0 ... 2000 Hz |
||||||||||||||||||
Hysteresis |
H |
0.05 ... 0.65 mm |
||||||||||||||||||
Design data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current consumption |
|
|
≥ 3 mA |
|
|
|
|
|
|
|
|
|
||||||||
Measuring plate not detected |
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Measuring plate detected |
|
|
≤ 1 mA |
|
|
|
|
|
|
|
|
|
||||||||
Functional safety related parameters |
9060 a |
|
|
|
|
|
|
|
|
|
||||||||||
MTTFd |
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Mission Time (TM) |
|
|
20 a |
|
|
|
|
|
|
|
|
|
||||||||
Diagnostic Coverage (DC) |
|
|
0 % |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ambient conditions |
|
|
-25 ... 100 °C (-13 ... 212 °F) |
|||||||||||||||||
Ambient temperature |
|
|
||||||||||||||||||
Mechanical specifications |
|
|
flexible leads LiY , 500 mm |
|||||||||||||||||
Connection type |
|
|
||||||||||||||||||
Core cross-section |
|
|
0.14 mm2 |
|
|
|
|
|
|
|
|
|
||||||||
Housing material |
|
|
PBT |
|
|
|
|
|
|
|
|
|
||||||||
Degree of protection |
|
|
IP67 |
|
|
|
|
|
|
|
|
|
||||||||
General information |
|
|
see instruction manuals |
|||||||||||||||||
Use in the hazardous area |
|
|
||||||||||||||||||
Category |
|
|
1G; 2G; 1D |
|
|
|
|
|
|
|
|
|
||||||||
Compliance with standards and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
directives |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard conformity |
|
|
EN 60947-5-6:2000 |
|||||||||||||||||
NAMUR |
|
|
||||||||||||||||||
Standards |
|
|
IEC 60947-5-6:1999 |
|||||||||||||||||
|
|
EN 60947-5-2:2007 |
||||||||||||||||||
Approvals and certificates |
|
|
IEC 60947-5-2:2007 |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FM approval |
|
|
116-0165 |
|
|
|
|
|
|
|
|
|
|
|
||||||
Control drawing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
UL approval |
|
|
cULus Listed, General Purpose |
|||||||||||||||||
CSA approval |
|
|
cCSAus Listed, General Purpose |
|||||||||||||||||
CCC approval |
|
|
CCC approval / marking not required for products rated ≤36 V |
|||||||||||||||||
Dimensions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
5 |
|
|
|
|
|
|
|
|||||
|
<![if ! IE]> <![endif]>10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>15 |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
|
<![if ! IE]> <![endif]>2 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6,9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
15 |
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
<![if ! IE]> <![endif]>10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>3 |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ø 1,7 |
|
|
|
|
|
|
|
|
|
|
|
|
Electrical Connection
BN
L+
BU
L-
1
|
|
|
|
|
|
|
|
|
Inductive slot sensor |
|
SJ5-N |
||
|
|
|
|
|
|
|
|
Equipment protection level Ga |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1G Ex ia IIC T6…T1 Ga |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-...-N... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 250 H ; a cable length of 10 m is considered. |
|
||
|
Highest permissible ambient temperature |
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the |
|
|||
|
|
|
|
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
|
|
|
|
|
|
Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already |
|
|
|
|
|
|
been applied to the temperature table for category 1. |
|
|
|
|
|
|
|
|
|
|
Equipment protection level Gb |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1G Ex ia IIC T6…T1 Ga |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-...-N... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 250 H ; a cable length of 10 m is considered. |
|
||
|
Maximum permissible ambient temperature Tamb |
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the |
|
|||
|
|
|
|
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
|
|
|
|
|
|
|
|
|
|
Equipment protection level Da |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1D Ex ia IIIC T135°C Da |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-...-N... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 250 H ; a cable length of 10 m is considered. |
|
<![endif]>Release date: 2017-02-16 15:20 Date of issue: 2018-02-16 106607_eng.xml
2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.