Inductive slot sensor |
SJ5-K-N |
|
|
|
|
0102
Model Number
SJ5-K-N
Features
•5 mm slot width
<![if ! IE]><![endif]>106605_eng.xml
Technical Data
General specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switching function |
|
Normally closed (NC) |
||||||||||||||||||||||
Output type |
|
NAMUR |
|
|
|
|
|
|
||||||||||||||||
Slot width |
|
5 mm |
|
|
|
|
|
|
||||||||||||||||
Depth of immersion (lateral) |
|
8 ... 10 mm , typ. 9 mm |
||||||||||||||||||||||
Output type |
|
2-wire |
|
|
|
|
|
|
||||||||||||||||
Nominal ratings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal voltage |
Uo |
8.2 V (Ri approx. 1 kΩ) |
||||||||||||||||||||||
Operating voltage |
UB |
5 ... 25 V |
|
|
|
|
|
|
||||||||||||||||
Switching frequency |
f |
0 ... 2000 Hz |
|
|
|
|
|
|
||||||||||||||||
Hysteresis |
H |
0.05 ... 0.3 mm |
|
|
|
|
|
|
||||||||||||||||
Design data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current consumption |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measuring plate not detected |
|
≥ 3 mA |
|
|
|
|
|
|
||||||||||||||||
Measuring plate detected |
|
≤ 1 mA |
|
|
|
|
|
|
||||||||||||||||
Functional safety related parameters |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MTTFd |
|
4560 a |
|
|
|
|
|
|
||||||||||||||||
Mission Time (TM) |
|
20 a |
|
|
|
|
|
|
||||||||||||||||
Diagnostic Coverage (DC) |
|
0 % |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ambient temperature |
|
-25 ... 100 °C (-13 ... 212 °F) |
||||||||||||||||||||||
Mechanical specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection type |
|
cable PVC , 2 m |
|
|
|
|
|
|
||||||||||||||||
Core cross-section |
|
0.75 mm2 |
|
|
|
|
|
|
||||||||||||||||
Housing material |
|
PBT |
|
|
|
|
|
|
||||||||||||||||
Degree of protection |
|
IP67 |
|
|
|
|
|
|
||||||||||||||||
Cable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bending radius |
|
> 10 x cable diameter |
||||||||||||||||||||||
General information |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Use in the hazardous area |
|
see instruction manuals |
||||||||||||||||||||||
Category |
|
1G; 2G; 1D |
|
|
|
|
|
|
||||||||||||||||
Compliance with standards and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
directives |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard conformity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NAMUR |
|
EN 60947-5-6:2000 |
|
|
|
|||||||||||||||||||
|
|
IEC 60947-5-6:1999 |
|
|
|
|||||||||||||||||||
Standards |
|
EN 60947-5-2:2007 |
|
|
|
|||||||||||||||||||
|
|
IEC 60947-5-2:2007 |
|
|
|
|||||||||||||||||||
Approvals and certificates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FM approval |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control drawing |
|
116-0165 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
UL approval |
|
cULus Listed, General Purpose |
|
|||||||||||||||||||||
CSA approval |
|
cCSAus Listed, General Purpose |
|
|||||||||||||||||||||
CCC approval |
|
CCC approval / marking not required for products rated ≤36 V |
|
|||||||||||||||||||||
Dimensions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
26 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>19 |
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>31 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>6 |
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
13 |
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
29 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>15 |
<![if ! IE]> <![endif]>24 |
|
<![if ! IE]> <![endif]>32 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ø 3,5 |
|
9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![endif]>Release date: 2017-02-16 15:20 Date of issue: 2018-02-16
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical Connection
BN
L+
BU
L-
1
|
|
|
|
|
|
|
|
|
Inductive slot sensor |
|
SJ5-K-N |
||
|
|
|
|
|
|
|
|
Equipment protection level Ga |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1G Ex ia IIC T6…T1 Ga |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-K... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 550 H ; a cable length of 10 m is considered. |
|
||
|
Highest permissible ambient temperature |
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the |
|
|||
|
|
|
|
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
|
|
|
|
|
|
Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already |
|
|
|
|
|
|
been applied to the temperature table for category 1. |
|
|
|
|
|
|
|
|
|
|
Equipment protection level Gb |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1G Ex ia IIC T6…T1 Ga |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-K... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 550 H ; a cable length of 10 m is considered. |
|
||
|
Maximum permissible ambient temperature Tamb |
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the |
|
|||
|
|
|
|
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
|
|
|
|
|
|
|
|
|
|
Equipment protection level Da |
|
|
|
|
|
|
CE marking |
|
|
0102 |
|
|
|
|
|
|
|
|
|
|
ATEX marking |
|
¬II 1D Ex ia IIIC T135°C Da |
|||
|
|
|
|
The Ex-related marking can also be printed on the enclosed label. |
||
|
Standards |
|
EN 60079-0:2012+A11:2013, EN 60079-11:2012 |
|
||
|
|
|
|
Ignition protection "Intrinsic safety" |
|
|
|
|
|
|
Use is restricted to the following stated conditions |
|
|
|
Appropriate type |
|
SJ5-K... |
|
||
|
Effective internal inductivity |
Ci |
≤ 50 nF ; a cable length of 10 m is considered. |
|
||
|
Effective internal inductance |
Li |
≤ 550 H ; a cable length of 10 m is considered. |
|
<![endif]>Release date: 2017-02-16 15:20 Date of issue: 2018-02-16 106605_eng.xml
2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.