Pepperl Fuchs SJ30-N Data Sheet

Pepperl Fuchs SJ30-N Data Sheet

 

 

 

 

 

 

Inductive slot sensor

SJ30-N

 

 

 

 

0102

Model Number

SJ30-N

Features

30 mm slot width

<![if ! IE]>

<![endif]>Release date: 2018-04-18 08:24 Date of issue: 2018-04-18 106616_eng.xml

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Technical Data

General specifications

 

Normally closed (NC)

Switching function

 

Output type

 

NAMUR

Slot width

 

30 mm

Depth of immersion (lateral)

 

27 ... 30 mm

Output type

 

2-wire

Nominal ratings

Uo

8.2 V (Ri approx. 1 kΩ)

Nominal voltage

Operating voltage

UB

5 ... 25 V

Switching frequency

f

0 ... 150 Hz

Hysteresis

H

0.1 ... 0.3 mm

Design data

 

 

Current consumption

 

≥ 3 mA

Measuring plate not detected

 

Measuring plate detected

 

≤ 1 mA

Functional safety related parameters

5270 a

MTTFd

 

Mission Time (TM)

 

20 a

Diagnostic Coverage (DC)

 

0 %

Ambient conditions

 

-25 ... 70 °C (-13 ... 158 °F)

Ambient temperature

 

Mechanical specifications

 

cable PVC , 2 m

Connection type

 

Core cross-section

 

0.75 mm2

Housing material

 

ABS

Degree of protection

 

IP67

Cable

 

> 10 x cable diameter

Bending radius

 

Mass

 

450 g

General information

 

see instruction manuals

Use in the hazardous area

 

Category

 

1G; 2G; 1D

Compliance with standards and

 

 

directives

 

 

Standard conformity

 

EN 60947-5-6:2000

NAMUR

 

Standards

 

IEC 60947-5-6:1999

 

EN 60947-5-2:2007

 

 

EN 60947-5-2/A1:2012

 

 

IEC 60947-5-2:2007

Approvals and certificates

 

IEC 60947-5-2 AMD 1:2012

 

 

FM approval

 

116-0165

Control drawing

 

UL approval

 

cULus Listed, General Purpose

CSA approval

 

cCSAus Listed, General Purpose

CCC approval

 

CCC approval / marking not required for products rated ≤36 V

Dimensions

 

76

23

30

<![if ! IE]>

<![endif]>110

<![if ! IE]>

<![endif]>80

<![if ! IE]>

<![endif]>M24x 1.5

<![if ! IE]>

<![endif]>27ø

 

 

Pg13.5

 

84

ø 6.5

<![if ! IE]>

<![endif]>51

<![if ! IE]>

<![endif]>23

Electrical Connection

BN

L+

BU

L-

1

 

 

 

 

 

 

 

 

Inductive slot sensor

 

SJ30-N

 

 

 

 

 

 

 

 

Equipment protection level Ga

 

 

 

 

 

CE marking

 

 

0102

 

 

 

 

 

 

 

 

 

ATEX marking

 

¬II 1G Ex ia IIC T6T1 Ga

 

 

 

 

The Ex-related marking can also be printed on the enclosed label.

 

Standards

 

EN 60079-0:2012+A11:2013, EN 60079-11:2012

 

 

 

 

 

Ignition protection "Intrinsic safety"

 

 

 

 

 

Use is restricted to the following stated conditions

 

 

Appropriate type

 

SJ30-N...

 

 

Effective internal inductivity

Ci

150 nF ; a cable length of 10 m is considered.

 

 

Effective internal inductance

Li

1250 H ; a cable length of 10 m is considered.

 

 

Highest permissible ambient temperature

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

 

 

 

temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.

 

 

 

 

 

Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already

 

 

 

 

 

been applied to the temperature table for category 1.

 

 

 

 

 

 

 

 

Equipment protection level Gb

 

 

 

 

 

CE marking

 

 

0102

 

 

 

 

 

 

 

 

 

ATEX marking

 

¬II 1G Ex ia IIC T6T1 Ga

 

 

 

 

The Ex-related marking can also be printed on the enclosed label.

 

Standards

 

EN 60079-0:2012+A11:2013, EN 60079-11:2012

 

 

 

 

 

Ignition protection "Intrinsic safety"

 

 

 

 

 

Use is restricted to the following stated conditions

 

 

Appropriate type

 

SJ30-N...

 

 

Effective internal inductivity

Ci

150 nF ; a cable length of 10 m is considered.

 

 

Effective internal inductance

Li

1250 H ; a cable length of 10 m is considered.

 

 

Maximum permissible ambient temperature Tamb

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

 

 

 

temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.

 

 

 

 

 

 

 

 

Equipment protection level Da

 

 

 

 

 

CE marking

 

 

0102

 

 

 

 

 

 

 

 

 

ATEX marking

 

¬II 1D Ex ia IIIC T135°C Da

 

 

 

 

The Ex-related marking can also be printed on the enclosed label.

 

Standards

 

EN 60079-0:2012+A11:2013, EN 60079-11:2012

 

 

 

 

 

Ignition protection "Intrinsic safety"

 

 

 

 

 

Use is restricted to the following stated conditions

 

 

Appropriate type

 

SJ30-N...

 

 

Effective internal inductivity

Ci

150 nF ; a cable length of 10 m is considered.

 

 

Effective internal inductance

Li

1250 H ; a cable length of 10 m is considered.

 

<![if ! IE]>

<![endif]>Release date: 2018-04-18 08:24 Date of issue: 2018-04-18 106616_eng.xml