With regard to the supply of products, the current issue of the following document is applicable: The
General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central
Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.)
in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"
4.2UL Control Drawing ..................................................................................... 55
2020-04
3
VisuNet GXP
Introduction
1Introduction
1.1Content of this Document
This document contains information that you need in order to use your product throughout the
applicable stages of the product life cycle. These can include the following:
•Product identification
•Delivery, transport, and storage
•Mounting and installation
•Commissioning and operation
•Maintenance and repair
•Troubleshooting
•Dismounting
•Disposal
Note
This document does not substitute the instruction manual.
Note
For full information on the product, refer to the instruction manual and further documentation on
the Internet at www.pepperl-fuchs.com.
The documentation consists of the following parts:
•Present document
•Instruction manual
•Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
•EU-type examination certificate
•EU declaration of conformity
•Attestation of conformity
•Certificates
•Control drawings
•Additional documents
1.2Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismounting lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, commissioning, operation, maintenance, and dismounting of the product. The personnel must have
read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
4
2020-04
VisuNet GXP
Introduction
1.3Symbols Used
This document contains symbols for the identification of warning messages and of informative
messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory
that you observe these warning messages for your personal safety and in order to avoid property damage.
Depending on the risk level, the warning messages are displayed in descending order as follows:
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in
their complete failure.
Informative Symbols
Note
This symbol brings important information to your attention.
Action
This symbol indicates a paragraph with instructions. You are prompted to perform an action or
a sequence of actions.
2020-04
5
VisuNet GXP
Product Description
2Product Description
2.1Overview
The Pepperl+Fuchs VisuNet Remote Monitors GXP RM-GXP1100-19S*/RM-GXP1200-19S*
and PC-GXP-1100-19S*/PC-GXP-1200-19S* are ATEX/IECEx certified, UL listed devices
intended for use in potentially explosive atmospheres, such as Zones 1/21, 2/22 and Class I
Div. 2, Class II Div. 2, and Class III.
The VisuNet GXP serves as a thin client- or PC-based operator workstation that uses standard
Ethernet technology to transmit process information from a process control or manufacturing
execution system into hazardous areas.
The assembly consists of several core devices that can be exchanged by the customer:
•The display units DPU1100-* and DPU1200-* are display panels with optional 10-finger
multi-touch sensors. The displays and touch-sensors are optically bonded with the hardened front glass.
•The thin client units TCU1100-* and TCU1200-* are computing units running the latest
Pepperl+Fuchs RM Shell 5.x or RM Shell 4.x firmware. They allow connectivity to various
host systems in the safe area using standard Ethernet technology. The computing units
PCU1100-* and PCU1200-* run an open Microsoft® Windows® operating system, allowing installation of any software, such as SCADA packages.
•The power supply units PSU1100-* and PSU1200-* provide the above-listed devices with
24 V DC power. They are available as DC and AC versions.
As the standard mounting option, a bezel is available that allows the panel to be mounted into a
system housing or cabinet that needs to be ordered separately. The panel can also be flushmounted into a cabinet from behind.
2020-04
6
VisuNet GXP
1
2
3
4
Product Description
VisuNet GXP Panel Components
Figure 2.1VisuNet GXP panel components
1Bezel for housing and panel mounting
2Computing unit (TCU or PCU): processor, SSD and memory, Ex circuits,
interface modules
3Power supply unit: DC or AC option, backpacked (panel-mount) or stand-
alone (in system enclosure)
4Display unit: display, touch screen, hardened front glass
2020-04
7
VisuNet GXP
Product Description
VisuNet GXP Pedestal Mounted with Keyboard/Mouse
Figure 2.2VisuNet GXP system mounted in AG1 Housing with Pedestal5 -1458-* and EXTA2
keyboard/mouse (ordered separately)
Note
For a description of the product model nomenclature, see the VisuNet GXP PC or VisuNet GXP
RM product datasheets at www.pepperl-fuchs.com.
For more mounting options and information, see the datasheet "Mounting Options
'StandardLine' and 'BasicLine'".
2020-04
8
VisuNet GXP
Product Description
2.2Technical Specifications
Technical Data RM-GXP*
Hardware
ProcessorIntel® Atom™ Bay Trail E3827 1.75 GHz
RAM2048 MB DDR3L
Mass storage32 GByte industrial grade MLC SSD
Software
Operating systemVisuNet RM Shell 5.x (based on Microsoft®
Interface type1 x Ethernet 100/1000BASE-TX (Ex e) or
1 x fiber optic 1000BASE-SX (Multimode) or
1 x fiber optic 1000BASE-LX (Singlemode)
1 x USB 2.0 (Ex e)
2 x USB 1.1 (Ex i; intended for Pepperl+Fuchs
keyboard and mouse)
1 x DC or AC power in (via power supply unit)
Optional:
1 x barcode reader interface Pepperl+Fuchs
Pscan-D/B (Ex i)
"interface 3": 1 x barcode reader interface for
wired 1-D scanners IDM-160-D*, IDM-Z1160-D-* and base station IDMx61-B-* and
IDM-Z1-x61-B-*
"interface 4": 1 x barcode reader interface for
wired 2-D Scanner IDM-Z1-260-D-* (Ex i)
"interface 5": 1 x RS-232 interface with Power
Supply for miscellaneous devices and peripherals (Ex i)
1 x RS-232 (Ex e)
1 x RS-485 (Ex e)
1 x Ethernet 100/1000Base-TX (Ex e)
Bluetooth v4.0, communication distance up to
30 m in open terrain, transmission power +8
dBm, transmission frequency 2.402 ... 2.48
GHz
panel with AC: 524 mm x 453 mm x 137 mm
panel with AG1 housing: 582 mm x 490 mm x
224 mm
•Thin Client Units TCU1100-J1-* and TCU1200-J2-*
•Computing Units PCU1100-J1-* and PCU1200-J2-*
Marking
ATEX
RM-GXP1100-J1-*
RM-GXP1200-J2-*
IECEx
RM-GXP1100-J1-*Ex eb q ib [ib] IIC T4 IP66 Gb
RM-GXP1200-J2-*Ex ec [ib] q IIC T4 IP66 Gc
II 2G Ex eb q ib [ib] IIC T4 IP66 Gb
II 2D Ex tb [ib] IIIC T85°C IP66 Db
II 3G Ex ec [ib] q IIC T4 IP66 Gc
II 3D Ex tc [ib] IIIC T85 °C IP66 Dc
Ex tb [ib] IIIC T85°C IP66 Db
Ex tc [ib] IIIC T85 °C IP66 Dc
UL Marking
2020-04
11
VisuNet GXP
582
490
1702
228
475
1100
Product Description
2.3Dimensions
Dimensions with AG1 Housing and Pedestal
Figure 2.3Dimensions with StandardLine Pedestal5-1458-Fix and EXTA2 keyboard/mouse—sample
configuration
Note
Keyboard/mouse and pedestal are ordered separately.
12
2020-04
VisuNet GXP
524
137
453
499
480
167
419
400
270
Ø 6.5
± 0.5 (14 x)
Product Description
Panel Dimensions with Bezel
Panel Cut-Out Dimensions
Cut-out dimensions: 480 x 400 mm. For more information, see chapter 3.5.
2020-04
13
VisuNet GXP
490
582
583
62
532
285
686
413
Product Description
Wall Mount Dimensions
Figure 2.4Wall mount dimensions with additional wall brackets (#198768)
2.4Disposal
Follow all local and any other requirements for disposing of electronic equipment. When disposing of any system component, mark VOID across all certification labels.
2020-04
14
VisuNet GXP
Mechanical Installation
3Mechanical Installation
3.1General Installation Requirements
Observe the following requirements when installing the system components.
•The equipment must be installed by competent personnel in accordance with the instruc-
tions. National laws and regulations must be observed.
•The building installation must provide a 20 A overcurrent protection.
•The installer must make a readily accessible disconnect device available.
•The safety of any system incorporating the power supply unit is the responsibility of the
assembler of the system.
3.2Installation Tools
•4-mm and 5-mm torque Allen keys
•Open-ended wrench for cable glands
•Screws for floor or wall mounting. Choose the appropriate screws based on the mounting
conditions.
•Small cable ties
•Side cutters
•Strong adhesive tape, such as duct tape or packing tape
•At least 1 piece of thin, 2.5-m-long wire for pulling cables through the pedestal
Warning!
Risk of injury
Lifting the device on your own may lead to injury.
Do not attempt to lift the device on your own. Use a crane or have another person help you.
2020-04
15
VisuNet GXP
Mechanical Installation
3.3System Installation
3.3.1Preparation for System Installation
Warning!
Proper installation on the floor
It is the installer's responsibility to select a suitable location with sufficient strength to hold the
equipment. It is the installer's responsibility to select the proper screws based on the installation conditions.
Warning!
Distance between housing and wall
Provide at least 350 mm of space between the housing/pedestal assembly and the left wall.
This is required in order to properly open the housing and connect the GXP components.
16
Figure 3.1Distance required between housing/pedestal assembly and wall
2020-04
VisuNet GXP
400
180180
300
250
140
130
130
20
40
Ø 100
Ø 10
071
031
130
170
90
45°
1
0
5°
5°
184
Mechanical Installation
StandardLine Pedestal Floor-Mount Hole Pattern
BasicLine Pedestal Floor-Mount Hole Pattern
3.3.2Preparing the GXP Panel/Housing
The VisuNet GXP comes pre-assembled and consists of the core components display unit,
power supply unit, and thin client unit / power supply unit. If the AG1 housing option is chosen,
the panel is pre-mounted in the housing.
Required Components
•1 x pre-assembled VisuNet RM-GXP or PC-GXP panel (option: panel-mounted into AG1
housing)
2020-04
•2 x protective tubes
•Screws for housing
•EXTA2 keyboard and PEDESTAL5-xxxx-* (ordered separately)
Warning!
Risk of injury
Handling the devices with bare hands may cut fingers, hands, or wrists.
Wear gloves at all times during the installation process.
17
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.