VisuNet GXP
RM-GXP1100-22F RM-GXP1200-22F PC-GXP1100-22F PC-GXP1200-22F
Manual
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"
Worldwide
Pepperl+Fuchs Group
Lilienthalstr. 200
68307 Mannheim
Germany
Phone: +49 621 776 - 0
E-mail: info@de.pepperl-fuchs.com
North American Headquarters
Pepperl+Fuchs Inc.
1600 Enterprise Parkway
Twinsburg, Ohio 44087
USA
Phone: +1 330 425-3555
E-mail: sales@us.pepperl-fuchs.com
Asia Headquarters
Pepperl+Fuchs Pte. Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Phone: +65 6779-9091
E-mail: sales@sg.pepperl-fuchs.com https://www.pepperl-fuchs.com
VisuNet GXP
Contents
1 |
Introduction................................................................................................................ |
4 |
||
|
1.1 |
Content of this Document............................................................................. |
4 |
|
|
1.2 |
Target Group, Personnel ............................................................................... |
4 |
|
|
1.3 |
Symbols Used ................................................................................................ |
5 |
|
2 |
Product Description .................................................................................................. |
6 |
||
|
2.1 |
Overview......................................................................................................... |
6 |
|
|
2.2 |
Technical Specifications ............................................................................... |
9 |
|
|
2.3 |
Dimensions................................................................................................... |
13 |
|
3 |
Mechanical Installation ........................................................................................... |
16 |
||
|
3.1 |
Unpacking .................................................................................................... |
16 |
|
|
3.2 |
Electrical Installation................................................................................... |
18 |
|
|
3.3 |
System Installation ...................................................................................... |
18 |
|
|
3.3.1 |
|
General Installation Information ....................................................... |
18 |
|
3.3.2 |
|
Preparing for Pedestal Installation.................................................... |
19 |
|
3.3.3 |
|
Mounting the Housing onto the Pedestal ......................................... |
22 |
|
3.3.4 |
|
Installing Cables in the Pedestal ...................................................... |
26 |
|
3.3.5 |
|
Grounding the Housing to the Pedestal ........................................... |
29 |
|
3.3.6 |
|
Wall Mount Installation ..................................................................... |
31 |
|
3.3.7 |
|
Mounting the Keyboard.................................................................... |
33 |
|
3.3.8 |
|
Mounting the IDM-* Barcode Reader Holder Bracket ...................... |
35 |
|
3.3.9 |
|
Cable Installation for IDM-* Readers and Base Stations .................. |
39 |
|
3.3.10 |
Cable Installation for PSCAN-D-* Handheld Readers ...................... |
43 |
|
|
3.3.11 |
Closing the Housing......................................................................... |
46 |
|
|
3.3.12 |
Dismounting the Display Unit ........................................................... |
48 |
|
|
3.3.13 |
Panel Mount Installation................................................................... |
51 |
|
4 |
Appendix |
.................................................................................................................. |
57 |
|
|
4.1 |
Accessories.................................................................................................. |
57 |
<![endif]>2020-04
3
VisuNet GXP
Introduction
1Introduction
1.1Content of this Document
This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following:
•Product identification
•Delivery, transport, and storage
•Mounting and installation
•Commissioning and operation
•Maintenance and repair
•Troubleshooting
•Dismounting
•Disposal
Note
This document does not substitute the instruction manual.
Note
For full information on the product, refer to the instruction manual and further documentation on the Internet at www.pepperl-fuchs.com.
The documentation consists of the following parts:
•Present document
•Instruction manual
•Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
•EU-type examination certificate
•EU declaration of conformity
•Attestation of conformity
•Certificates
•Control drawings
•Additional documents
1.2Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismounting lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, commissioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
<![if ! IE]><![endif]>2020-04
4
VisuNet GXP
Introduction
1.3Symbols Used
This document contains symbols for the identification of warning messages and of informative messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid property damage.
Depending on the risk level, the warning messages are displayed in descending order as follows:
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure.
Informative Symbols
Note
This symbol brings important information to your attention.
Action
This symbol indicates a paragraph with instructions.You are prompted to perform an action or a sequence of actions.
<![if ! IE]><![endif]>2020-04
5
VisuNet GXP
Product Description
2Product Description
2.1Overview
Pepperl+Fuchs VisuNet GXP workstations are ATEX/IECEx certified, UL Listed PCs or thin-cli- ent based remote monitors intended for use in potentially explosive atmospheres such as Zones 1/21 and 2/22, Class I/II, Division 2, and Class III. Two display sizes are available—19 inch and 21.5 inch. This manual covers the 21.5 inch models. For information on the 19 inch models, see the product pages at www.pepperl-fuchs.com.
The modular VisuNet GXP consists of three core field-replaceable devices:
•DPU1100-* and DPU1200-* display units with optional 10-finger multi-touch sensors. The displays and touch tensors are optically bonded with the hardened front glass.
•Computing units:
•TCU1100-* and TCU1200-* thin client units that run the latest Pepperl+Fuchs RM Shell firmware. Using standard Ethernet technology, they allow connection to host systems in the non-Ex area.
•PCU1100-* and PCU1200-* PC units run an open Microsoft® Windows® operating system that allows installation of any software, including SCADA packages.
•PSU1100-* and PSU1200-* power supply units provide the above devices with 24 V DC power. They are available as DC or wide-range AC versions.
VisuNet GXP components come preassembled in a panel. As a standard mounting option, a bezel is available that allows the panel to be mounted into a system housing or cabinet (mounting kit required). The panel can also be flush mounted into a cabinet from behind with additional mounting brackets.
<![if ! IE]><![endif]>2020-04
6
VisuNet GXP
Product Description
VisuNet GXP Panel Components
1 |
2 |
|
3
4
Figure 2.1 VisuNet GXP panel components
1 |
Bezel for housing and panel mounting |
|
|
2 |
Computing unit (TCU or PCU): processor, SSD and memory, Ex circuits, |
|
interface modules |
|
|
3 |
Power supply unit: DC or AC option, backpacked (panel-mount) or stand- |
|
alone (in system enclosure) |
|
|
4 |
Display unit: display, touch screen, hardened front glass |
|
|
The VisuNet GXP system can also be ordered pre-mounted in an AG-XX00 housing, ready for pedestal or wall mounting.
<![if ! IE]><![endif]>2020-04
7
VisuNet GXP
Product Description
VisuNet GXP Pedestal Mounted with Keyboard/Mouse
Figure 2.2 VisuNet GXP workstation mounted in an AG-XX00 housing on a PEDESTAL-XX00-* pedestal with optional EXTA2-* keyboard/mouse (ordered separately)
Note
For a description of the product model nomenclature, see the VisuNet GXP PC or VisuNet GXP RM product datasheets at www.pepperl-fuchs.com.
For more mounting options and information, see the VisuNet Mounting Options datasheet.
<![if ! IE]><![endif]>2020-04
8
VisuNet GXP
Product Description
2.2 |
Technical Specifications |
|
|
|
Technical Data RM-GXP* |
|
|
|
|
|
|
|
Hardware |
|
|
|
|
|
|
|
Processor |
Intel® Atom™ Bay Trail E3827 1.75 GHz |
|
|
|
|
|
|
RAM |
2048 MB DDR3L |
|
|
|
|
|
|
Mass storage |
32 GByte industrial grade MLC SSD |
|
|
|
|
|
|
|
|
|
|
Software |
|
|
|
|
|
|
|
Operating system |
VisuNet RM Shell 5.x (based on Microsoft® |
|
|
|
Windows® 10 IoT LTSB) |
|
|
|
|
|
|
Technical Data PC-GXP* |
|
|
|
|
|
|
|
Hardware |
|
|
|
|
|
|
|
Processor |
Intel® Atom™ Bay Trail E3845 1.91 GHz |
|
|
|
|
|
|
RAM |
4096 MB DDR3L |
|
|
|
|
|
|
Mass storage |
128 GByte industrial grade MLC SSD |
|
|
|
|
|
|
|
|
|
|
Software |
|
|
|
|
|
|
|
Operating system |
Microsoft® Windows® 10 IoT Enterprise x64 |
|
|
|
|
|
|
Technical Data RM-GXP* and PC-GXP* |
|
|
|
|
|
|
|
Supply |
|
|
|
|
|
|
|
Power consumption |
|
|
|
|
|
|
|
AC |
115/230 V AC, 0.4 ... 0.7 A, 50/60 Hz |
|
|
|
|
|
|
DC |
18 ... 36 V DC , 1.5 ... 3 A |
|
|
|
|
|
|
|
|
|
|
Indicators/operating means |
|
|
|
|
|
|
|
Display |
|
|
|
|
|
|
|
Type |
Liquid Crystal Display (LCD) with LED back- |
|
|
|
light |
|
|
|
|
|
|
Screen diagonal |
54.61 cm (21.5 inch) |
|
|
|
|
|
|
Resolution |
1920 x 1080 pixels (Full HD) |
|
|
|
Aspect ratio 16:9 |
|
|
|
|
|
|
Color depth |
24 bit (16.7 M) color |
|
|
|
|
|
|
Contrast |
5000:1 (typically) |
|
|
|
|
|
|
Brightness |
300 cd/m |
2 |
|
|
|
|
|
|
|
|
|
Reading angle |
175° in all directions |
|
|
|
|
|
|
Life span |
back lamp life: 50.000 hrs typical half life , at |
|
|
|
25 °C (77 °F) |
|
|
|
|
|
|
Input devices |
|
|
|
|
|
|
|
Touchscreen |
optional: projective capacitive; 10 finger multi- |
|
|
|
touch, glove friendly |
|
|
|
|
|
|
Keyboard |
Foil keyboard with different pointing device |
|
<![if ! IE]> <![endif]>2020-04 |
|
options available (see EXTA2 datasheet) |
|
|
|
|
|
|
|
|
9
VisuNet GXP
Product Description
Interface
Interface type |
Standard: |
|
1 x Ethernet 100/1000BASE-TX (Ex e) or |
|
1 x fiber optic 1000BASE-SX (Multimode) or |
|
1 x fiber optic 1000BASE-LX (Singlemode), |
|
1 x USB 2.0 (Ex e), |
|
2 x USB 1.1 (Ex i; intended for Pepperl+Fuchs |
|
keyboard and mouse), |
|
1 x DC or AC power in (via power supply unit) |
|
Optional: |
|
1 x barcode reader interface Pepperl+Fuchs |
|
Pscan-D/B (Ex i) |
|
"interface 3": 1 x barcode reader interface for |
|
wired 1-D scanners IDM-160-D*, IDM-Z1- |
|
160-D-* and base station IDMx61-B-* and |
|
IDM-Z1-x61-B-* (Ex i) |
|
"interface 4": 1 x barcode reader interface for |
|
wired 2-D Scanner IDM-Z1-260-D-* (Ex i) |
|
"interface 5": 1 x RS-232 interface with Power |
|
Supply for miscellaneous devices and periph- |
|
erals (Ex i) |
|
1 x RS-485 (Ex e) |
|
1 x Ethernet 100/1000Base-TX (Ex e) Blue- |
|
tooth v4.0, communication distance up to 30 |
|
m in open terrain, transmission power +8 |
|
dBm, transmission frequency 2.402 ... 2.48 |
|
GHz |
|
|
|
|
Directive conformity |
|
|
|
Electromagnetic compatibility |
|
|
|
Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
|
non-Bluetooth products only |
|
|
Radio and telecommunication terminal equipment |
|
|
|
Directive 2014/53/EU |
EN 301 328 V2.1.1 |
|
EN 301 489-1 V2.1.1 |
|
EN 301 489-17 V3.1.1 |
|
Bluetooth products only |
|
|
RoHS |
|
|
|
Directive 2011/65/EU (RoHS) |
EN 50581:2012-09 |
|
|
|
|
Ambient conditions |
|
|
|
Operating temperature |
-20 ... 50 °C (-4 ... 122 °F) |
|
Display might react sluggishly below 0 °C |
|
|
Storage temperature |
-20 ... 60 °C (-4 ... 140 °F) |
|
|
Relative humidity |
93% at 40°C, non-condensating, according to |
|
EN60068-2-78 |
|
|
Altitude |
Operating altitude max. 2000 m |
|
|
Shock resistance |
18 shocks 15 g , 11 ms all axis, IEC 60068-2- |
|
27 |
|
|
Vibration resistance |
10 ... 150 Hz, +/- 0.075 mm , 1g, 10 cycles per |
|
axis according to EN60068-2-6 |
|
|
<![endif]>2020-04
10
VisuNet GXP
Product Description
Mechanical specifications
Degree of protection |
IP66 (individual components and entire sys- |
|
tem with housing) |
|
|
Material |
Internal: |
|
Panel: anodized aluminum (TCU, PCU, PSU), |
|
powder coated aluminum (DPU) |
|
External: |
|
Bezel: stainless steel AISI 304 (1.4301) |
|
System housing: stainless steel AISI 304 |
|
(1.4301), beat blasted, typical surface rough- |
|
ness Ra = 0.8 µm |
|
|
Installation |
Flush-mount installation (requires customized |
|
mounting kit) |
|
Panel-mount installation into system housing |
|
with bezel |
|
Panel-mount installation into cabinet with |
|
Bezel and standard mounting kit |
|
|
Mass |
Panel (DPU with bezel, TCU, PSU DC): |
|
approx. 23 kg\rPanel (DPU with bezel, TCU, |
|
PSU AC): approx. 24 kg\rSystem housing |
|
(AG-XX00): approx. 11 kg |
|
|
Dimensions |
Panel (DPU with bezel, TCU, PSU DC): 625 |
|
mm x 459 mm x 120 mm |
|
Panel (DPU with bezel, TCU, PSU AC): 625 |
|
mm x 459 mm x 137 mm |
|
Panel with system housing: 625 mm x 459 mm |
|
x 173 mm |
|
Panel cut-out dimensions: 583 mm x 417 mm |
|
(installation surface) |
|
|
|
|
Data for application in connection with hazardous areas |
|
|
|
EU-type examination certificate |
BVS 17 ATEX E 036 X |
|
|
Marking |
II 2G Ex eb q ib [ib] IIC T4 IP66 Gb |
|
|
|
II 2D Ex tb [ib] IIIC T85°C IP66 Db |
|
|
Directive conformity |
|
|
|
Directive 2014/34/EU |
EN 60079-0:2012+A11:2013, EN 60079- |
|
5:2015, EN 60079-7:2015, EN 60079- |
|
11:2012, EN 60079-31:2014 |
|
|
|
|
International approvals |
|
|
|
UL approval |
E492874 |
|
|
IECEx approval |
IECEx BVS 17.0029X |
|
|
Standards |
IEC 60079-0:2011, IEC 60079-5:2015, IEC |
|
60079-7:2015, IEC 60079-11:2011, IEC |
|
60079-31:2013 |
|
|
<![endif]>2020-04
11
VisuNet GXP
Product Description
Note
For more technical information, refer to the documentation for the individual components:
•Display Units DPU1100-J1* and DPU1200-J2*
•AC Power Supply Units PSU1100-J1-AC-N0 and PSU1200-J2-AC-N0
•DC Power Supply Units PSU1100-J1-DC-N0 and PSU1200-J2-DC-N0
•Thin Client Units TCU1100-J1-* and TCU1200-J2-*
•Personal Computer Units PCU1100-* and PCU1200-*
•Peripherals such as keyboards or barcode readers
Marking
ATEX |
|
|
|
|
|
RM-GXP1100-J1-* |
II 2G Ex eb q ib [ib] IIC T4 IP66 Gb |
|
PC-GXP1100-J1-* |
||
II 2D Ex tb [ib] IIIC T85°C IP66 Db |
||
|
||
|
|
|
RM-GXP1200-J2-* |
II 3G Ex ec [ib] q IIC T4 IP66 Gc |
|
PC-GXP1200-J2-* |
||
II 3D Ex tc [ib] IIIC T85 °C IP66 Dc |
||
|
||
|
|
|
|
|
|
IECEx |
|
|
|
|
RM-GXP1100-J1-* |
Ex eb q ib [ib] IIC T4 IP66 Gb |
PC-GXP1100-J1-* |
Ex tb [ib] IIIC T85°C IP66 Db |
|
|
RM-GXP1200-J2-* |
Ex ec [ib] q IIC T4 IP66 Gc |
PC-GXP1200-J2-* |
Ex tc [ib] IIIC T85 °C IP66 Dc |
UL
<![if ! IE]><![endif]>2020-04
12
VisuNet GXP
Product Description
2.3Dimensions
Note
For more options and information, refer to the VisuNet GXP Mounting Options datasheet.
Pedestal Mount
625 |
|
|
1 |
~ 400 |
|
|
|
2 |
~ 400 |
<![if ! IE]> <![endif]>451 |
|
|
|
459 |
|
|
|
|
459 |
|
|
|
|
|
|
|
|
|
|
|
|
|
173 |
|
|
|
|
173 |
|
<![if ! IE]> <![endif]>(1687) |
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>1236 |
|
|
|
|
|
|
|
|
|
ø 165 |
<![if ! IE]> <![endif]>214 |
|
|
<![if ! IE]> <![endif]>45° |
<![if ! IE]> <![endif]>263 |
<![if ! IE]> <![endif]>204 |
|
|
<![if ! IE]> <![endif]>45° |
|
<![if ! IE]> <![endif]>154 |
<![if ! IE]> <![endif]>104 |
<![if ! IE]> <![endif]>154 |
<![if ! IE]> <![endif]>104 |
VisuNet GXP system H1 housing installed into AG-XX00 housing with additional PEDESATAL- XX00-* pedestals and EXTA2-* keyboard inside an -F housing with -G mounting version (1-Arm for mounting to AG-XX00 housing)
1 |
Shown with PEDESTAL-XX00-124-3-304-TRN-N0 |
|
|
2 |
Shown with PEDESTAL-XX00-124-4-304-TRN-N0 |
|
|
Note
EXTA2-* keyboard and PEDESTAL-XX00-* pedestals must be ordered separately.
<![if ! IE]><![endif]>2020-04
13
VisuNet GXP
Product Description
Wall Mount |
|
625 |
|
<![if ! IE]> <![endif]>451 |
|
|
<![if ! IE]> <![endif]>635 |
|
8 |
582 |
256 |
|
450 |
Figure 2.3 VisuNet GXP system H1 housing installed into AG-XX00 housing with additional WALL- BRACKET-XX00-3-304-N0 and EXTA2 keyboard inside an -F housing with -G mounting version (1-Arm for mounting to AG-XX00 housing)
Wall Mount Hole Pattern
Figure 2.4
<![endif]>2020-04
14
VisuNet GXP
Product Description
Panel Mount
633
23.5 |
584 |
17.3 |
114 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>418 |
<![if ! IE]> <![endif]>467 |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 2.5 VisuNet GXP system S1 housing including bezel, prepared for panel mounting, with KIT- PM-XX00-22F-304-N0 kit for panel mounting
<![if ! IE]><![endif]>2020-04
15
VisuNet GXP
Mechanical Installation
3Mechanical Installation
3.1Unpacking
Warning!
Risk of injury
Handling the VisuNet GXP components without gloves may cut fingers, hands, or wrists.
Wear gloves at all times during installation.
The VisuNet GXP comes with its core components preassembled. These components consist of a display unit (DPU), power supply unit (PSU), and thin client unit (TCU) or PC unit (PCU). If the housing option is chosen, the components come pre-mounted into the housing.
Figure 3.1 VisuNet GXP in the box
Caution!
Scratches and damage
GXP components may become scratched or damaged if they are placed onto or slid across hard surfaces.
Warning!
Danger resulting from scratched DPU screen
Scratches in the DPU screen weaken the glass structure. This may result in glass breakage in the event of an explosion. Explosion protection is no longer ensured if a DPU with a scratched screen is used.
NEVER use a DPU with a scratched screen in a hazardous area. If the surface is damaged in any way, return the DPU to Pepperl+Fuchs at once and replace it with a new one. See chapter 3.3.12 for information about removing the DPU.
<![if ! IE]><![endif]>2020-04
16
VisuNet GXP
Mechanical Installation
Using Foam Brackets During Installation
Figure 3.2 To help protect the VisuNet GXP components once they have been removed from the box, use the enclosed foam brackets.
<![endif]>2020-04
Figure 3.3 To protect the DPU front screen, place the VisuNet GXP face down onto the foam brackets.
17
VisuNet GXP
Mechanical Installation
3.2Electrical Installation
Warning!
Danger of Explosion
Cable insulation may become damaged if cables and connection lines are not used in adequate temperature ranges. Thus, short circuits within the cable may occur which in turn may give rise to sparks and/or surface temperatures capable of triggering an ignition.
Only use cables and connection lines which are suitable to be used within a temperature rating of 80 °C if the system components are used within an ambient operating temperature of Ta > 40
°C.
Note
Refer to the manuals of the individual VisuNet GXP components for more information on electrical installation and wiring.
Danger!
Explosion hazard from wrong or missing grounding
Wrong or missing grounding can cause sparks. This can ignite the surrounding potentially explosive atmosphere.
•Ground the device. Observe the grounding requirements.
•Ensure that external ground connections exist, are in good condition, and are not damaged or corroded.
Warning!
Risk of electric shock or property damage from inadequate grounding
If you do not ground the device correctly, this could result in potential equalization currents. These currents could hurt operating personnel or cause property damage.
Ground the device via the grounding bolt. Ensure that a correct potential equalization is guaranteed at all times.
When installing the VisuNet GXP system, always ensure a proper grounding of all components, including housing and mounting parts (e.g., pedestal and wall bracket) with a cable diameter of
at least 4 mm2in accordance with IEC 60079-14.
The VisuNet GXP is shipped with the following protective earth (PE) wiring connections, if the AG-XX00 housing option is selected:
•PE wire from the DPU PE stud to the AG-XX00 housing PE stud.
•PE wire from the PSU PE stud to the AG-XX00 housing PE stud.
3.3System Installation
3.3.1General Installation Information
Observe the following requirements when installing the system components.
• The equipment must be installed by competent personnel in accordance with the instructions. National laws and regulations must be observed.
• The building installation must provide a 20 A overcurrent protection. |
|
|
• |
The installer must make a readily accessible disconnect device available. |
|
• |
The safety of any system incorporating the PSU is the responsibility of the assembler of |
<![if ! IE]> <![endif]>2020-04 |
|
the system. |
|
|
|
18