Pepperl Fuchs RM-GXP1100-19S, RM-GXP1200-19S, PC-GXP1100-19S, PC-GXP1200-19S Instruction manual

VisuNet GXP
RM-GXP1100-19S RM-GXP1200-19S PC-GXP1100-19S PC-GXP1200-19S
Manual
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietor­ship"
Worldwide
Pepperl+Fuchs Group
Lilienthalstr. 200
68307 Mannheim
Germany
Phone: +49 621 776 - 0
E-mail: info@de.pepperl-fuchs.com
North American Headquarters
Pepperl+Fuchs Inc.
1600 Enterprise Parkway
Twinsburg, Ohio 44087
USA
Phone: +1 330 425-3555
E-mail: sales@us.pepperl-fuchs.com
Asia Headquarters
Pepperl+Fuchs Pte. Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Phone: +65 6779-9091
E-mail: sales@sg.pepperl-fuchs.com
https://www.pepperl-fuchs.com
VisuNet GXP
Contents
1 Introduction................................................................................................................ 4
1.1 Content of this Document............................................................................. 4
1.2 Target Group, Personnel ............................................................................... 4
1.3 Symbols Used ................................................................................................ 5
2 Product Description ..................................................................................................6
2.1 Overview......................................................................................................... 6
2.2 Technical Specifications ............................................................................... 9
2.3 Dimensions................................................................................................... 12
2.4 Disposal........................................................................................................ 14
3 Mechanical Installation ........................................................................................... 15
3.1 General Installation Requirements ............................................................ 15
3.2 Installation Tools.......................................................................................... 15
3.3 System Installation ......................................................................................16
3.3.1 Preparation for System Installation................................................... 16
3.3.2 Preparing the GXP Panel/Housing................................................... 17
3.3.3 Preparing the StandardLine Pedestal .............................................. 20
3.3.4 Attaching the Pedestal to the Housing ............................................. 24
3.3.5 Opening the Housing ....................................................................... 27
3.3.6 Grounding the Housing to the Pedestal ........................................... 29
3.3.7 Mounting the Keyboard.................................................................... 31
3.3.8 Mounting the Scanner Holder to the AG1 Housing .......................... 33
3.3.9 Installing the Handheld 1-D/2-D Code Reader................................. 37
3.4 Replacing a VisuNet EX1 with the 19-Inch VisuNet GXP..........................43
3.4.1 Removing VisuNet EX1 from AG1 Housing...................................... 44
3.4.2 Installing VisuNet GXP into AG1 Housing ........................................ 46
3.5 Panel Mount Installation .............................................................................49
3.6 Wall Mount Installation................................................................................ 52
4 Appendix .................................................................................................................. 54
4.1 Accessories.................................................................................................. 54
4.2 UL Control Drawing ..................................................................................... 55
2020-04
3
VisuNet GXP
Introduction
1 Introduction
1.1 Content of this Document
This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following:
Product identification
Delivery, transport, and storage
Mounting and installation
Commissioning and operation
Maintenance and repair
Troubleshooting
Dismounting
Disposal
Note
This document does not substitute the instruction manual.
Note
For full information on the product, refer to the instruction manual and further documentation on the Internet at www.pepperl-fuchs.com.
The documentation consists of the following parts:
Present document
Instruction manual
Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
EU-type examination certificate
EU declaration of conformity
Attestation of conformity
Certificates
Control drawings
Additional documents
1.2 Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismount­ing lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, com­missioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
4
2020-04
VisuNet GXP
Introduction
1.3 Symbols Used
This document contains symbols for the identification of warning messages and of informative messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid prop­erty damage.
Depending on the risk level, the warning messages are displayed in descending order as fol­lows:
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure.
Informative Symbols
Note
This symbol brings important information to your attention.
Action
This symbol indicates a paragraph with instructions. You are prompted to perform an action or a sequence of actions.
2020-04
5
VisuNet GXP
Product Description
2 Product Description
2.1 Overview
The Pepperl+Fuchs VisuNet Remote Monitors GXP RM-GXP1100-19S*/RM-GXP1200-19S* and PC-GXP-1100-19S*/PC-GXP-1200-19S* are ATEX/IECEx certified, UL listed devices intended for use in potentially explosive atmospheres, such as Zones 1/21, 2/22 and Class I Div. 2, Class II Div. 2, and Class III.
The VisuNet GXP serves as a thin client- or PC-based operator workstation that uses standard Ethernet technology to transmit process information from a process control or manufacturing execution system into hazardous areas.
The assembly consists of several core devices that can be exchanged by the customer:
The display units DPU1100-* and DPU1200-* are display panels with optional 10-finger
multi-touch sensors. The displays and touch-sensors are optically bonded with the hard­ened front glass.
The thin client units TCU1100-* and TCU1200-* are computing units running the latest
Pepperl+Fuchs RM Shell 5.x or RM Shell 4.x firmware. They allow connectivity to various host systems in the safe area using standard Ethernet technology. The computing units PCU1100-* and PCU1200-* run an open Microsoft® Windows® operating system, allow­ing installation of any software, such as SCADA packages.
The power supply units PSU1100-* and PSU1200-* provide the above-listed devices with
24 V DC power. They are available as DC and AC versions.
As the standard mounting option, a bezel is available that allows the panel to be mounted into a system housing or cabinet that needs to be ordered separately. The panel can also be flush­mounted into a cabinet from behind.
2020-04
6
VisuNet GXP
1
2
3
4
Product Description
VisuNet GXP Panel Components
Figure 2.1 VisuNet GXP panel components
1 Bezel for housing and panel mounting
2 Computing unit (TCU or PCU): processor, SSD and memory, Ex circuits,
interface modules
3 Power supply unit: DC or AC option, backpacked (panel-mount) or stand-
alone (in system enclosure)
4 Display unit: display, touch screen, hardened front glass
2020-04
7
VisuNet GXP
Product Description
VisuNet GXP Pedestal Mounted with Keyboard/Mouse
Figure 2.2 VisuNet GXP system mounted in AG1 Housing with Pedestal5 -1458-* and EXTA2
keyboard/mouse (ordered separately)
Note
For a description of the product model nomenclature, see the VisuNet GXP PC or VisuNet GXP RM product datasheets at www.pepperl-fuchs.com.
For more mounting options and information, see the datasheet "Mounting Options 'StandardLine' and 'BasicLine'".
2020-04
8
VisuNet GXP
Product Description
2.2 Technical Specifications
Technical Data RM-GXP*
Hardware
Processor Intel® Atom Bay Trail E3827 1.75 GHz
RAM 2048 MB DDR3L
Mass storage 32 GByte industrial grade MLC SSD
Software
Operating system VisuNet RM Shell 5.x (based on Microsoft®
Technical Data PC-GXP*
Hardware
Processor Intel® Atom Bay Trail E3845 1.91 GHz
RAM 4096 MB DDR3L
Mass storage 128 GByte industrial grade MLC SSD
Windows® 10 IoT LTSB)
Software
Operating system Microsoft® Windows® 10 IoT Enterprise x64
Technical Data RM-GXP* and PC-GXP*
Supply
Power consumption
AC 115/230 V AC, 0.4 ... 0.7 A, 50/60 Hz
DC 18 ... 36 V DC , 1.5 ... 3 A
2020-04
9
VisuNet GXP
Product Description
Interface
Interface type 1 x Ethernet 100/1000BASE-TX (Ex e) or
1 x fiber optic 1000BASE-SX (Multimode) or 1 x fiber optic 1000BASE-LX (Singlemode) 1 x USB 2.0 (Ex e) 2 x USB 1.1 (Ex i; intended for Pepperl+Fuchs keyboard and mouse) 1 x DC or AC power in (via power supply unit)
Optional:
1 x barcode reader interface Pepperl+Fuchs Pscan-D/B (Ex i) "interface 3": 1 x barcode reader interface for wired 1-D scanners IDM-160-D*, IDM-Z1­160-D-* and base station IDMx61-B-* and IDM-Z1-x61-B-* "interface 4": 1 x barcode reader interface for wired 2-D Scanner IDM-Z1-260-D-* (Ex i) "interface 5": 1 x RS-232 interface with Power Supply for miscellaneous devices and periph­erals (Ex i) 1 x RS-232 (Ex e) 1 x RS-485 (Ex e) 1 x Ethernet 100/1000Base-TX (Ex e) Bluetooth v4.0, communication distance up to 30 m in open terrain, transmission power +8 dBm, transmission frequency 2.402 ... 2.48 GHz
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
RoHS
Directive 2011/65/EU (RoHS) EN 50581:2012-09
Ambient conditions
Operating temperature -20 ... 50 °C (-4 ... 122 °F)
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
Relative humidity 93% at 40°C, non-condensating, according to
Altitude Operating altitude max. 2000 m
Shock resistance 18 shocks 15 g , 11 ms all axis, IEC 60068-2-
Vibration resistance 10 ... 150 Hz, +/- 0.075 mm , 1g, 10 cycles per
non-Bluetooth products only
EN60068-2-78
27
axis according to EN60068-2-6
10
2020-04
VisuNet GXP
Product Description
Mechanical specifications
Degree of protection IP66 (individual components and entire sys-
Material Internal:
Mass panel with DC: 22 kg , panel with AC: 23 kg ,
Dimensions panel with DC: 524 mm x 453 mm x 120 mm
Note
For more technical information, refer to the manuals and instruction manuals of the individual components:
Display Units DPU1100-J1* and DPU1200-J2*
AC Power Supply Units PSU1100-J1-AC-N0 and PSU1200-J2-AC-N0
DC Power Supply Units PSU1100-J1-DC-N0 and PSU1200-J2-DC-N0
tem with housing)
Panel: anodized aluminum (TCU, PSU), pow­der coated aluminum (DPU) External: Bezel: stainless steel AISI 304 (1.4301) System housing: stainless steel AISI 304 (1.4301), ground smooth, typical surface roughness Ra = 0.8 µm
system housing AG1: 19 kg
panel with AC: 524 mm x 453 mm x 137 mm panel with AG1 housing: 582 mm x 490 mm x 224 mm
Thin Client Units TCU1100-J1-* and TCU1200-J2-*
Computing Units PCU1100-J1-* and PCU1200-J2-*
Marking
ATEX
RM-GXP1100-J1-*
RM-GXP1200-J2-*
IECEx
RM-GXP1100-J1-* Ex eb q ib [ib] IIC T4 IP66 Gb
RM-GXP1200-J2-* Ex ec [ib] q IIC T4 IP66 Gc
II 2G Ex eb q ib [ib] IIC T4 IP66 Gb II 2D Ex tb [ib] IIIC T85°C IP66 Db
II 3G Ex ec [ib] q IIC T4 IP66 Gc II 3D Ex tc [ib] IIIC T85 °C IP66 Dc
Ex tb [ib] IIIC T85°C IP66 Db
Ex tc [ib] IIIC T85 °C IP66 Dc
UL Marking
2020-04
11
VisuNet GXP
582
490
1702
228
475
1100
Product Description
2.3 Dimensions
Dimensions with AG1 Housing and Pedestal
Figure 2.3 Dimensions with StandardLine Pedestal5-1458-Fix and EXTA2 keyboard/mousesample
configuration
Note
Keyboard/mouse and pedestal are ordered separately.
12
2020-04
VisuNet GXP
524
137
453
499
480
167
419
400
270
Ø 6.5
± 0.5 (14 x)
Product Description
Panel Dimensions with Bezel
Panel Cut-Out Dimensions
Cut-out dimensions: 480 x 400 mm. For more information, see chapter 3.5.
2020-04
13
VisuNet GXP
490
582
583
62
532
285
686
413
Product Description
Wall Mount Dimensions
Figure 2.4 Wall mount dimensions with additional wall brackets (#198768)
2.4 Disposal
Follow all local and any other requirements for disposing of electronic equipment. When dis­posing of any system component, mark VOID across all certification labels.
2020-04
14
VisuNet GXP
Mechanical Installation
3 Mechanical Installation
3.1 General Installation Requirements
Observe the following requirements when installing the system components.
The equipment must be installed by competent personnel in accordance with the instruc-
tions. National laws and regulations must be observed.
The building installation must provide a 20 A overcurrent protection.
The installer must make a readily accessible disconnect device available.
The safety of any system incorporating the power supply unit is the responsibility of the
assembler of the system.
3.2 Installation Tools
4-mm and 5-mm torque Allen keys
Open-ended wrench for cable glands
Screws for floor or wall mounting. Choose the appropriate screws based on the mounting
conditions.
Small cable ties
Side cutters
Strong adhesive tape, such as duct tape or packing tape
At least 1 piece of thin, 2.5-m-long wire for pulling cables through the pedestal
Warning!
Risk of injury
Lifting the device on your own may lead to injury.
Do not attempt to lift the device on your own. Use a crane or have another person help you.
2020-04
15
VisuNet GXP
Mechanical Installation
3.3 System Installation
3.3.1 Preparation for System Installation
Warning!
Proper installation on the floor
It is the installer's responsibility to select a suitable location with sufficient strength to hold the equipment. It is the installer's responsibility to select the proper screws based on the installa­tion conditions.
Warning!
Distance between housing and wall
Provide at least 350 mm of space between the housing/pedestal assembly and the left wall. This is required in order to properly open the housing and connect the GXP components.
16
Figure 3.1 Distance required between housing/pedestal assembly and wall
2020-04
VisuNet GXP
400
180 180
300
250
140
130
130
20
40
Ø 100
Ø 10
071
031
130
170
90
45°
1
0
184
Mechanical Installation
StandardLine Pedestal Floor-Mount Hole Pattern
BasicLine Pedestal Floor-Mount Hole Pattern
3.3.2 Preparing the GXP Panel/Housing
The VisuNet GXP comes pre-assembled and consists of the core components display unit, power supply unit, and thin client unit / power supply unit. If the AG1 housing option is chosen, the panel is pre-mounted in the housing.
Required Components
1 x pre-assembled VisuNet RM-GXP or PC-GXP panel (option: panel-mounted into AG1
housing)
2020-04
2 x protective tubes
Screws for housing
EXTA2 keyboard and PEDESTAL5-xxxx-* (ordered separately)
Warning!
Risk of injury
Handling the devices with bare hands may cut fingers, hands, or wrists.
Wear gloves at all times during the installation process.