Pepperl Fuchs PXV100S-F200-SSI-V19 Data Sheet

Optical reading head PXV100S-F200-SSI-V19
Technical data
General specifications
Passage speed v 8 m/s Measuring range max. 10000 m
Model number
PXV100S-F200-SSI-V19
Read head for incident light positioning system
Features
•SSI interface
• Non-contact positioning on Data Matrix code tape
• Mechanically rugged: no wearing parts, long operating life, maintenance-free
• High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
• Travel ranges up to 10 km
Diagramms
Position Data
Y
000 009.0 m PXV-AA25
X
Read distance 100 mm Depth of focus + 20 mm / - 40 mm Reading field 115 mm x 73 mm Ambient light limit 100000 Lux Accuracy ± 0.2 mm
Nominal ratings
Camera
Type CMOS , Global shutter
Processor
Clock pulse frequency 600 MHz Speed of computation 4800 MIPS
Functional safety related parameters
MTTFd 87 a Mission Time (T Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED indicator 7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage U No-load supply current I Power consumption P
Interface 1
Interface type SSI interface Data output code Gray code, binary code , programmable Monoflop time Tm = 10 µs
Clock frequency 100 ... 1000 kHz Query cycle time 3 ms Pause time tp 20 µs
Interface 2
Interface type USB (serial comport) Protocol 8E1 Transfer rate 38.4 ... 460.8 kBit/s
Input
Input type 1 to 2 functional inputs , programmable Input impedance 27 k
Output
Output type 1 to 2 switch outputs , PNP , programmable , short-circuit
Switching voltage Operating voltage Switching current 150 mA each output
Standard conformity
Emitted interference EN 61000-6-4:2007+A1:2011 Noise immunity EN 61000-6-2:2005 Shock resistance EN 60068-2-27:2009 Vibration resistance EN 60068-2-6:2008
Ambient conditions
Operating temperature 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -20 ... 85 °C (-4 ... 185 °F) Relative humidity 90 % , noncondensing
Mechanical specifications
Connection type 8-pin, M12 x 1 connector Housing width 70 mm Housing height 70 mm Housing depth 50 mm Degree of protection IP67 Material
Housing PC/ABS
Mass approx. 170 g
) 43 a
M
B
0
0
-1
100 s
15 ... 30 V DC , PELV max. 200 mA 3 W
double request possible, if t
protected
(noncondensing; prevent icing on the lens!)
10 µs
p
System components
PXV*-CA25-*
Data Matrix code tape
Release date: 2018-07-05 10:39 Date of issue: 2018-07-05 293431-100002_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source,
CCC approval CCC approval / marking not required for products rated ≤36
Type 1 enclosure
V
1
PXV100S-F200-SSI-V19Optical reading head
Dimensions
9
Additional information
4 x M6
51
ø 25
22
7
1
2
6
3
8
5
4
1
70
80
3
2
4
8
1
5
7
6
2
M12 x 1
12
40
38.5
ADJUST
CONFIG
COM SERVICE
70 14.5
LED 1 2 3 4 5 6 7
1
2
SSI DATA / CONFIG
OUT2 / ADJ Y
PWR / ADJ
ERR / NO CODE
OUT3 / ADJ Z
DIAGNOSTIC
INTERNAL
Electrical connection
Pinout
Accessories
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data +
Data -
CLK+
CLK-
GND
OUT 3 / IN 3
8
2
1
7
6
V19-G-ABG-PG9
Female connector, M12, 8-pin, shielded, field attachable
V19-G-ABG-PG9-FE
Female connector, M12, 8-pin, shielded, field attachable
PCV-KBL-V19-STR-USB
USB cable unit with power supply
PCV-SC12
Grounding clip for PCV system
PCV-LM25
Marker head for 25 mm code tape
PCV-MB1
Mounting bracket for PCV* read head
PCV-AG100
Alignment guide for PCV100-* read head
Vision Configurator
Operating software for camera-based sensors
53
4
General
The reader forms part of the positioning system in the Pepperl+Fuchs incident light process. The reader's features include a camera module and an integrated illumination unit, enabling it to detect position markers printed onto an adhesive code tape in the form of Data Matrix codes. Generally speaking, the code tape is mounted stationary on a fixed part of the plant (e.g., elevator shaft, overhead conveyor mounting rails) and the reader is mounted parallel on the moving "vehicle" (e.g., elevator car, overhead conveyor chassis).
Mounting and Commissioning
Mount the reader such that the optical surface of the device captures the optimal reading distance to the code tape (see "Technical Data"). The stability of the mounting and the manner in which the vehicle is guided ensure that the