Optical reading head PXV100-F200-R4-V19
Technical data
General specifications
Passage speed v ≤ 8 m/s
Measuring range max. 10000 m
Model number
PXV100-F200-R4-V19
Read head for incident light positioning
system
Features
• RS-485 interface
• Non-contact positioning on Data
Matrix code tape
• Mechanically rugged: no wearing
parts, long operating life,
maintenance-free
• High resolution and precise
positioning, especially for facilities
with curves and switch points as well
as inclines and declines.
• Travel ranges up to 10 km
Diagramms
Position Data
Y
000 009.0 m PXV-AA25
X
System components
PXV*-CA25-*
Data Matrix code tape
Light type Integrated LED lightning (red)
Scan rate
Read distance 100 mm
Depth of focus ± 50 mm
Reading field 115 mm x 73 mm
Ambient light limit 100000 Lux
Accuracy ± 0.2 mm
Nominal ratings
Camera
Type CMOS , Global shutter
Processor
Clock pulse frequency 600 MHz
Speed of computation 4800 MIPS
Functional safety related parameters
MTTFd 100 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED indicator 7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage U
No-load supply current I
Power consumption P
Interface
Interface type RS 485 interface
Data output code binary code
Transfer rate 38400 ... 230400 Bit/s
Termination Switchable terminal resistor
Query cycle time ≥ 10 ms
Interface 2
Interface type USB Service
Input
Input type 1 to 3 functional inputs , programmable
Input impedance ≥ 27 kΩ
Output
Output type 1 to 3 switch outputs , PNP , programmable , short-circuit
Switching voltage Operating voltage
Switching current 150 mA each output
Standard conformity
Emitted interference EN 61000-6-4:2007+A1:2011
Noise immunity EN 61000-6-2:2005
Shock resistance EN 60068-2-27:2009
Vibration resistance EN 60068-2-6:2008
Ambient conditions
Operating temperature 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -20 ... 85 °C (-4 ... 185 °F)
Relative humidity 90 % , noncondensing
Mechanical specifications
Connection type 8-pin, M12 x 1 connector
Housing width 70 mm
Housing height 70 mm
Housing depth 50 mm
Degree of protection IP67
Material
Housing PC/ABS
Mass approx. 160 g
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source,
CCC approval CCC approval / marking not required for products rated ≤36
) 50 a
M
B
0
0
-1
40 s
15 ... 30 V DC , PELV
max. 200 mA
3 W
protected
(noncondensing; prevent icing on the lens!)
Type 1 enclosure
V
Release date: 2018-06-28 09:48 Date of issue: 2018-06-28 293431-100001_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

PXV100-F200-R4-V19Optical reading head
Dimensions
9
Additional information
4 x M6
51
ø 25
22
4
5
8
3
6
2
1
7
70
80
1
2
38.5
70 14.5
M12 x 1
12
ADJUST
CONFIG
COM
LED 1 2 3 4 5 6 7
1
2
OUT1
OUT2 / ADJ Y
PWR / ADJ
ERR / NO CODE
OUT3 / ADJ Z
DIAGNOSTIC
INTERNAL
Electrical connection
Pinout
Accessories
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data+ / TX / 485+
Data- / RX / 485-
OUT 1
IN 1
GND
OUT 3 / IN 3
1
8
2
4
7
6
53
PCV-USB-RS485-Converter Set
USB to RS 485 interface converter
PCV-KBL-V19-STR-RS485
Cable unit with power supply for USB /
RS-485 interface converter
V19-G-ABG-PG9
Female connector, M12, 8-pin, shielded,
field attachable
V19-G-ABG-PG9-FE
Female connector, M12, 8-pin, shielded,
field attachable
PCV-SC12
Grounding clip for PCV system
PCV-LM25
Marker head for 25 mm code tape
PCV-MB1
Mounting bracket for PCV* read head
PCV-AG100
Alignment guide for PCV100-* read head
Vision Configurator
Operating software for camera-based
sensors
General
The reading head is part of the positioning system in the method for measurement by Pepperl+Fuchs. It consists of a camera module and an integrated illumination unit among other
things. The reading head detects position marks, which are put on an adhesive code band in
the form of Data Matrix code. The mounting of the code band is as a rule stationary on a firm
part of the plant (elevator shaft, overhead conveyor mounting rails…); that of the reading head
is parallel on the moving "vehicle" (elevator car, overhead conveyor chassis…).
Mounting and commissioning
Mount the reading head such that its optical surface captures the optimal read distance to the
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2018-06-28 09:48 Date of issue: 2018-06-28 293431-100001_eng.xml