Pepperl Fuchs PMI80-F90-IU-V1 Data Sheet

Inductive positioning system PMI80-F90-IU-V1
Technical data
General specifications
Switching element function analog, current or voltage output Object distance 0.5 ... 3 mm , recommended: 2 mm Measurement range 0 ... 80 mm Linearity range 1 ... 79 mm
Nominal ratings
Model Number
PMI80-F90-IU-V1
Features
• Analog output 0 V ... 10 V/4 mA ... 20 mA
• Measuring range 0 ... 80 mm
Operating voltage U Reverse polarity protection reverse polarity protected Linearity error within measuring range: ± 0.8 mm
Repeat accuracy R ± 0.1 mm Resolution 125 µm Temperature drift ± 0.5 mm (-25 °C ... 70 °C) No-load supply current I Operating voltage indicator LED green
Functional safety related parameters
MTTFd 419 a Mission Time (T Diagnostic Coverage (DC) 0 %
Analog output
Output type 1 current output: 4 ... 20 mA
Load resistor current output: 400
Short-circuit protection voltage output: pulsing
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type 4-pin, M12 x 1 connector Degree of protection IP67 Material
Housing ABS Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source CCC approval CCC approval / marking not required for products rated 36 V
B
0
) 20 a
M
18 ... 30 V DC
within linearity range: ± 0.4 mm
40 mA
1 voltage output: 0 ... 10 V
voltage output: 1000
IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003
Dimensions
LED Power
Electrical Connection
IU
I
Core colours in accordance with EN 60947-5-2.
10 V/20 mA
I U
1
(BN)
4
(BK)
2
(WH)
3
(BU)
M12 x 1
83
102
0 V/4 mA
63
+ UB
4 - 20 mA 0 - 10 V
- UB
41
2223
M5 (2x)
Release date: 2014-09-02 09:58 Date of issue: 2016-03-17 191134_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive positioning system PMI80-F90-IU-V1
Pinout
1
2
3
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
Accessories
BT-F90-W
Damping element; lateral screw holes
MH-F90
Mounting bracket for mounting of F90 sensors
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
Additional Information
dimensions for the target object:
8
≥ 18
4
10 V/20 mA
Linearity range
Measuring range
≥ 4
0 V/4 mA
Operating instructions
• Safety information
Warni ng
• Sensor versions
The F90 linear position measurement system is available in 2 versions. In the PMI...-F90-IU-V1 version, the position measuring system transmits current and voltage signals pro­portional to the position of the damping element at the outputs. The PMI...-F90-IE8-V15 version offers a current signal as well as the option of teaching in two switching points directly at the sensor independently of one another at the press of a button, which is then indicated on two switching outputs. Two additional LEDs indicate the output states of the two switching outputs.
Version PMI…-F90-IU-V1
Output signals: 4 mA ... 20 mA and 0 V ... 10 V
Version PMI…-F90-IE8-V15
Output signals: 4 mA ... 20 mA and 2 programmable switching amplifiers
• Programming the PMI…-F90-IE8-V15
The rear of the PMI...-F90-IE8-V15 sensor has two small, slightly recessed push buttons for programming the switching points. The buttons are marked "teach in" and S1 for switching point S1 and S2 for switching point S2. To teach in a switching point, proceed as follows:
- The position detection damping element must be placed at the relevant position, i.e. the switching point that you wish to teach in.
- Press the corresponding push button for at least two seconds. The associated switching state LED starts flashing to indicate that the sensor is now in “teach mode”.
- Press the button again to confirm the relevant switching point. The switching state LED then lights up constantly as long as the damping element is not moved.
The switching point is now taught in and the associated switching point changes to an active state within an actuator adjustment range of ± 1 mm around the taught switching point.
• Damping element
The linear position measurement system is adapted perfectly to the geometry of the damping elements offered in our product range.
Note
• Installation and operation
This product may not be used in applications where personal safety depends on the function of the device. This product is not a safety component as described in EU Machinery Direc­tive.
Only the current output or the voltage output may be used. The unused output must remain load free.
Note
If the switching point is not confirmed within 80 seconds, the sensor exits “teach mode” and continues operation with the previous values.
Note
When using other damping elements, always make sure that the active surface of the damping element has a width of exactly 8 mm and covers the entire width of the sensor.
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
≥ 18
8
≥ 4
2
Release date: 2014-09-02 09:58 Date of issue: 2016-03-17 191134_eng.xml
Loading...