Inductive positioning system PMI80-F90-IE8-V15
Technical data
General specifications
Switching element function Analog current output with PNP binary NO
Object distance 0.5 ... 3 mm , recommended: 2 mm
Measurement range 0 ... 80 mm
Linearity range 1 ... 79 mm
Nominal ratings
Model Number
PMI80-F90-IE8-V15
Features
• Analog output 4 mA ... 20 mA
• Adjustable switch points
• Measuring range 0 ... 80 mm
Operating voltage U
Reverse polarity protected reverse polarity protected
Linearity error within measuring range: ± 0.8 mm
Repeat accuracy ± 0.1 mm
Resolution 125 µm
Temperature drift ± 0.5 mm (-25 °C ... 70 °C)
No-load supply current I
Operating voltage display LED green
Functional safety related parameters
MTTFd 300 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Switching output
Output type 2 switch outputs PNP, NO , reverse polarity protected ,
Operating current I
Switching window ± 1 mm
Switching hysteresis 0.4 mm
Voltage drop ≤ 3 V
Short-circuit protection pulsing
Analog output
Output type 1 current output: 4 ... 20 mA
Load resistor ≤ 400 Ω
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type M12 x 1 connector, 5-pin
Protection degree IP67
Material
Housing ABS
Target structural steel, e. g. 1.0037, SR235JR (formerly St37-2)
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007
B
0
) 20 a
M
L
18 ... 30 V DC
within linearity range: ± 0.4 mm
≤ 40 mA
short-circuit protected
≤ 100 mA
IEC 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CCC approval Products with a maximum operating voltage of ≤36 V do
not bear a CCC marking because they do not require
approval.
Dimensions
LED
4 mA
Button
41
2223
S2S1
M5 (2x)
S1S2
63
20 mA
M12 x 1
LED Power
83
102
Release date: 2012-05-30 16:55 Date of issue: 2012-05-30 191137_eng.xml
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
• Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://
1

Inductive positioning system PMI80-F90-IE8-V15
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
5 GY
IE8
Additional Information
dimensions for the target object:
1
2
5
2
4
3
1
3
(brown)
(white)
(blue)
(black)
(gray)
I
+ UB
4-20 mA
Q S1
Q S2
- UB
5
4
10 V/20 mA
8
≥ 18
Linearity range
Measuring range
≥ 4
0 V/4 mA
Accessories
BT-F90-W
Damping element for F90 sensors; lateral screw holes
MH-F90
Mounting bracket for mounting of F90 sensors
V15-G-2M-PVC
Cable socket, M12, 5-pin, PVC cable
V15-W-2M-PVC
Cable socket, M12, 5-pin, PVC cable
Operating instructions
• Safety information
Warni ng
• Sensor versions
The F90 linear position measurement system is available in 2 versions.
In the PMI...-F90-IU-V1 version, the position measuring system transmits current and voltage signals proportional to the position of the damping element at the outputs.
The PMI...-F90-IE8-V15 version offers a current signal as well as the option of teaching in two switching
points directly at the sensor independently of one another at the press of a button, which is then indicated
on two switching outputs. Two additional LEDs indicate the output states of the two switching outputs.
Version PMI…-F90-IU-V1
Output signals: 4 mA ... 20 mA and 0 V ... 10 V
Note
Version PMI…-F90-IE8-V15
Output signals: 4 mA ... 20 mA and 2 programmable switching amplifiers
• Programming the PMI…-F90-IE8-V15
The rear of the PMI...-F90-IE8-V15 sensor has two small, slightly recessed push buttons for programming
the switching points. The buttons are marked "teach in" and S1 for switching point S1 and S2 for switching
point S2.
To teach in a switching point, proceed as follows:
- The position detection damping element must be placed at the relevant position, i.e. the switching point
that you wish to teach in.
2
This product may not be used in applications where personal safety
depends on the function of the device.
This product is not a safety component as described in EU Machinery Directive.
Only the current output or the voltage output may be used. The unused output must remain
load free.
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
• Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://
Release date: 2012-05-30 16:55 Date of issue: 2012-05-30 191137_eng.xml