Inductive positioning system PMI360-F110-IU-V1
Technical data
General specifications
Switching element function analog, current or voltage output
Object distance max. 6 mm
Measurement range 0 ... 360 mm
Nominal ratings
Model Number
PMI360-F110-IU-V1
Features
• Analog output 0 V ... 10 V/4 mA ...
20 mA
• Measuring range 0 ... 360 mm
Operating voltage U
Reverse polarity protection reverse polarity protected
Linearity error ± 0.4 mm
Repeat accuracy R ± 0.2 mm
Resolution 360 µm
Temperature drift ± 0.5 mm (-25 °C ... 70 °C)
No-load supply current I
Operating voltage indicator LED green
Functional safety related parameters
MTTFd 210 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Analog output
Output type 1 current output: 4 ... 20 mA
Load resistor current output: ≤ 400 Ω
Short-circuit protection voltage output: pulsing
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type 4-pin, M12 x 1 connector
Housing length L 400 mm
Degree of protection IP65
Material
Housing PA 6 / AL
Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Note The data relating to accuracy only apply to a distance to the
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
18 ... 30 V DC
≤ 40 mA
1 voltage output: 0 ... 10 V
voltage output: ≥ 1000 Ω
object to be detected of 1 ... 6 mm.
IEC 60947-5-2:2007
Dimensions
0V/4mA
Electrical Connection
IU
I
Core colours in accordance with
EN 60947-5-2.
30.5
8 ± 0.15
L17
10V/20mA
1
(BN)
4
(BK)
I
2
(WH)
U
3
(BU)
+ UB
4 - 20 mA
0 - 10 V
- UB
41 ± 0.15
Release date: 2012-05-14 13:31 Date of issue: 2016-05-03 191141_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Inductive positioning system PMI360-F110-IU-V1
Pinout
1
2
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
(brown)
(white)
(blue)
(black)
4
3
Accessories
BT-F110-G
Damping element for F110 housing sensors; front screw holes
BT-F110-W
Damping element for F110 housing sensors; lateral screw holes
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
MH-F110
Mounting bracket for mounting F110 series sensors
Instruction manual
• Security advice
Warn ing
• Sensor Properties
The inductive positioning system F110 provides both, a current and voltage signal at the outputs, which is
proportional to the position of the attenuating element.
Output signals: 4 mA ... 20 mA and 0 V ... 10 V
• Attenuating element
The inductive position encoding system F110 is optimally
adjusted to the geometry of the attenuating elements we offer
(see accessories, below).
Note
• Installation and operation
Notes on installation
- A flush installation is possible.
- Fixation and installation of the positioning system F110 is carried out by
the use of t-slides. This provides a flexible adaptation to the field situation.
- The distance between the measuring field (bordered area at the front of
the sensor) and the fixing base or fixing element of the attenuating element must at least be 6 mm.
This product must not be used in applications, where safety of persons
depend on the correct device function.
This product is not a safety device according to EC machinery directive.
13
≥ 41
When using your own attenuating elements, you
must ensure that the active surface of the attenuating element has a width of exactly 13 mm and
overlaps the entire sensor width (41 mm).
A different width has a direct impact on the achievable resolution and accuracy of the system.
Spacing between sensor and attenuating element is from 0 ... 6 mm.
Sensing accuracy is guaranteed between 1 ... 6 mm..
screw head
≥ 4
6
• Notes on operation
The sensor accuracy can be guaranteed, when the spacing between attenuating element and sensor is
within an interval of 1 ... 6 mm.
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
6
2
Release date: 2012-05-14 13:31 Date of issue: 2016-05-03 191141_eng.xml