Pepperl Fuchs PMI360DV-F130-IU2E0-V15 Data Sheet

Ind. angular measuring system PMI360DV-F130-IU2E0-V15
Technical data
General specifications
Model Number
PMI360DV-F130-IU2E0-V15
Features
• Analog output, load-dependent voltage or current
• 2 configurable switching frames
• Parameterisable measuring range
Measurement range max. 360°
Nominal ratings
Operating voltage U Reverse polarity protection reverse polarity protected Repeat accuracy R ± 0.25 ° Resolution 0.2 ° Temperature drift 0.02 ° / °C (-25 °C ... 70 °C) No-load supply current I Time delay before availability t
Indicators/operating means
LED yellow 1 switching state, Switching output 1 LED yellow 2 switching state, Switching output 2 LED PWR/ERR Status display LED, green/red (Power on / missing actuator
LED U/I Activator within measuring range
Switching output
Output type 2 switch outputs NPN, NO , reverse polarity protected ,
Operating current I Switching hysteresis 1 ° Voltage drop 3 V Short-circuit protection pulsing
Analog output
Output type current output or voltage output (load dependend)
Linearity error ± 0.6 ° , (with original actuator)
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type 5-pin, M12 x 1 connector Degree of protection IP67 Material
Housing PBT Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Mass 180 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
B
0
v
L
min. 90°
100 min
18 ... 30 V DC
45 mA 1 s
/ keylock)
short-circuit protected , programmable 100 mA
4 ... 20 mA (R 0 ... 10 V (R
IEC 60947-5-2:2007
-1
< 400 Ω)
L
> 3.3 kΩ)
L
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated
36 V
Release date: 2015-02-09 15:53 Date of issue: 2015-02-09 225670_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ind. angular measuring system PMI360DV-F130-IU2E0-V15
Dimensions
ø 10
26
ø 5.2
110 10.3 ± 0.3
76.5
Electrical Connection
30
ø 41.5
40
1
2
4
5
3
L+
Q1
Q2
I/U
L-
Accessories
BT-F130-A
Actuator for F130 series
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
V15-W-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Using a different actuating element
You can use a different actuator instead of the BT-F130-A actuator provided, which must be positioned cen­trally in the sensor opening. When using a different actuating element, the element must fulfill all requirements relating to the material, dimensions and distance to the sensitive surface on the sensors (see table). Failing to fulfill all of these requirements may reduce the accuracy/resolution of the sensor or even cause the sensor to stop functioning.
Release date: 2015-02-09 15:53 Date of issue: 2015-02-09 225670_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2