Pepperl+Fuchs PCV-USB-RS485 Quick Start Manual

Page 1
FACTORY AUTOMATION
Quick Start Guide
PCV-USB-RS485-Converter
Page 2
DOCT-2116B 2018-06
Page 3
PCV-USB-RS485-Converter Set
Warning
Attention
Note
Warning
2 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5 Connecting the reading head PCV80-F200-R4-... . . .9
Used symbols
This symbol warns the user of potential danger. Nonobservance may lead to personal injury or death and/ or damage to property.
This symbol warns the user of potential device failure. Nonobservance may lead to the complete failure of the device or other devices connected.
This symbol calls attention to important notes.
Security advice
2018-06 DOCT-2116B
This product must not be used in applications, where safety of persons depend on the correct device function. This product is not a safety device according to EC machinery directive.
1
Page 4
PCV-USB-RS485-Converter Set
ISO9001
Notes
These operating instructions refer to proper and intended use of this product. They must be read and observed by all persons making use of this product. This product is only able to fulfill the tasks for which it is designed if it is used in accordance with specifications of Pepperl+Fuchs.
The warrantee offered by Pepperl+Fuchs for this product is null and void if the product is not used in accordance with the specifications of Pepperl+Fuchs.
Changes to the devices or components and the use of defective or incomplete devices or components are not permitted. Repairs to devices or components may only be performed by Pepperl+Fuchs or authorized work shops. These work shops are responsible for acquiring the latest technical information about Pepperl+Fuchs devices and components. Repair tasks made on the product that are not performed by Pepperl+Fuchs are not subject to influence on the part of Pepperl+Fuchs. Our liability is thus limited to repair tasks that are performed by Pepperl+Fuchs.
The preceding information does not change information regarding warrantee and liability in the terms and conditions of sale and delivery of Pepperl+Fuchs.
This device contains sub-assemblies that are electrostatically sensitive. Only qualified specialists may open the device to perform maintenance and repair tasks. Touching the components without protection involves the risk of dangerous electrostatic discharge, and must be avoided. Destruction of basic components caused by an electrostatic discharge voids the warrantee!
Subject to technical modifications.
Pepperl+Fuchs GmbH in D-68301 Mannheim maintains a quality assurance system certified according to ISO 9001.
2
2018-06 DOCT-2116B
Page 5
1Description
This Quick Start Guide is not a complete function description of the interface converter PCV-USB-RS485-Converter. The intention of this document is to give you a step by step instruction for commisioning of this interface under MS-Windows XP.
2 Intended Use
The PCV-USB-RS485-Converter Set is an interface converter which enables the configuration of devices with RS485 interface or RS422 interface over a standard USB computer interface.
3 Scope of delivery
In the shipment you will find:
PCV-USB-RS485-Converter Set
Description
Interface converter
Power supply 110V/230V with cordset
USB cable 0.8 m long
CD with device driver and instruction manual
4 Configuration
For correct usage of the interface converter PCV-USB-RS485-Converter, at your personnel computer proceed as follows:
1. Set the position of the DIP-switches at the interface as shown below:
Set the position of the DIP-switches at the interface as shown below for all interface converter from serial number A000762: Switch 1: ON Switch 2: OFF Switch 3: OFF Switch 4: OFF
PCV-USB-RS485-Converter
Switch 1: OFF Switch 2: OFF Switch 3: ON Switch 4: ON
DOCT-2116A 2018-06
3
Page 6
PCV-USB-RS485-Converter Set
Configuration
Do not plug in the interface converter to your PC just yet!
2. First, install the software from the enclosed CD. Restarting the system is not required.
4
DOCT-2116A 2018-06
Page 7
PCV-USB-RS485-Converter Set
3. Right click the My Computer icon and select the submenu "Properties" .
4. Go now to the submenu "Hardware".
Configuration
5. Then select the submenu "Device manager".
DOCT-2116A 2018-06
5
Page 8
6. Under "Device manager", go to "Ports (COM& LPT)".
Click at the + symbol in front of "Ports (COM& LPT)" to sho all presently available ports.
PCV-USB-RS485-Converter Set
Configuration
7. Now plug the adapter into the computer using the USB cord. The red LED indicates the interface converters operation state.
6
DOCT-2116A 2018-06
Page 9
PCV-USB-RS485-Converter Set
8. Watch the ports listed. After a few seconds at the end of the list, a new entry will appears "USB Serial Port (COMxx)". In the screenshot nearby it is that USB Serial Port (COM4)).
9. Right click the new entry and select "Properties".
Configuration
10. With the properties tab of that USB Serial Port shown, click on the submenu "Port Settings". Click on the sub menu "Advanced".
DOCT-2116A 2018-06
7
Page 10
PCV-USB-RS485-Converter Set
11. In that "Advance settings for COMxx" menue, set the value for "receiving (bytes)" as well as "transmit (bytes)" to the minimum (64).
Configuration
12. Set the "Latency Time" to the minimum (1 ms).
13. Confirm the configuration with a click at "OK".
The necessary settings for the parameterization of type PCV...-R4-... photoelectric reading heads are done, now.
8
DOCT-2116A 2018-06
Page 11
PCV-USB-RS485-Converter Set
Note
Connecting the reading head PCV80-F200-R4-...
5 Connecting the reading head PCV80-F200-R4-...
If applicable, install the interface converter software in your PC system before connecting the components. Follow the instructions in the quick start guide to the interface converter when doing so.
Establish the electrical connections as shown and plug the power supply into a socket.
Once the USB connection between the PC system and interface converter is established, the red PWR LED on the interface converter lights up.
Once the electrical connection to the Data Matrix reading head is established and the plug-in power supply is supplying the power, the red ring of light on the reading head lights up.
Make sure that the position of the DIP switches corresponds to the required settings.
DOCT-2116A 2018-06
9
Page 12
PCV-USB-RS485-Converter Set
Connecting the reading head PCV80-F200-R4-...
10
DOCT-2116A 2018-06
Page 13
Subject to modifications Copyright PEPPERL+FUCHS • Printed in Germany
www.pepperl-fuchs.com
Worldwide Headquarters
Pepperl+Fuchs GmbH 68307 Mannheim · Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com
USA Headquarters
Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com
Asia Pacific Headquarters
Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com
FACTORY AUTOMATION – SENSING YOUR NEEDS
DOCT-2116B
2018-06
Loading...