Pepperl Fuchs PCV100-F200-R4-V15-LS221 Data Sheet

Optical reading head PCV100-F200-R4-V15-LS221
Technical data
General specifications
Passage speed v 8 m/s Measuring range max. 524 m Light type Integrated LED lightning (red) Read distance 100 mm Depth of focus ± 20 mm Reading field 50 mm x 30 mm Ambient light limit 100000 Lux Resolution ± 1 mm
Nominal ratings
Camera
Type CMOS , Global shutter
Processor
Clock pulse frequency 600 MHz Speed of computation 4800 MIPS
Functional safety related parameters
MTTFd 108 a Mission Time (TM) 54 a Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED indicator 7 LEDs (communication, alignment aid, status information)
Model Number
PCV100-F200-R4-V15-LS221
Read head for incident light positioning system
Features
• RS 485 interface
• Non-contact positioning on Data Matrix code tape
• Mechanically rugged: no wearing parts, long operating life, mainte­nance-free
• High resolution and precise posi­tioning, especially for facilities with curves and switch points as well as inclines and declines.
• Travel ranges up to 524 m
Diagrams
Coordinates
Y
Z
X
Electrical specifications
Operating voltage U No-load supply current I Power consumption P
Interface
Interface type RS 485 interface Data output code binary code Protocol WCS...B-LS221 Transfer rate 62500 Bit/s Termination Switchable terminal resistor Query cycle time 10 ms
Input
Input type 1 funtion input
Input impedance 27 k
Output
Output type 1 switch output PNP , programmable , short-circuit protected Switching voltage Operating voltage Switching current 150 mA each output
Standard conformity
Emitted interference EN 61000-6-4:2007+A1:2011 Noise immunity EN 61000-6-2:2005 Shock resistance EN 60068-2-27:2009 Vibration resistance EN 60068-2-6:2008
Ambient conditions
Operating temperature 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -20 ... 85 °C (-4 ... 185 °F) Relative humidity 90 % , noncondensing
Mechanical specifications
Connection type 5-pin, M12 x 1 connector Housing width 70 mm Housing height 70 mm Degree of protection IP67 Material
Housing PC/ABS
Mass approx. 160 g
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source,
CCC approval CCC approval / marking not required for products rated ≤36
B
0
0
15 ... 30 V DC , PELV max. 200 mA 3 W
0-level: -U 1-level: +8 V ... +U
(noncondensing; prevent icing on the lens!)
Type 1 enclosure
V
or unwired
B
, programmable
B
Release date: 2017-03-24 13:05 Date of issue: 2017-03-24 254045_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Optical reading head PCV100-F200-R4-V15-LS221
Dimensions
9
Additional Information
4 x M6
51
ø 25
22
4
5
8
3
6
2
1
7
70
80
1
2
38.5
70 14.5
M12 x 1
12
ADJUST
CONFIG
COM
LED 1 2 3 4 5 6 7
1
2
OUT1
ADJ Y
PWR / ADJ
ERR / NO CODE
ADJ Z
INTERNAL
DIAGNOSTIC
Electrical Connection
Pinout
Accessories
V15-G-ABG-PG9
1
2
3
4
5
+ U
B
Data +
- U
B
Data -
I/O
1
5
2
4
3
Female connector, M12, 5-pin, shielded, field attachable
V15-G-ABG-PG9-FE
Female connector, M12, 5-pin, shielded, field attachable
PCV-SC12
Grounding clip for PCV system
PCV-LM25
Marker head for 25 mm code tape
PCV-MB1
Mounting bracket for PCV* read head
PCV-AG100
Alignment guide for PCV100-* read head
Vision Configurator
Operating software for camera-based sensors
PCV-KBL-V19-STR-RS485
Cable unit with power supply for USB / RS­485 interface converter
PCV-USB-RS485-Converter Set
USB to RS 485 interface converter
General
The PCV… reading head is part of the positioning system in the method for measurement by Pepperl+Fuchs. It consists of a camera module and an integrated illumination unit among other things. The reading head detects po­sition marks, which are put on an adhesive code band in the form of Data Matrix code. The mounting of the code band is as a rule stationary on a firm part of the plant (elevator shaft, overhead conveyor mounting rails…); that of the reading head is parallel on the moving "vehicle" (elevator car, overhead conveyor chassis…).
Mounting and commissioning
Mount the reading head such that its optical surface captures the optimal read distance to the code band (see Tech-
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2017-03-24 13:05 Date of issue: 2017-03-24 254045_eng.xml