High temperature identification system OIT500-F113-B12-CB
Function
The OIT500-* stationary read device is an optical identification system that works using industrial vision methods and is used in automated manufacturing processes. The ambient conditions in automobile construction in particular, for example the cyclical temperature changes,
often make the use of read-only tags with electronic components difficult if not impossible.
For the OIT high-temperature identification system, read-only tags of solid metal plates with a
perforated matrix are used, which are designed for use at temperatures of up to 500 °C and
suitable for high mechanical stress.
Simple installation and commissioning without complicated, time-consuming Teach-In processes enable rapid entry. Pluggable connections for the rapid exchange of devices and a controller with simple command set via the Ethernet interface guarantee simple operation. A
scratch-resistant, replaceable quartz glass panel and sturdy metal housing make the OIT500* a robust, efficient identification system.
Indicating / Operating means
1 Grounding screw
2 Power supply
3 Network
4 Trigger
5 external illumination
4-pin M12 socket
(external illumination)
1
1
2
4
4
Pin Signal
1 24 V power supply
2 Laser control
3 Ground
4 Illumination control
2
3
3
Model Number
OIT500-F113-B12-CB
Optical high temperature identification
system, 200 to 450 mm
Features
• High-temperature code carrier up to
500 °C (932 °F)
• Sturdy and compact design
• Integrated illumination
• High operating range
• Large sensing range
• High depth of focus
1
2
Electrical connection
8-pin Network connection
(LAN)
8
7
6
5
4
3
2
1
Pin Signal
1 Transmit data (+)
2 Transmit data (-)
3 Receive data (+)
4 not assigned
5 not assigned
6 Receive data (-)
7 not assigned
8 not assigned
3
4
5
Release date: 2016-06-14 15:45 Date of issue: 2016-06-14 194232_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
8-pin Harting connection
(Process)
1
Pin Signal
1 Composite error output
2 External ground
3 Mode bit 1
4 Mode bit 0
5 24 V external power supply
6 24 V device power supply
7 Trigger release input
8 Device ground
8
23
7
654
Technical data
General specifications
Light source Integrated LED lightning
Light type infrared
4-pin M12 socket
(Trigger)
1
4
Pin Signal
1 24 V power supply
2 not assigned
3 Ground
4 Trigger signal
2
3
1

OIT500-F113-B12-CBHigh temperature identification system
Symbologies Hole matrix
Read distance 200 ... 450 mm
Depth of focus ± 50 mm
Reading field 330 mm x 250 mm at max. read distance
Evaluation frequency 5 Hz
Target velocity triggered ≤ 0.5 m/s
Functional safety related parameters
MTTFd 51 a
Mission Time (TM) 10 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green: supply
Function indicator Yellow LED: trigger
Electrical specifications
Operating voltage UB24 V DC ± 15% , PELV
Operating current I
Interface
Physical Ethernet
Protocol TCP/ IP
Transfer rate 100 MBit/s
Input
Input voltage to be applied externally 24 V ± 15% PELV
Number/Type 1 trigger input 2 control unit inputs , optically decoupled
Input current approx. 1 mA at 24 V DC
Output
Number/Type 1 electronic output, PNP, optically decoupled
Switching voltage to be applied externally 24 V ± 15 % PELV
Switching current 100 mA each output
Ambient conditions
Ambient temperature 0 ... 45 °C (32 ... 113 °F)
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP64
Connection 8-pin Harting HAN
Material
Housing diecast aluminum powder coated
Mass approx. 4000 g
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/EC EN 61326-1 , EN 61000-6-4
Standard conformity
Noise immunity EN 61326-1
Emitted interference EN 61000-6-4:2007/A1:2011
Degree of protection EN 60529
Data format: decimal
Data capacity: 6 (numerical)
Orientation: omnidirectional
LED green: ready
Yellow LED: code read
Red LED: pre-fault
Red LED: group error
250 mA without output drivers
B
RJ-45
2 x 5-pin M12 socket
Supplied ferrite sleeve for suppression of the Ethernet cable
Accessories
OIC-C10V2A-CB1
Code carrier for optical high-temperature
identification system, stainless steel
V8HAN-G-10M-PVC-ABG
Female cordset, Harting, 8-pin, shielded,
PVC cable
V45-GP-10M-PUR-ABG-V45-G
Connecting cable, RJ-45 to RJ-45, PUR
cable
V45-GP
Field-attachable "Push-Pull" connector
V45-G
Field-attachable male connector
V1S-G-10M-PVC
Cable connector, M12, 4-pin, PVC cable
V8HAN-G
Female connector, Harting, 8-pin, field attachable
OITControl
Software for OIT high temperature identification system
OIZ-FG500
Replacement glass for series OIT300,
OIT500 and OIT1500
Other suitable accessories can be found at
Approvals and certificates
EAC conformity TR CU 020/2011
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2016-06-14 15:45 Date of issue: 2016-06-14 194232_eng.xml