High temperature identification system OIT1500-F113-B12-CB
Function
The stationary scanner OIT1500-F113-B12-CB is an optical identification system using the
methods of industrial image processing, which finds application in automated manufacturing
processes. In particular with bodyshell work, there are harsh ambient conditions, which complicate or render impossible the application of code carriers with electronic components due to
cyclical changes in temperature, for example.
For this reason, the high-temperature identification system OIT is fitted with code carriers with
massive metal plates provided with a perforated matrix, which can withstand temperatures up
to 500 °C and high mechanical loads.
Simple installation as well as commissioning without complicated and long-winded TEACH-IN
enable fast application. Plug-in connections for fast exchange of devices and the control with
simple command sets through an Ethernet interface ensure very easy operation. A scratch
resistant quartz glass pane, which can be replaced, if and when required, as well as the stable
metal housing turn the OIT1500-F113-B12-CB into a robust and powerful identification system.
Indicating / Operating means
1 Grounding screw
2 Power supply
3 Network
Model Number
OIT1500-F113-B12-CB
Optical high temperature identification
system, 750 ... 1700 mm
Features
• High-temperature code carrier up to
500 °C (932 °F)
• Sturdy and compact design
• High operating range
• High depth of focus
• External illumination included in delivery
1
2
Electrical connection
8-pin Network connection
(LAN)
8
7
6
5
4
3
2
1
Pin Signal
1 Transmit data (+)
2 Transmit data (-)
3 Receive data (+)
4 not assigned
5 not assigned
6 Receive data (-)
7 not assigned
8 not assigned
3
4
5
4 Trigger
5 external illumination
4-pin M12 socket
(external illumination)
1
1
2
4
4
Pin Signal
1 24 V power supply
2 Laser control
3 Ground
4 Illumination control
2
3
3
Release date: 2016-06-14 15:45 Date of issue: 2016-06-14 194233_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
8-pin Harting connection
(Process)
1
Pin Signal
1 Composite error output
2 External ground
3 Mode bit 1
4 Mode bit 0
5 24 V external power supply
6 24 V device power supply
7 Trigger release input
8 Device ground
8
23
7
654
Technical data
General specifications
Light source External lighting
4-pin M12 socket
(Trigger)
1
4
Pin Signal
1 24 V power supply
2 not assigned
3 Ground
4 Trigger signal
2
3
1

OIT1500-F113-B12-CBHigh temperature identification system
Light type infrared
Symbologies Hole matrix
Read distance adjustable 750 ... 1700 mm
Depth of focus ± 50 mm
Reading field 320 mm x 235 mm at max. read distance
Evaluation frequency 5 Hz
Target velocity triggered ≤ 0.5 m/s
Functional safety related parameters
MTTFd 51 a
Mission Time (TM) 10 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green: supply
Function indicator Yellow LED: trigger
Electrical specifications
Operating voltage UB24 V DC ± 15% , PELV
Operating current I
Interface
Physical Ethernet
Protocol TCP/ IP
Transfer rate 100 MBit/s
Input
Input voltage to be applied externally 24 V ± 15% PELV
Number/Type 1 trigger input 2 control unit inputs , optically decoupled
Input current approx. 1 mA at 24 V DC
Output
Number/Type 1 electronic output, PNP, optically decoupled
Switching voltage to be applied externally 24 V ± 15 % PELV
Switching current 100 mA each output
Ambient conditions
Ambient temperature 0 ... 45 °C (32 ... 113 °F)
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP64
Connection 8-pin Harting HAN
Material
Housing diecast aluminum powder coated
Mass approx. 4000 g
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/EC EN 61326-1 , EN 61000-6-4
Standard conformity
Noise immunity EN 61326-1
Emitted interference EN 61000-6-4:2007/A1:2011
Degree of protection EN 60529
Data format: decimal
Data capacity: 6 (numerical)
Orientation: omnidirectional
LED green: ready
Yellow LED: code read
Red LED: pre-fault
Red LED: group error
250 mA without output drivers
B
RJ-45
2 x 5-pin M12 socket
Supplied ferrite sleeve for suppression of the Ethernet cable
Accessories
V45-GP-10M-PUR-ABG-V45-G
Connecting cable, RJ-45 to RJ-45, PUR
cable
OIC-C10ST-CB1
Code support for visual high-temperature
identification system
OIC-C10V2A-CB1
Code carrier for optical high-temperature
identification system, stainless steel
V8HAN-G-10M-PVC-ABG
Female cordset, Harting, 8-pin, shielded,
PVC cable
V45-G
Field-attachable male connector
V45-GP
Field-attachable "Push-Pull" connector
V8HAN-G
Female connector, Harting, 8-pin, field attachable
OITControl
Software for OIT high temperature identification system
OIZ-FG500
Replacement glass for series OIT300,
OIT500 and OIT1500
Other suitable accessories can be found at
Approvals and certificates
EAC conformity TR CU 020/2011
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2016-06-14 15:45 Date of issue: 2016-06-14 194233_eng.xml