• Miniature design with versatile
mounting options
• DuraBeam Laser Sensors - durable
and employable like an LED
• IO-link interface for service and
process data
• Various frequencies for avoiding
mutual interference (cross-talk
immunity)
• Extended temperature range
-40°C ... 60°C
• High degree of protection IP69K
10.2
24.1
M18 x 1
Receiver
Transmitter
Electrical connection emitter
Electrical connection receiver
26.7
7.4
7.5
M8 x 1
1
L+
2
n.c.
4
C/Q
3
L-
1
4
2
3
L+
C/Q
Q
L-
Receiver
15
ø 3.3 x 2
Transmitter
22.1
36.5
Product information
The R103 series miniature optical sensors
are the first devices of their kind to offer an
end-to-end solution in a small single standard
design — from thru-beam sensor through to a
distance measurement device. As a result of
this design, the sensors are able to perform
practically all standard automation tasks.
The entire series enables sensors to
communicate via IO-Link.
The DuraBeam laser sensors are durable and
can be used in the same way as a standard
sensor.
The use of Multi Pixel Technology gives the
standard sensors a high level of flexibility and
enables them to adapt more effectively to
their operating environment.
Release date: 2018-06-08 14:07 Date of issue: 2018-09-19 284462_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Effective detection range 0 ... 20 m
Threshold detection range 30 m
Light source laser diode
Light type modulated visible red light
Laser nominal ratings
Note LASER LIGHT , DO NOT STARE INTO BEAM
Laser class 1
Wave length 680 nm
Beam divergence > 5 mrad ; d63 < 2 mm in the range of 250 mm ... 750 mm
Pulse length 1.6 µs
Repetition rate max. 17.6 kHz
max. pulse energy 9.6 nJ
Diameter of the light spot approx. 50 mm at a distance of 20 m
Angle of divergence approx. 0.3 °
Ambient light limit EN 60947-5-2 : 30000 Lux
Functional safety related parameters
MTTFd 440 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green:
Function indicator Yellow LED:
Control elements Receiver: light/dark switch
Control elements Receiver: sensitivity adjustment
Parameterization indicator IO link communication: green LED goes out briefly (1 Hz)
Electrical specifications
Operating voltage UB10 ... 30 V DC
Ripple max. 10 %
No-load supply current I
Protection class III
Interface
Interface type IO-Link ( via C/Q = pin 4 )
Transfer rate COM 2 (38.4 kBaud)
IO-Link Revision 1.1
Min. cycle time 2.3 ms
Process data witdh Emitter:
SIO mode support yes
Device ID Emitter: 0x110404 (1115140)
Compatible master port type A
Input
Test input emitter deactivation at +U
Output
Switching type The switching type of the sensor is adjustable. The default
Signal output 2 push-pull (4 in 1)outputs, short-circuit protected, reverse
Switching voltage max. 30 V DC
Switching current max. 100 mA , resistive load
Usage category DC-12 and DC-13
Voltage drop Ud≤ 1.5 V DC
Switching frequency f1250 Hz
Response time 0.4 ms
Conformity
Communication interface IEC 61131-9
Product standard EN 60947-5-2
Laser safety EN 60825-1:2014
Release date: 2018-06-08 14:07 Date of issue: 2018-09-19 284462_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Release date: 2018-06-08 14:07 Date of issue: 2018-09-19 284462_eng.xml
Page 5
Laser thru-beam sensor
OBE20M-R103-S2EP-IO-V31-L
To unlock the adjustment functions turn the sensing range adjuster / sensitivity adjuster for more than 180 degrees.
Sensing Range/ Sensitivity
Turn sensing range / sensitivity adjuster clockwise to increase sensing range / sensitivity.
Turn sensing range / sensitivity adjuster counter clockwise to decrease sensing range / sensitivity.
If the end of the adjustment range is reached, the signal indicator starts flashing with 8 Hz.
Light-on / Dark-on Configuration
Press the light-on / dark-on changeover switch for more than 1 second (less than 4 seconds). The light-on / dark-on mode changes and the operating indicators are activated accordingly.
If you press the light-on / dark-on changeover switch for more than 4 seconds, the light-on /dark-on mode changes back to the
original setting. On release of the light-on / dark-on changeover switch the current state is activated.
Restore Factory Settings
Press the light-on / dark-on changeover switch for more than 10 seconds (less than 30 seconds) until all LEDs turn off. On release
of the light-on / dark-on changeover switch the signal indicator turns on. After 5 seconds the sensor resumes operation with
factory default settings.
After 5 minutes of inactivity the sensing range / sensitivity adjustment is locked. In order to reactivate the sensing range / sensitivity adjustment, turn the sensing range / sensitivity adjuster for more than 180 degrees.
Release date: 2018-06-08 14:07 Date of issue: 2018-09-19 284462_eng.xml