• Miniature design with versatile
mounting options
• IO-link interface for service and
process data
• Various frequencies for avoiding
mutual interference (cross-talk
immunity)
• Extended temperature range
-40°C ... 60°C
• High degree of protection IP69K
Product information
The R103 series miniature optical sensors
are the first devices of their kind to offer an
end-to-end solution in a small single standard
design — from thru-beam sensor through to a
distance measurement device. As a result of
this design, the sensors are able to perform
practically all standard automation tasks.
The entire series enables sensors to
communicate via IO-Link.
The DuraBeam laser sensors are durable and
can be used in the same way as a standard
sensor.
The use of Multi Pixel Technology gives the
standard sensors a high level of flexibility and
enables them to adapt more effectively to
their operating environment.
10.2
24.1
M18 x 1
Receiver
Transmitter
Electrical connection emitter
Electrical connection receiver
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
24
13
2 WH
3 BU
4 BK
26.7
7.4
7.5
M8 x 1
1
L+
2
n.c.
4
C/Q
3
L-
1
4
2
3
L+
C/Q
Q
L-
(brown)
(white)
(blue)
(black)
Receiver
15
ø 3.3 x 2
Transmitter
22.1
36.5
Release date: 2017-04-04 13:20 Date of issue: 2018-09-19 284456_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Effective detection range 0 ... 10 m
Threshold detection range 12.5 m
Light source LED
Light type modulated visible red light
LED risk group labelling exempt group
Diameter of the light spot approx. 65 mm at a distance of 1 m
Angle of divergence 3.7 °
Ambient light limit EN 60947-5-2 : 30000 Lux
Functional safety related parameters
MTTFd 462 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green:
Function indicator Yellow LED:
Control elements Receiver: light/dark switch
Control elements Receiver: sensitivity adjustment
Parameterization indicator IO link communication: green LED goes out briefly (1 Hz)
Electrical specifications
Operating voltage UB10 ... 30 V DC
Ripple max. 10 %
No-load supply current I
Protection class III
Interface
Interface type IO-Link ( via C/Q = pin 4 )
Transfer rate COM 2 (38.4 kBaud)
IO-Link Revision 1.1
Min. cycle time 2.3 ms
Process data witdh Emitter:
SIO mode support yes
Device ID Emitter: 0x110403 (1115139) Receiver: 0x110303 (1114883)
Compatible master port type A
Input
Test input emitter deactivation at +U
Output
Switching type The switching type of the sensor is adjustable. The default
Signal output 2 push-pull (4 in 1)outputs, short-circuit protected, reverse
Switching voltage max. 30 V DC
Switching current max. 100 mA , resistive load
Usage category DC-12 and DC-13
Voltage drop U
Switching frequency f1000 Hz
Response time 0.5 ms
Ambient conditions
Ambient temperature -40 ... 60 °C (-40 ... 140 °F)
) 20 a
M
0
d
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Release date: 2017-04-04 13:20 Date of issue: 2018-09-19 284456_eng.xml
Thru-beam sensor
OBE10M-R103-S2EP-IO-V31
Turn sensing range / sensitivity adjuster counter clockwise to decrease sensing range / sensitivity.
If the end of the adjustment range is reached, the signal indicator starts flashing with 8 Hz.
Light-on / Dark-on Configuration
Press the light-on / dark-on changeover switch for more than 1 second (less than 4 seconds). The light-on / dark-on mode changes and the operating indicators are activated accordingly.
If you press the light-on / dark-on changeover switch for more than 4 seconds, the light-on /dark-on mode changes back to the
original setting. On release of the light-on / dark-on changeover switch the current state is activated.
Restore Factory Settings
Press the light-on / dark-on changeover switch for more than 10 seconds (less than 30 seconds) until all LEDs turn off. On release
of the light-on / dark-on changeover switch the signal indicator turns on. After 5 seconds the sensor resumes operation with
factory default settings.
After 5 minutes of inactivity the sensing range / sensitivity adjustment is locked. In order to reactivate the sensing range / sensitivity adjustment, turn the sensing range / sensitivity adjuster for more than 180 degrees.
Release date: 2017-04-04 13:20 Date of issue: 2018-09-19 284456_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.