PEPPERL+FUCHS OBD1100-R100-IR2 Datasheet

Diffuse mode sensor
Dimensions
OBD1100-R100-2EP-IO-IR
21.5
8.7
5.5
14.5
11
M3 (2x) 3.2
Model Number
OBD1100-R100-2EP-IO-IR
Diffuse mode sensor
with fixed cable
Features
• Miniature design with versatile mounting options
• Extended temperature range
-40°C ... 60°C
• High degree of protection IP69K
• IO-link interface for service and process data
• Infrared light design
Product information
37.1
3.3
2000 +50
100
6
4.2
Electrical connection
BN
L+
BK
C/Q
WH
BU
Q
L-
Indicators/operating means
2
1
3
4
5
25.4
Receiver
Emitter
19.95
Receiver
Emitter
14.2
15.9
10
7.4
ø 3.2
1 Light-on/Dark-on changeover switch
2 Sensitivity adjuster
3 Operating indicator / dark on
4 Signal indicator
5 Operating indicator / light on
The miniature optical sensors are the first devices of their kind to offer an end-to- end solution in a small single standard design from thru-beam sensor through to a distance measurement device. As a result of this design, the sensors are able to perform practically all standard automation tasks.
The DuraBeam laser sensors are durable and can be used in the same way as a standard sensor.
The use of Multi Pixel Technology gives the standard sensors a high level of flex ibility and enables them to adapt more effectively to their operating environment.
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001 Singapore: +65 6779 9091
Germany: +49 621 776 1111Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
1
Diffuse mode sensor
OBD1100-R100-2EP-IO-IR
Technical data
General specifications
Detection range 2 ... 1100 mm Detection range min. 10 ... 60 mm Adjustment range 60 ... 1100 mm Reference target standard white, 100 mm x 100 mm Light source LED Light type modulated infrared light 850 nm LED risk group labelling exempt group Diameter of the light spot approx. 100 mm at a distance of 1000 mm Angle of divergence 5.4 ° Ambient light limit EN 60947-5-2
Functional safety related parameters
MTTFd 724 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green:
Function indicator LED yellow:
Control elements Light-on/dark-on changeover switch Control elements Sensing range adjuster
Electrical specifications
Operating voltage UB10 ... 30 V DC Ripple max. 10 % No-load supply current I Protection class III
Interface
Interface type IO-Link ( via C/Q = BK ) Transfer rate COM 2 (38.4 kBaud) IO-Link Revision 1.1 Min. cycle time 2.3 ms Process data witdh Process data input 1 Bit
SIO mode support yes Device ID 0x110101 (1114369) Compatible master port type A
Output
Switching type The switching type of the sensor is adjustable. The default
Signal output 2 push-pull (4 in 1)outputs, short-circuit protected, reverse
Switching voltage max. 30 V DC Switching current max. 100 mA , resistive load Usage category DC-12 and DC-13 Voltage drop U Switching frequency f 1000 Hz Response time 0.5 ms
Conformity
Communication interface IEC 61131-9 Product standard EN 60947-5-2
Ambient conditions
Ambient temperature -40 ... 60 °C (-40 ... 140 °F) , fixed cable
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Housing width 11 mm Housing height 37.1 mm Housing depth 21.5 mm Degree of protection IP67 / IP69 / IP69K Connection 2 m fixed cable Material
Housing PC (Polycarbonate)
Optical face PMMA Mass approx. 10 g Cable length 2 m
constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode
constantly on - object detected constantly off - object not detected
< 25 mA at 24 V supply voltage
0
Process data output 2 Bit
setting is: C/Q - BK: NPN normally open / light-on, PNP normally closed / dark-on, IO-Link /Q - WH: NPN normally closed / dark-on, PNP normally open / light-on
polarity protected, overvoltage protected
1.5 V DC
d
-25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains
Accessories
IO-Link-Master02-USB
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connection
OMH-R10X-01
Mounting bracket
OMH-R10X-02
Mounting bracket
OMH-R10X-04
Mounting bracket
OMH-R10X-10
Mounting bracket
OMH-ML100-03
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
OMH-ML100-031
Mounting aid for round steel ø 10 ... 14 mm or sheet 1 mm ... 5 mm
Other suitable accessories can be found at www.pepperl-fuchs.com
Approvals and certificates
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
2
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001 Singapore: +65 6779 9091
Germany: +49 621 776 1111Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
Release date: 2019-07-15 17:34 Date of issue: 2019-07-15 267075-100432_eng.xml
Diffuse mode sensor
UL approval E87056 , cULus Listed , class 2 power supply , type rating 1
Curves/Diagrams
Characteristic response curve
Offset Y [mm]
15
10
5
0
-5
-10
-15 0 200 400 600 800 1000
X
Y
white 90 %
grey 18 %
Relative received light strength
Excess gain
1000
Distance X [mm]
OBD1100-R100-2EP-IO-IR
100
10
1
0 200 400 600 800 1000 1200
X
white 90 %
Detection ranges
Object colour
white 90%
grey
18%
black
6%
0 200 400 600 800 1000 1200
Detection range [mm]
X
Distance X [mm]
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001 Singapore: +65 6779 9091
Germany: +49 621 776 1111Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
3
Diffuse mode sensor
Functions and Operation
OBD1100-R100-2EP-IO-IR
1 - Light-on / dark-on changeover switch
2 - Sensing range / sensitivity adjuster
3 - Operating indicator / dark on
4 - Signal indicator
5 - Operating indicator / light on
R100
5
1
4
2
LD
3
To unlock the adjustment functions turn the sensing range /sensitivity adjuster for more than 180 degrees.
Sensing Range / Sensitivity
Turn sensing range / sensitivity adjuster clockwise to increase sensing range / sensitivity.
Turn sensing range / sensitivity adjuster counter clockwise to decrease sensing range / sensitivity.
If the end of the adjustment range is reached, the signal indicator starts flashing with 8 Hz.
Light-on / Dark-on Configuration
Press the light-on / dark-on changeover switch for more than 1 second (less than 4 seconds). The light-on / dark-on mode chang­es and the operating indicators are activated accordingly.
If you press the light-on / dark-on changeover switch for more than 4 seconds, the light-on /dark-on mode changes back to the original setting. On release of the light-on / dark-on changeover switch the current state is activated.
Restore Factory Settings
Press the light-on / dark-on changeover switch for more than 10 seconds (less than 30 seconds) until all LEDs turn off. On release of the light-on / dark-on changeover switch the signal indicator turns on. After 5 seconds the sensor resumes operation with factory default settings.
After 5 minutes of inactivity the sensing range / sensitivity adjustment is locked. In order to reactivate the sensing range / sensi­tivity adjustment, turn the sensing range /sensitivity adjuster for more than 180 degrees.
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
4
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001 Singapore: +65 6779 9091
Germany: +49 621 776 1111Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
Release date: 2019-07-15 17:34 Date of issue: 2019-07-15 267075-100432_eng.xml