Inductive sensor NRB12-18GM40-E2-C-V1
Dimensions
M18x1
4
40
45
24
55
Model Number
NRB12-18GM40-E2-C-V1
Features
• 12 mm quasi flush
• Reduction factor = 1
• Weld Immune
• Magnetic field resistant
Connection
1
4
3
L+
L-
Pinout
1
2
4
3
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
(brown)
(white)
(blue)
(black)
Accessories
BF 18
Mounting flange, 18 mm
V1-G
4-pin, M12 female field-attachable connector
V1-W
4-pin, M12 female field-attachable connector
V1-G-OR2M-POC
Female cordset, M12, 4-pin, TPE cable, welding-bead resistant
V1-W-OR2M-POC
Female cordset, M12, 4-pin, TPE cable, welding-bead resistant
Release date: 2013-01-21 12:16 Date of issue: 2013-01-21 201474_eng.xml
Subject to modifications without notice
LED
M12x1
6
Technical Data
General specifications
Switching element function PNP NO
Rated operating distance s
Installation quasi flush
Output polarity switched high
Assured operating distance sa0 ... 9.72 mm
Reduction factor r
Reduction factor rCu 1
Reduction factor r
Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC
Switching frequency f 0 ... 600 Hz
Hysteresis H typ. 3 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop U
Operating current I
Off-state current I
No-load supply current I
Switching state indication Multihole-LED, yellow
Mag. Field strength, AC fields 200 mT
Mag. Field strength, DC fields 200 mT
Functional safety related parameters
MTTFd 1074 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Device connector M12 x 1 , 4-pin
Housing material Brass, PTFE coated
Sensing face Ryton R4
Protection degree IP67
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
Protection class II
Rated insulation voltage U
Design-impulse-voltage withstand U
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Products with a maximum operating voltage of ≤36 V do not bear a
1
Al
1
304
1
St37
Copyright Pepperl+Fuchs
12 mm
n
≤ 3 V
d
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
≤ 25 mA
0
EN 60947-5-2:2007
IEC 60947-5-2:2007
60 V
i
800 V
imp
CCC marking because they do not require approval.
1