Inductive sensor
NJ5-18GK-N-5M
<Comfort series
<5 mm flush
<Usable up to SIL 2 acc. to IEC 61508
|
M18 X 1 |
|
|
<![if ! IE]> <![endif]>1 |
|
<![if ! IE]> <![endif]>4 4 |
<![if ! IE]> <![endif]>35.5 |
<![if ! IE]> <![endif]>39 |
|
24 |
|
|
General specifications |
|
|
|
|
|
|
<![if ! IE]> <![endif]>eng.pdf |
Switching function |
|
|
Normally closed (NC) |
|
||
Output type |
|
|
NAMUR |
|
|
|
|
<![if ! IE]> <![endif]>_ |
Installation |
|
sn |
flush |
|
|
|
<![if ! IE]> <![endif]>106446 |
|
|
|
|
|||
|
Rated operating distance |
5 mm |
|
|
|
||
<![if ! IE]> <![endif]>Filename: |
|
|
|
|
|
|
|
Reduction factor rAl |
|
sa |
0.4 |
|
|
|
|
|
Assured operating distance |
0 ... 4.05 mm |
|
|
|
||
<![if ! IE]> <![endif]>12-15 |
|
|
|
|
|
|
|
Reduction factor rCu |
|
|
0.3 |
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>- |
Reduction factor r304 |
|
|
0.85 |
|
|
|
<![if ! IE]> <![endif]>2020 |
|
|
|
|
|
||
Output type |
|
|
2-wire |
|
|
|
|
<![if ! IE]> <![endif]>ofissue: |
|
|
|
|
|
||
Nominal ratings |
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>Date15- |
Switching frequency |
|
f |
0 ... 500 Hz |
|
|
|
|
Nominal voltage |
|
Uo |
8.2 V (Ri approx. 1 kΩ) |
|
||
<![if ! IE]> <![endif]>-12 |
|
|
|
|
|
|
|
Hysteresis |
|
H |
typ. % |
|
|
|
|
<![if ! IE]> <![endif]>2020 |
|
|
|
|
|||
Current consumption |
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>date: |
|
|
|
|
|
|
|
Measuring plate not detected |
|
min. 3 mA |
|
|
|
||
<![if ! IE]> <![endif]>Release |
|
|
|
|
|||
Measuring plate detected |
|
≤ 1 mA |
|
|
|
||
|
|
|
|
|
|||
|
Refer to "General Notes Relating to Pepperl+Fuchs Product Information". |
|
|
|
1 |
||
|
Pepperl+Fuchs Group |
USA: +1 330 486 0001 |
Germany: +49 621 776 1111 |
Singapore: +65 6779 9091 |
|||
|
www.pepperl-fuchs.com |
fa-info@us.pepperl-fuchs.com |
fa-info@de.pepperl-fuchs.com |
fa-info@sg.pepperl-fuchs.com |
<![endif]>Release date: 2020-12-15 Date of issue: 2020-12-15 Filename: 106446_eng.pdf
Inductive sensor |
|
NJ5-18GK-N-5M |
|
|
Technical Data |
|
|
|
|
|
|
|
Functional safety related parameters |
|
|
|
MTTFd |
|
4566 a |
|
Mission Time (TM) |
|
20 a |
|
Diagnostic Coverage (DC) |
|
0 % |
|
Compliance with standards and directives |
|
|
|
Standard conformity |
|
|
|
NAMUR |
|
EN 60947-5-6:2000 |
|
|
|
IEC 60947-5-6:1999 |
|
Standards |
|
EN 60947-5-2:2007 |
|
|
|
EN 60947-5-2/A1:2012 |
|
|
|
IEC 60947-5-2:2007 |
|
|
|
IEC 60947-5-2 AMD 1:2012 |
|
Approvals and certificates |
|
|
|
IECEx approval |
|
|
|
Equipment protection level Gb |
|
IECEx PTB 11.0037X |
|
Equipment protection level Da |
|
IECEx PTB 11.0037X |
|
Equipment protection level Mb |
|
IECEx PTB 11.0037X |
|
ATEX approval |
|
|
|
Equipment protection level Gb |
|
PTB 00 ATEX 2048 X |
|
Equipment protection level Da |
|
PTB 00 ATEX 2048 X |
|
EAC conformity |
|
TR CU 012/2011 |
|
FM approval |
|
|
|
Control drawing |
|
116-0165 |
|
UL approval |
|
cULus Listed, General Purpose |
|
CSA approval |
|
cCSAus Listed, General Purpose |
|
CCC approval |
|
|
|
Hazardous Location |
|
2020322315002255 |
|
NEPSI approval |
|
|
|
NEPSI certificate |
|
GYJ16.1393X |
|
Ambient conditions |
|
|
|
Ambient temperature |
|
-25 ... 100 °C (-13 ... 212 °F) |
|
Mechanical specifications |
|
|
|
Connection type |
|
cable |
|
Housing material |
|
PBT/PPS |
|
Sensing face |
|
PBT |
|
Degree of protection |
|
IP66 / IP68 |
|
Cable |
|
|
|
Cable diameter |
|
6 mm ± 0.2 mm |
|
Bending radius |
|
> 10 x cable diameter |
|
Material |
|
PVC |
|
Core cross-section |
|
0.75 mm2 |
|
Length |
L |
5 m |
|
General information |
|
|
|
Use in the hazardous area |
|
see instruction manuals |
|
|
|
|
|
Connection |
|
|
BN
L+
BU
L-
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group |
USA: +1 330 486 0001 |
Germany: +49 621 776 1111 |
Singapore: +65 6779 9091 |
2 |
|
www.pepperl-fuchs.com |
fa-info@us.pepperl-fuchs.com |
fa-info@de.pepperl-fuchs.com |
fa-info@sg.pepperl-fuchs.com |
||
|