Pepperl Fuchs NJ50-FP-N-P4 Data Sheet

Inductive sensor NJ50-FP-N-P4
Technical Data
General specifications
Switching function Normally closed (NC) Output type NAMUR Rated operating distance sn50 mm Installation non-flush Assured operating distance sa0 ... 40.5 mm
0102
Model Number
NJ50-FP-N-P4
Features
• 50 mm non-flush
Reduction factor r Reduction factor rCu 0.3 Reduction factor r Output type 2-wire
Nominal ratings
Nominal voltage Uo8.2 V (Ri approx. 1 kΩ) Switching frequency f 0 ... 100 Hz Current consumption
Measuring plate not detected Measuring plate detected
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type screw terminals Information for connection A maximum of two conductors with the same core cross section
Core cross-section up to 2.5 mm
Minimum core cross-section
Maximum core cross-section Housing material PBT/metal Sensing face PBT Degree of protection IP67 Note Tightening torque: 1.8 Nm (housing)
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Standard conformity
NAMUR
Standards
Approvals and certificates
FM approval
Control drawing UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
Dimensions
0.4
Al
0.85
304
3 mA 1 mA
may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
without wire end ferrule 0.5 mm without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm
1G; 2G; 1D
EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
116-0165
2
80
2
, with connector sleeves 0.34 mm
2
2
40
7
1/2 NPT"
65
65
Ø5,3
11
Release date: 2017-11-15 13:03 Date of issue: 2018-02-16 106505_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NJ50-FP-N-P4
Electrical Connection
1
2
Equipment protection level Ga
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Appropriate type NJ 50-FP-N...
Effective internal inductivity C
Effective internal inductance L
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
Equipment protection level Gb
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012
Appropriate type NJ 50-FP-N...
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
Equipment protection level Da
CE marking 0102
i
i
i
i
L+
L-
The Ex-related marking can also be printed on the enclosed label.
Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
320 nF ; a cable length of 10 m is considered.
360 µH ; a cable length of 10 m is considered.
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Note:
Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already
been applied to the temperature table for category 1.
The Ex-related marking can also be printed on the enclosed label.
Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
320 nF ; a cable length of 10 m is considered.
360 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
ATEX marking ¬ II 1D Ex ia IIIC T135°C Da
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Appropriate type NJ 50-FP-N...
Effective internal inductivity C
Effective internal inductance L
i
i
The Ex-related marking can also be printed on the enclosed label.
Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
320 nF ; a cable length of 10 m is considered.
360 µH ; a cable length of 10 m is considered.
Release date: 2017-11-15 13:03 Date of issue: 2018-02-16 106505_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...