Inductive sensor |
NJ4-12GM50-WS-V13 |
|
|
|
|
Model Number
NJ4-12GM50-WS-V13
Features
•2-wire AC
Connection
2 L
3 N
1
Pinout
1
2 3
|
Wire colors |
|
|
|
|
1 |
|
GN/YE |
(green/yellow) |
|
|
|||
|
2 |
|
BN |
(brown) |
<![if ! IE]> <![endif]>eng.xml |
3 |
|
BU |
(blue) |
|
|
|
|
|
<![if ! IE]> <![endif]>026584 |
|
|
|
|
<![if ! IE]> <![endif]>03-27 |
Accessories |
|
||
<![if ! IE]> <![endif]>2013- |
|
|||
BF 12 |
|
|
||
<![if ! IE]> <![endif]>issue:ofDate |
|
|
||
Mounting flange, 12 mm |
|
|||
|
|
|||
<![if ! IE]> <![endif]>-03-27 09:59 |
|
|
|
|
<![if ! IE]> <![endif]>Release date: 2013 |
|
|
|
|
Subject to modifications without notice
Dimensions
|
M12x1 |
|
<![if ! IE]> <![endif]>5 |
<![if ! IE]> <![endif]>4 |
|
|
<![if ! IE]> <![endif]>38 |
17 |
<![if ! IE]> <![endif]>60 |
S |
|
|
LED |
Technical Data
General specifications |
|
|
|
Switching element function |
|
AC |
NO |
Rated operating distance |
sn |
4 mm |
|
Installation |
|
non-flush |
|
Output polarity |
|
AC |
|
Assured operating distance |
sa |
0 ... 3.24 mm |
|
Reduction factor rAl |
|
0.4 |
|
Reduction factor rCu |
|
0.4 |
|
Reduction factor r304 |
|
0.7 |
|
Nominal ratings |
|
|
|
Operating voltage |
UB |
20 ... 253 V |
|
Switching frequency |
f |
0 ... 20 Hz |
|
Voltage drop |
Ud |
typ. 4 V at 15 ... 200 mA |
|
|
|
typ. 6.5 V at 5 mA |
|
Momentary current |
|
0 ... 1200 mA |
|
(20 ms, 0.1 Hz) |
|
|
|
Operating current |
IL |
5 ... 200 mA |
|
Off-state current |
Ir |
typ. 0.7 mA |
|
Time delay before availability |
tv |
≤ 30 ms |
|
Switching state indication |
|
LED, yellow |
|
Ambient conditions |
|
|
|
|
|
|
|
Ambient temperature |
|
-25 ... 70 °C (-13 ... 158 °F) |
|
Mechanical specifications |
|
|
|
|
|
|
|
Connection type |
|
Connector M12 x 1 , 3-pin |
|
Housing material |
|
Stainless steel 1.4305 / AISI 303 |
|
Sensing face |
|
PBT |
|
Protection degree |
|
IP67 |
|
Note |
|
1) In the temperature range below 0 °C, permissible operating vol- |
|
|
|
tage Ub 80...253 V |
|
|
|
Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 |
|
|
|
Recommendation: after a short circuit, check that the device is |
|
|
|
functioning correctly. |
|
General information |
|
|
|
|
|
|
|
Scope of delivery |
|
2 self locking nuts in scope of delivery |
|
Compliance with standards and directives |
|
|
|
|
|
|
|
Standard conformity |
|
|
|
Standards |
|
EN 60947-5-2:2007 |
|
|
|
IEC 60947-5-2:2007 |
|
|
|
|
|
Approvals and certificates |
|
|
|
|
|
|
|
UL approval |
|
cULus Listed, General Purpose |
|
CSA approval |
|
cCSAus Listed, General Purpose |
|
|
|
|
|
CCC approval |
|
Certified by China Compulsory Certification (CCC) |
|
|
|
|
|
Copyright Pepperl+Fuchs
1