Inductive sensor NJ2-PD-E02-2.875-V95
Dimensions
LEDs
35
Ø48
2 x
Ø6.5
Ø31.75
Ø25
7/8"-16
Model Number
NJ2-PD-E02-2.875-V95
Cylinder Position Switch
Features
•4-wire DC
• Weld Immune
• Sensing range 2 mm
•3000 psi rating
Connection
1
2
4
5
L+
L-
Pinout
1
2
3
Wire colors
1 WH
2 RD
4 OR
5 BK
5
4
Accessories
V95-G-YE2M-STOOW
Female connector, 7/8" - 16 UNF, 5-pin, PUR cable
34.5
15.06
Ø12.7
37.5
26.5
"X"
Technical Data
General specifications
Switching element function NPN & PNP, NO
Rated operating distance s
Installation flush
Output polarity DC
Assured operating distance sa0 ... 1.62 mm
Reduction factor r
Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC
Switching frequency f 30 Hz
Hysteresis H 10 ... 20 typ. 15 %
Reverse polarity protection yes
Short-circuit protection yes
Voltage drop U
Operating current I
Off-state current I
No-load supply current I
Mag. Field strength, AC fields 250 mT
Mag. Field strength, DC fields 100 mT
Limit data
Operating pressure dynamically 3000 psi
Indicators/operating means
LED green Power on
LED yellow Output status
Standard conformity
Standards EN 60947-5-2
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Device connector 7/8"-16 UN , 5-pin
Protection degree IP67
Material Housing: zinc
Note X = 2.875 in (73 mm)
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
0.4
Al
0.85
304
2 mm
n
d
≤ 2 V DC
≤ 200 mA
L
r
≤ 100 µA
0
≤ 35 mA
Probe: aluminum
Release date: 2013-01-21 09:49 Date of issue: 2013-01-21 904491_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1

Inductive sensor NJ2-PD-E02-2.875-V95
NPT Type Mounting Holes:
1000 and 3000 psi NPT Types:
Mounting hole screw thread
shall be 1/4" - 20.
Minimum thread engagement
depth is 0.250" (6.35 mm)
Hole spacing is 35 mm
center to center.
Mounting Screws:
Standard 1000 and 3000 psi
models use two, self-locking 1/4"- 20 socket head cap
screws (provided).
Recommended tightening torque: 150 in lb (16.95 N-m).
Important: When using spacers, make
certain to maintain the 0.250" (6.35 mm) minimum
mounting screw thread engagement.
Sensor through-hole
Cylinder End-Cap Overhead View
Mounting
hole spacing
Mounting hole (x2)
Release date: 2013-01-21 09:49 Date of issue: 2013-01-21 904491_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
2