Pepperl Fuchs NJ2-F-US-1.025-V12 Data Sheet

Inductive sensor NJ2-F-US-1.025-V12
Technical Data
General specifications
Switching element function AC/DC NO
Model Number
NJ2-F-US-1.025-V12
Cylinder Position Switch
Features
• Sensing range 2 mm
• 1000 psi rating
•2-wire AC/DC
Accessories
V12-W-YE2M-PUR-H/S
Connecting cable, 1/2" - 20 UNF, 3-pin, irradiated PUR cable
SPACER 0.160 TO 0.375 : X.XXX"
Spacer for cylinder switches
SPACER 0.380 TO 0.875 : X.XXX"
Spacer for cylinder switches
Rated operating distance s Installation flush Output polarity AC/DC NO Assured operating distance sa0 ... 1.62 mm Reduction factor r Reduction factor r
Nominal ratings
Operating voltage UB20 ... 250 V AC/20 ... 300 V DC Switching frequency f 0 ... 20 Hz Hysteresis H 10 ... 20 % 15 typ. Reverse polarity protection yes Short-circuit protection yes Vol tag e d rop U
Momentary current (20 ms, 0.1 Hz) Operating current I Off-state current I Mag. Field strength, AC fields 250 mT Mag. Field strength, DC fields 100 mT
Limit data
Operating pressure dynamically 1000 psi
Indicators/operating means
LED green Power on LED red Output status LED red/green Short circuit/overload indication
Standa rd c on for mity
Stan dar ds EN 60947-5-2
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector 1/2"-20 UN , 3-pin Degree of protection IP67 Material Housing: zinc
Note X = 1.025 in (26 mm)
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose
0.4
Al
0.85
304
Dimensions
2 mm
n
d
7 V 3 A
8 ... 300 mA
L
< 1.7 mA
r
Probe: aluminum
LEDs
Ø48
35
Electrical Connection
2
3
1
Ø25
Ø11.5
2 x
Ø6.5
36
7
AC/DC
1/2"-20 UNF
31.5
23.5
"X"
Release date: 2015-04-09 17:41 Date of issue: 2015-04-09 906608_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NJ2-F-US-1.025-V12
Pinout
1
Wire colors
1 GN 2 RD/BK 3 RD/WH
2
3
(green) (red/black) (red/white)
NPT Type Mounting Holes: 1000 and 3000 psi NPT Types: Mounting hole screw thread shall be 1/4" - 20. Minimum thread engagement depth is 0.250" (6.35 mm) Hole spacing is 35 mm center to center.
Mounting Screws: Standard 1000 and 3000 psi models use two, self-locking 1/4"- 20 socket head cap screws (provided). Recommended tightening torque: 150 in lb (16.95 N-m).
Important: When using spacers, make certain to maintain the 0.250" (6.35 mm) minimum mounting screw thread engagement.
Sensor through-hole Mounting hole (x2)
Cylinder End-Cap Overhead View
Mounting
hole spacing
Release date: 2015-04-09 17:41 Date of issue: 2015-04-09 906608_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...