Pepperl Fuchs NJ2-F-E02-1.025-V1 Data Sheet

Inductive sensor NJ2-F-E02-1.025-V1
Dimensions
LEDs
Ø48
35
2 x
Ø6.5
38
Ø25
Model Number
NJ2-F-E02-1.025-V1
M12 x 1
34.5
26.5
7
"X"
Features
•4-wire DC
• Weld Immune
• Sensing range 2 mm
•1000 psi rating
Connection
1
4
2
3
L+
L-
Pinout
1
2
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
4
3
Ø11.5
Technical Data
General specifications
Switching element function NPN & PNP, NO Rated operating distance s Installation flush Output polarity switched high and switched low Assured operating distance sa0 ... 1.62 mm Reduction factor r Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC Switching frequency f 0 ... 30 Hz Hysteresis H 10 ... 20 typ. 15 % Reverse polarity protected yes Short-circuit protection yes Voltage drop U Operating current I Off-state current I No-load supply current I
Mag. Field strength, AC fields 250 mT Mag. Field strength, DC fields 100 mT
Limit data
Operating pressure dynamically 1000 psi
Indicators/operating means
LED green Power on LED yellow Output status
Standard conformity
Standards EN 60947-5-2
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Device connector M12 x 1 , 4-pin Protection degree IP67 Material Housing: zinc
Note X = 1.025 in (26 mm)
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose
0.4
Al
0.85
304
2 mm
n
2 V DC
d
200 mA
L
100 µA
r 0
35 mA
Probe: aluminum
Accessories
V1-G-2M-PVC
Cable socket, M12, 4-pin, PVC cable
V1-W-2M-PVC
Cable socket, M12, 4-pin, PVC cable
V1-G-2M-PUR H/S
Female cordset, M12, 4-pin, irradiated PUR cable
V1-W-2M-PUR H/S
Female cordset, M12, 4-pin, irradiated PUR cable
SPACER 0.160 TO 0.375 : X.XXX"
Release date: 2012-05-03 15:32 Date of issue: 2012-05-03 904474_eng.xml
Spacer for cylinder switches
Subject to modifications without notice Pepperl+Fuchs Group
Copyright Pepperl+Fuchs
1
Inductive sensor NJ2-F-E02-1.025-V1
NPT Type Mounting Holes:
1000 and 3000 psi NPT Types: Mounting hole screw thread shall be 1/4" - 20. Minimum thread engagement depth is 0.250" (6.35 mm) Hole spacing is 35 mm center to center.
Mounting Screws: Standard 1000 and 3000 psi models use two, self-locking 1/4"- 20 socket head cap screws (provided). Recommended tightening torque: 150 in lb (16.95 N-m).
Important: When using spacers, make certain to maintain the 0.250" (6.35 mm) minimum mounting screw thread engagement.
Sensor through-hole
Cylinder End-Cap Overhead View
Mounting
hole spacing
Mounting hole (x2)
Release date: 2012-05-03 15:32 Date of issue: 2012-05-03 904474_eng.xml
Subject to modifications without notice
2
Pepperl+Fuchs Group
Copyright Pepperl+Fuchs