Inductive sensor |
NJ25-50-E2 |
|
|
|
|
Model Number
NJ25-50-E2
Features
•25 mm non-flush
<![if ! IE]><![endif]>Release date: 2017-05-16 10:12 Date of issue: 2017-05-16 004412_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Technical Data
General specifications |
|
Normally open (NO) |
Switching function |
|
|
Output type |
sn |
PNP |
Rated operating distance |
25 mm |
|
Installation |
|
non-flush |
Output polarity |
sa |
DC |
Assured operating distance |
0 ... 20.25 mm |
|
Reduction factor rAl |
|
0.4 |
Reduction factor rCu |
|
0.3 |
Reduction factor r304 |
|
0.85 |
Output type |
|
3-wire |
Nominal ratings |
UB |
10 ... 30 V |
Operating voltage |
||
Switching frequency |
f |
0 ... 100 Hz |
Reverse polarity protection |
|
reverse polarity protected |
Short-circuit protection |
Ud |
pulsing |
Voltage drop |
≤ 3 V |
|
Operating current |
IL |
0 ... 200 mA |
No-load supply current |
I0 |
≤ 20 mA |
Functional safety related parameters |
1326 a |
|
MTTFd |
|
|
Mission Time (TM) |
|
20 a |
Diagnostic Coverage (DC) |
|
0 % |
Ambient conditions |
|
-25 ... 70 °C (-13 ... 158 °F) |
Ambient temperature |
|
|
Mechanical specifications |
|
cable PVC , 2 m |
Connection type |
|
|
Core cross-section |
|
0.75 mm2 |
Housing material |
|
PBT |
Sensing face |
|
PBT |
Degree of protection |
|
IP67 |
Compliance with standards and directives |
|
|
Standard conformity |
|
EN 60947-5-2:2007 |
Standards |
|
|
|
|
EN 60947-5-2/A1:2012 |
|
|
IEC 60947-5-2:2007 |
Approvals and certificates |
|
IEC 60947-5-2 AMD 1:2012 |
|
|
|
UL approval |
|
cULus Listed, General Purpose |
CSA approval |
|
cCSAus Listed, General Purpose |
Dimensions
<![if ! IE]><![endif]>40
<![if ! IE]><![endif]>5
82
50 |
<![if ! IE]> <![endif]>4,5 |
65
Electrical Connection
BN
L+
BK
BU
L-
1