Pepperl Fuchs NJ25-50-E2 Data Sheet

Inductive sensor NJ25-50-E2
General specifications
Switching function Normally open (NO) Output type PNP Rated operating distance sn25 mm Installation non-flush Output polarity DC
Model Number
NJ25-50-E2
Features
• 25 mm non-flush
Assured operating distance s Reduction factor rAl 0.4 Reduction factor r Reduction factor r Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 30 V Switching frequency f 0 ... 100 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Vol tag e d rop U Operating current I No-load supply current I
Functional safety related parameters
MTTFd 1326 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.75 mm Housing material PBT Sensing face PBT Degree of protection IP67
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose
0.3
Cu
0.85
304
0 ... 20.25 mm
a
3 V
d
0 ... 200 mA
L
20 mA
0
2
EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Dimensions
Electrical Connection
BN
BK
BU
40
5
82
50
65
4,5
L+
L-
Release date: 2017-05-16 10:12 Date of issue: 2017-05-16 004412_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Loading...