Pepperl Fuchs NJ15-30GK-SN Data Sheet

Inductive sensor NJ15-30GK-SN
Technical Data
General specifications
Switching function Normally closed (NC) Output type NAMUR with safety function Rated operating distance sn15 mm Installation non-flush Assured operating distance sa0 ... 12.15 mm
0102
Model Number
NJ15-30GK-SN
Features
• 15 mm non-flush
• Usable up to SIL 3 acc. to IEC 61508
Application
Danger!
In safety-related applications the sensor must be operated with a
qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety As­sessment" document which is available on
as an integral part
of this product’s documentation.
Accessories
BF 30
Mounting flange, 30 mm
Reduction factor r Reduction factor rCu 0.3 Reduction factor r Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications
Output type 2-wire
Nominal ratings
Installation conditions
A B C
F Nominal voltage Uo8 V DC Operating voltage U Switching frequency f 0 ... 100 Hz Current consumption
Measuring plate not detected
Measuring plate detected
Functional safety related parameters
MTTFd 9191 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type cable silicone , 2 m Core cross-section 0.75 mm Housing material PP Sensing face PP Degree of protection IP68 Cable
Bending radius
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Standard conformity
NAMUR
Standards
Approvals and certificates
FM approval
Control drawing UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
Dimensions
0.4
Al
0.85
304
B
the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida F ment" document which is available on as an integral part of this product's docume
18 mm 30 mm 45 mm 90 mm
5 ... 25 V
3 mA 1 mA
2
> 10 x cable diameter
1G; 2G; 3G; 1D; 3D
EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007
116-0165
Release date: 2016-11-07 09:49 Date of issue: 2018-02-28 106676_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
55
36
M30 x 1.5
1
34.5
40
1
Inductive sensor NJ15-30GK-SN
Electrical Connection
BN
BU
L+
L-
Installation Conditions
B F
metal-free zone
sensing face
support
Equipment protection level Ga
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Appropriate type NJ 15-30GK-SN...
Effective internal inductivity C
Effective internal inductance L
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
Special conditions
Equipment protection level Gb
CE marking 0102
i
i
The Ex-related marking can also be printed on the enclosed label.
Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
120 nF ; a cable length of 10 m is considered.
180 µH ; a cable length of 10 m is considered.
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Note:
Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already
been applied to the temperature table for category 1.
CA
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Appropriate type NJ 15-30GK-SN...
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
Special conditions
Equipment protection level Gc (ic)
Certificate PF13CERT2895 X
CE marking
i
i
The Ex-related marking can also be printed on the enclosed label.
Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
120 nF ; a cable length of 10 m is considered.
180 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Release date: 2016-11-07 09:49 Date of issue: 2018-02-28 106676_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.