Inductive sensor NJ1,5-18GM-N-D-V1
Technical Data
General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance sn1.5 mm
Installation flush
Assured operating distance sa0 ... 1.22 mm
0102
Model Number
NJ1,5-18GM-N-D-V1
Features
•1.5 mm flush
• Compression proof up to 350 bar,
dynamic on active surface
• Usable up to SIL 2 acc. to IEC 61508
Application
Note
Please refer to the technical information
about this product at www.pepperlfuchs.com. This information describes the
necessary geometry of the installation space!
Accessories
V1-G
Female connector, M12, 4-pin, field attachable
V1-W
Female connector, M12, 4-pin, field attachable
V1-W-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
V1-G-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
Reduction factor r
Reduction factor rCu 0
Reduction factor r
Output type 2-wire
Nominal ratings
Nominal voltage Uo8.2 V (Ri approx. 1 kΩ)
Switching frequency f 0 ... 400 Hz
Hysteresis H typ. %
Current consumption
Measuring plate not detected
Measuring plate detected
Limit data
Operating pressure 350 bar (5076.4 psi)
Functional safety related parameters
MTTFd 10887 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material Stainless steel 1.4305 / AISI 303
Sensing face Ceramic
Degree of protection IP67
Mass 41.81 g
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and
directives
Standard conformity
NAMUR
Standards
Approvals and certificates
EAC conformity TR CU 012/2011
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
Dimensions
0
Al
0.55
304
≥ 3 mA
≤ 1 mA
2G; 1D
EN 60947-5-6:2000
IEC 60947-5-6:1999
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
M18 x 1
ø 15 f9
0.1 A
Release date: 2018-06-20 08:07 Date of issue: 2018-06-20 106344_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical Connection
8
15
4
24
M12 x 1
14
1
2
L+
L-
35
45
1

Inductive sensor NJ1,5-18GM-N-D-V1
Pinout
1
2
4
3
Wire colors in accordance with EN 60947-5-6
1 BN
2 BU
Equipment protection level Gb
CE marking 0102
ATEX marking ¬ II 2G Ex ia IIC T6…T1 Gb The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Appropriate type NJ1,5-18GM-N-D..
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
Equipment protection level Da
CE marking 0102
i
i
(brown)
(blue)
Use is restricted to the following stated conditions
≤ 50 nF ; a cable length of 10 m is considered.
≤ 60 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
ATEX marking ¬ II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Appropriate type NJ1,5-18GM-N-D..
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
i
i
Use is restricted to the following stated conditions
≤ 50 nF ; a cable length of 10 m is considered.
≤ 60 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
surface temperature, and the effective internal reactance values can be found on the EC-type-examination
certificate.
The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of
the two values must be maintained.
Release date: 2018-06-20 08:07 Date of issue: 2018-06-20 106344_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2