Pepperl Fuchs NEB8-12GM50-E2-V1 Data Sheet

Inductive sensor NEB8-12GM50-E2-V1
Dimensions
M12 x 1
4
41
49
60
8
Model Number
NEB8-12GM50-E2-V1
Features
• 8 mm quasi flush
Connection
1
4
3
L+
L-
Pinout
1
2
4
3
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
Accessories
BF 12
Mounting flange, 12 mm
V1-G
4-pin, M12 female field-attachable connector
V1-W
4-pin, M12 female field-attachable connector
V1-G-2M-PUR
Cable socket, M12, 4-pin, PUR cable
V1-W-2M-PUR
Cable socket, M12, 4-pin, PUR cable
17
ø 10.5
LED (4x)
M12 x 1
Technical Data
General specifications
Switching element function PNP NO Rated operating distance s Installation quasi flush Output polarity DC Assured operating distance sa0 ... 6.48 mm Reduction factor r Reduction factor rCu 0.25 Reduction factor r Reduction factor r
Nominal ratings
Installation conditions
A B C
F Operating voltage U Switching frequency f 0 ... 400 Hz Hysteresis H 10 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Voltage drop Ud≤ 2 V Operating current I Off-state current I No-load supply current I Switching state indication LED, yellow
Functional safety related parameters
MTTFd 602 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Device connector M12 x 1 , 4-pin Housing material chromium plated brass Sensing face PBT Protection degree IP67 Protection class II Mass 34 g
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Products with a maximum operating voltage of 36 V do not bear a
0.3
Al
0.7
304
1
St37
) 20 a
M
8 mm
n
2 mm 14 mm 24 mm 46 mm 10 ... 30 V
B
0 ... 200 mA
L
0 ... 0.1 mA typ. 0.1 µA at 25 °C
r
10 mA
0
EN 60947-5-2:2007 IEC 60947-5-2:2007
CCC marking because they do not require approval.
Release date: 2013-01-29 13:59 Date of issue: 2013-01-29 212697_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1
Inductive sensor NEB8-12GM50-E2-V1
Installation conditions
B F
metal-free zone
sensing face
support
CA
Release date: 2013-01-29 13:59 Date of issue: 2013-01-29 212697_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
2
Loading...