Inductive sensor NEB3-F41-E2
Technical Data
General specifications
Switching element function PNP NO
Model Number
NEB3-F41-E2
Features
•3-wire DC
•Metal housing
•3 mm quasi flush
Rated operating distance s
Installation quasi flush
Output polarity DC
Assured operating distance sa0 ... 2.4 mm
Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Reduction factor rAl 0.35
Reduction factor r
Reduction factor r
Reduction factor r
Nominal ratings
Installation conditions
B
C
F
G
Operating voltage UB10 ... 30 V DC
Switching frequency f 0 ... 1000 Hz
Hysteresis H 2 ... 20 typ. 10 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Overload resistance yes
Wire breakage protection yes
Inductive overvoltage protection yes
Surge suppression yes
Ripple ≤ 10 %
Vol tag e d rop Ud≤ 2 V
Repeat accuracy R 0.15 mm
Operating current I
Off-state current I
No-load supply current I
Time delay before availability t
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 2134 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 85 °C (-13 ... 185 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PVC , 2 m
Core cross-section 0.14 mm
Housing material brass, nickel-plated
Sensing face PBT
Degree of protection IP67
Mass 50 g
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.3
Cu
0.7
304
0.45
Brass
) 20 a
M
3 mm
n
9 mm x 9 mm x 1 mm
6 mm
9 mm
16 mm
1 mm
0 ... 200 mA , above 50°C ≤ 150 mA
L
≤ 10 µA
r
≤ 15 mA
0
≤ 50 ms
v
2
EN 60947-5-2:2007
IEC 60947-5-2:2007
Release date: 2015-06-17 14:36 Date of issue: 2015-06-17 242305_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Dimensions
8
5
37
40
LED
3
1020
M3
1
Inductive sensor NEB3-F41-E2
Electrical Connection
Installation Conditions
BN
BK
BU
L+
L-
B F
metal-free zone
CG
support
Release date: 2015-06-17 14:36 Date of issue: 2015-06-17 242305_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2